血管迂曲度的半自动测量及其对机械取栓操作的影响
研究连续纳入100例前循环大血管闭塞取栓患者,对主动脉弓至颈内动脉终点的导管路径行半自动三维分段,测量迂曲指数与成角。发现颈总动脉成角左右侧存在显著差异,颈总动脉与颅外颈内动脉迂曲度与年龄、穿刺至闭塞部位时间及透视时间相关。
要点
- 颈总动脉与颅外颈内动脉迂曲度与年龄、穿刺至闭塞时间及透视时间相关。
- 颈总动脉成角模式左右侧存在显著差异。
- 严重成角在颈总动脉占5.8%、颅外颈内动脉占39.4%。
核心结论
- 颈总动脉成角在左右侧之间存在显著差异。
- 颅外颈总动脉与颈内动脉的迂曲指数与年龄相关,并影响穿刺至闭塞部位时间及总透视时间。
研究设计与样本
- 研究类型为连续纳入100例前循环大血管闭塞取栓患者、观察期12个月的研究。
- 采用CT血管造影(CTA)对主动脉弓至颈内动脉终点的导管路径行三维分段,半自动测量迂曲指数与成角。
- 共分析100例患者的188条导管路径。
诊断标准与关键数值
- 严重成角定义为≤30°,颈总动脉中占5.8%、颅外颈内动脉中占39.4%。
- 5条路径(2.6%)存在360°环。
- 颈总动脉迂曲指数右侧0.20±0.086 vs 左侧0.15±0.82,差异有统计学意义(p值<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Few studies have examined the geometry of endovascular mechanical thrombectomy pathways. Here we examine the tortuosity and angulations of catheter pathways from the aortic arch to the termination of the internal carotid artery (ICA) and its association with thrombectomy performance.
METHODS: We included 100 consecutive anterior circulation large vessel occlusion thrombectomy patients over 12 months. Computed tomography angiograms (CTA) were used for 3D segmentation of catheter pathway from the aortic arch to ICA termination. Tortuosity index (TI) and angulations of the catheter pathway were measured in a semi-automated fashion. TI and angulation degree were compared between sides and correlated with age and procedural measures.
RESULTS: We analyzed 188 catheter pathways in 100 patients. Severe angulation (≤ 30°) was present in 5.8% and 39.4% of common carotid artery (CCA) and extracranial ICA segments, respectively. Five pathways (2.6%) had 360° loop. CCA and extracranial ICA tortuosity had a weak but significant correlation with age (r = 0.17, 0.21, p value = 0.05, 0.02 respectively), time from groin puncture to the site of occlusion (r = 0.29, 0.25, p values = 0.008, 0.026 respectively), and fluoroscopy time (r = 0.022, 0.31, p values = 0.016, 0.001 respectively). There was a significant difference in the pattern of angulation (p value = 0.04) and tortuosity between right and left side in CCA segment (TI = 0.20 ± 0.086 vs. 0.15 ± 0.82, p value < 0.001).
CONCLUSIONS: There was a significant difference in CCA angulation between right and left sides. TI of extracranial CCA and ICA correlated with age and influenced time from groin puncture to the occlusion site and total fluoroscopy time.
引用
- Mokin M, Waqas M, Chin F, et al. Semi-automated measurement of vascular tortuosity and its implications for mechanical thrombectomy performance. Neuroradiology. 2020. PMID: 32816090. doi:10.1007/s00234-020-02525-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。