文献速递神经MR

采用短重复时间绝热反转恢复预脉冲超短回波时间(STAIR-UTE)MRI序列在多发性硬化中进行人脑髓鞘成像

Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis.
PubMed 文献 · Radiology · 2020-08-11

该前瞻性研究在临床3-T扫描仪上验证短重复时间绝热反转恢复预脉冲超短回波时间(STAIR-UTE)序列抑制水信号并成像白质髓鞘超短T2质子的能力。10名健康志愿者和10例多发性硬化患者接受MRI检查,结果显示STAIR-UTE有效抑制水成分并选择性成像髓鞘,多发性硬化病灶髓鞘质子密度显著低于正常表现白质和健康志愿者正常白质。

要点

  • STAIR-UTE序列在3-T扫描仪上可有效抑制白质水信号并选择性成像髓鞘超短T2质子。
  • 多发性硬化病灶髓鞘质子密度显著降低,正常表现白质也有轻度降低。
  • 该序列为多发性硬化髓鞘损伤的 volumetric 成像提供新手段。

关键影像表现/征象

  • 三维STAIR-UTE序列有效抑制白质水成分并选择性成像髓鞘,志愿者研究中测得髓鞘T2*值为0.21毫秒±0.04。
  • 多发性硬化患者病灶超短回波时间髓鞘质子密度平均值为3.8 mol/L±1.5,正常表现白质为7.2 mol/L±0.8,健康志愿者正常白质为8.0 mol/L±0.8。
  • 多发性硬化病灶与正常表现白质分别和健康志愿者正常白质比较,P均<.001。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Water signal contamination is a major challenge for direct ultrashort echo time (UTE) imaging of myelin in vivo because water contributes most of the signals detected in white matter. Purpose To validate a new short repetition time (TR) adiabatic inversion recovery (STAIR) prepared UTE (STAIR-UTE) sequence designed to suppress water signals and to allow imaging of ultrashort T2 protons of myelin in white matter using a clinical 3-T scanner. Materials and Methods In this prospective study, an optimization framework was used to obtain the optimal inversion time for nulling water signals using STAIR-UTE imaging at different TRs. Numeric simulation and phantom studies were performed. Healthy volunteers and participants with multiple sclerosis (MS) underwent MRI between November 2018 and October 2019 to compare STAIR-UTE and a clinical T2-weighted fluid-attenuated inversion recovery sequence for assessment of MS lesions. UTE measures of myelin were also performed to allow comparison of signals in lesions and with those in normal-appearing white matter (NAWM) in patients with MS and in normal white matter (NWM) in healthy volunteers. Results Simulation and phantom studies both suggest that the proposed STAIR-UTE technique can effectively suppress long T2 tissues with a broad range of T1s. Ten healthy volunteers (mean age, 33 years ± 8 [standard deviation]; six women) and 10 patients with MS (mean age, 51 years ± 16; seven women) were evaluated. The three-dimensional STAIR-UTE sequence effectively suppressed water components in white matter and selectively imaged myelin, which had a measured T2* value of 0.21 msec ± 0.04 in the volunteer study. A much lower mean UTE measure of myelin proton density was found in MS lesions (3.8 mol/L ± 1.5), and a slightly lower mean UTE measure was found in NAWM (7.2 mol/L ± 0.8) compared with that in NWM (8.0 mol/L ± 0.8) in the healthy volunteers (P < .001 for both comparisons). Conclusion The short repetition time adiabatic inversion recovery-prepared ultrashort echo time sequence provided efficient water signal suppression for volumetric imaging of myelin in the brain and showed excellent myelin signal contrast as well as marked ultrashort echo time signal reduction in multiple sclerosis lesions and a smaller reduction in normal-appearing white matter compared with normal white matter in volunteers. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Messina and Port in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Ma YJ, Jang H, Wei Z, et al. Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis. Radiology. 2020. PMID: 32779970. doi:10.1148/radiol.2020200425

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。