计算扩散加权磁共振成像显示胰腺导管腺癌与局灶性自身免疫性胰腺炎的最佳目标b值
该回顾性研究纳入2012年4月至2017年1月共135例胰腺导管腺癌(n=111)或局灶性自身免疫性胰腺炎(n=24)患者,比较直接采集DWI与由b=0和1000 s/mm²生成的目标b值为1500、2000、3000 s/mm²的计算DWI对病灶显示的效能。结果显示cDWI1500或cDWI2000对显示胰腺导管腺癌和局灶性自身免疫性胰腺炎最有效,但cDWI1500的病灶信号强度比AUC显著低于cDWI2000和cDWI3000。
要点
- cDWI1500或cDWI2000对显示胰腺导管腺癌和局灶性自身免疫性胰腺炎最有效。
- cDWI2000上胰腺导管腺癌呈清晰高信号的发生率最高,其次为cDWI1500和cDWI3000。
- 随着b值升高,胰腺导管腺癌和局灶性自身免疫性胰腺炎的病灶信号强度比下降而对比度比升高。
核心结论
- 由b=0和1000 s/mm²生成的计算DWI中,cDWI1500或cDWI2000对显示胰腺导管腺癌和局灶性自身免疫性胰腺炎最有效。
- cDWI1500的病灶信号强度比AUC显著低于cDWI2000和cDWI3000(P < 0.001)。
研究设计与样本
- 回顾性研究,纳入2012年4月至2017年1月共135例患者,其中胰腺导管腺癌111例、局灶性自身免疫性胰腺炎24例。
- 所有患者接受b值为0、500、1000 s/mm²的DWI,并由b=0和b=1000图像生成目标b值为1500、2000、3000 s/mm²的计算DWI。
- 比较5种DWI方案(DWI500、DWI1000、cDWI1500、cDWI2000、cDWI3000)的病灶信号强度、图像质量、病灶和胰腺实质相对于脊髓的信号强度比以及病灶-胰腺实质对比度比。
- 对信号强度比进行受试者工作特征(ROC)分析。
关键影像表现/征象
- DWI500、DWI1000和cDWI1500的图像质量高于cDWI2000和cDWI3000(P < 0.001)。
- 胰腺导管腺癌呈清晰高信号的发生率在cDWI2000最高,其次为cDWI1500和cDWI3000(P < 0.001-0.002)。
- 局灶性自身免疫性胰腺炎呈清晰高信号的发生率在DWI1000、cDWI1500和cDWI2000高于DWI500和cDWI3000(P = 0.001-0.022)。
- 对于胰腺导管腺癌和局灶性自身免疫性胰腺炎,随着b值升高,信号强度比下降而对比度比升高。
诊断标准与关键数值
- cDWI1500的病灶信号强度比AUC显著低于cDWI2000和cDWI3000(P < 0.001)。
临床应用与阅片要点
- cDWI1500或cDWI2000有助于显示胰腺导管腺癌和局灶性自身免疫性胰腺炎,阅片时可结合目标b值选择。
- cDWI1500的病灶信号强度比AUC显著低于cDWI2000和cDWI3000,解读cDWI1500时需注意其信号强度比鉴别效能较低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare computed diffusion-weighted imaging (cDWI) feasibility with that of directly acquired DWI for visualizing pancreatic ductal adenocarcinoma (PDAC) and focal autoimmune pancreatitis (AIP).
METHODS: From April 2012 to January 2017, 135 patients with PDAC (n = 111) or focal AIP (n = 24) were retrospectively enrolled. They underwent DWI with b-values of 0, 500, and 1000 s/mm2. From DWI0 and DWI1000, we generated cDWIs with targeted b-values of 1500, 2000, and 3000 s/mm2. The lesions' signal intensities, image quality, signal intensity ratio (SIR) of lesions and pancreatic parenchyma to spinal cord, and lesion-to-pancreatic parenchyma contrast ratio (CR) were compared among the five DWI protocols (DWI500, DWI1000, cDWI1500, cDWI2000, and cDWI3000). SIR was analyzed by receiver operating characteristic (ROC) analyses.
RESULTS: DWI500, DWI1000, and cDWI1500 had higher image quality than cDWI2000 and cDWI3000 (P < 0.001). The incidence of clear hyperintense PDAC was highest on cDWI2000, followed by cDWI1500, and cDWI3000 (P < 0.001-0.002), while the incidence of clear hyperintense AIP was higher on DWI1000, cDWI1500, and cDWI2000 than on DWI500 and cDWI3000 (P = 0.001-0.022). SIRs decreased whereas CRs increased as the b-value increased, for both PDAC and AIP. The area under the ROC curve (AUC) of SIRlesion was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000 (P < 0.001).
CONCLUSION: cDWI1500 or cDWI2000 generated from b-values of 0 and 1000 s/mm2 were the most effective for visualizing PDAC and focal AIP; however, the SIRlesion AUC was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000.