基于T1的合成磁共振对比改善7T下的多发性硬化与局灶性癫痫成像
本研究回顾性纳入21例不同表型多发性硬化患者和35例局灶性癫痫患者,在7T磁共振系统上使用MP2RAGE序列生成基于T1的合成对比图像,并由4名放射科医生与常规图像比较信号均匀性、对比强度和病灶可视化。合成图像在全部3项标准上评分均高于常规图像(P < 0.0001),仅3例癫痫患者合成图像评分略低但不妨碍病灶识别;作者认为该技术可提供按需对比并缩短检查总时间。
要点
- 7T MP2RAGE生成的T1合成对比在信号均匀性、对比强度和病灶显示上均优于常规图像。
- 4名阅片医生对任何合成图像均未评为「明显更差」,仅3例癫痫患者合成图像评分略低但不影响病灶识别。
- 合成对比可按需生成,免除额外序列,从而缩短磁共振检查总时长。
关键影像表现/征象
- 合成图像在信号均匀性、对比强度和病灶可视化3项定性标准上的放射学质量评分均高于常规图像,差异均有统计学意义(P < 0.0001,Wilcoxon秩和检验)。
- 无论对比类型、病变种类或阅片者如何,合成图像评分均更高。
- 4名放射科医生中无人将任何合成图像评为「明显更差」。
- 仅3例癫痫患者的合成图像评分略低,但未妨碍病灶识别。
诊断标准与关键数值
- 由4名放射科医生按信号均匀性、对比强度和病灶可视化3项定性标准评估图像质量。
- 合成图像与常规MP2RAGE图像在全部3项标准上差异均有统计学意义(P < 0.0001,Wilcoxon秩和检验)。
- 计算了观察者内和观察者间信度。
临床应用与阅片要点
- 7T MP2RAGE可生成按需T1合成对比,阅片时可用于多发性硬化和局灶性癫痫的病灶显示。
- 合成图像可替代额外序列,有助于缩短磁共振检查总时长。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Ultra-high field magnetic resonance imaging (MRI) (≥7 T) is a unique opportunity to improve the clinical diagnosis of brain pathologies, such as multiple sclerosis or focal epilepsy. However, several shortcomings of 7 T MRI, such as radiofrequency field inhomogeneities, could degrade image quality and hinder radiological interpretation. To address these challenges, an original synthetic MRI method based on T1 mapping achieved with the magnetization-prepared 2 rapid acquisition gradient echo (MP2RAGE) sequence was developed. The radiological quality of on-demand T1-based contrasts generated by this technique was evaluated in multiple sclerosis and focal epilepsy imaging at 7 T.
MATERIALS AND METHODS: This retrospective study was carried out from October 2017 to September 2019 and included 21 patients with different phenotypes of multiple sclerosis and 35 patients with focal epilepsy who underwent MRI brain examinations using a whole-body investigative 7 T magnetic resonance system. The quality of 2 proposed synthetic contrast images were assessed and compared with conventional images acquired at 7 T using the MP2RAGE sequence by 4 radiologists, evaluating 3 qualitative criteria: signal homogeneity, contrast intensity, and lesion visualization. Statistical analyses were performed on reported quality scores using Wilcoxon rank tests and further multiple comparisons tests. Intraobserver and interobserver reliabilities were calculated as well.
RESULTS: Radiological quality scores were reported higher for synthetic images when compared with original images, regardless of contrast, pathologies, or raters considered, with significant differences found for all 3 criteria (P < 0.0001, Wilcoxon rank test). None of the 4 radiologists ever rated a synthetic image "markedly worse" than an original image. Synthetic images were rated slightly less satisfying for only 3 epileptic patients, without precluding lesion identification.
CONCLUSION: T1-based synthetic MRI with the MP2RAGE sequence provided on-demand contrasts and high-quality images to the radiologist, facilitating lesion visualization in multiple sclerosis and focal epilepsy, while reducing the magnetic resonance examination total duration by removing an additional sequence.
引用
- Massire A, Seiler C, Troalen T, et al. T1-Based Synthetic Magnetic Resonance Contrasts Improve Multiple Sclerosis and Focal Epilepsy Imaging at 7 T. Invest Radiol. 2021. PMID: 32852445. doi:10.1097/RLI.0000000000000718
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。