文献速递妇产影像神经儿科影像MRUS

胎儿-胎盘血流与儿童期神经发育:基于人群的神经影像学研究

Fetal-placental blood flow and neurodevelopment in childhood: population-based neuroimaging study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-01-01

在Generation R队列2803例妊娠中,孕中晚期脐动脉搏动指数(UA-PI)与儿童期认知、运动能力及脑形态的关联显示:孕晚期UA-PI每升高1个标准差,手指敲击测试少0.41次(95%CI 0.11-0.70)、平衡木测试少0.64步(95%CI 0.20-1.08);孕晚期UA-PI与IQ的关联在多重检验校正后未持续。作者认为胎盘血管阻力升高可能对学龄期神经发育有轻度不良影响,鼓励未来研究早期循环在脑发育中的作用。

要点

  • 孕晚期UA-PI每升高1个标准差,儿童精细运动(手指敲击)少0.41次(95%CI 0.11-0.70)。
  • 孕晚期UA-PI每升高1个标准差,儿童粗大运动(平衡木)少0.64步(95%CI 0.20-1.08)。
  • 孕中期UA-PI每升高1个标准差与脑体积减小6.1 cm³(95%CI 1.0-11.3)相关,但多重检验校正后未持续。

核心结论

  • 胎盘血管阻力升高可能对学龄期神经发育结局有轻度不良影响;这些效应在人群水平上是细微的,作者鼓励未来研究早期循环在脑发育中的作用,该信息可用于制定针对性干预措施。

研究设计与样本

  • 基于人群的纵向队列研究,纳入Generation R研究中2803例妊娠,测量孕中晚期脐动脉搏动指数(UA-PI)。
  • 儿童4-8岁接受非言语智力测试,8-12岁接受手指敲击测试(精细运动)、平衡木测试(粗大运动)及脑磁共振成像。
  • 采用线性回归评估产前UA-PI与神经发育结局的关系,校正儿童年龄和性别、母亲年龄、教育程度、产次及吸烟状态。

关键影像表现/征象

  • 孕晚期UA-PI每升高1个标准差,手指敲击测试少0.41次(95%CI 0.11-0.70),平衡木测试少0.64步(95%CI 0.20-1.08)。
  • 孕晚期UA-PI每升高1个标准差与IQ低0.65分(95%CI 0.04-1.25)相关,但多重检验校正后未持续。
  • 孕中期UA-PI每升高1个标准差与脑体积减小6.1 cm³(95%CI 1.0-11.3)相关,但多重检验校正后未持续。

临床应用与阅片要点

  • 作者结论指出胎盘血管阻力升高可能对学龄期神经发育有轻度不良影响,并鼓励未来研究早期循环在脑发育中的作用。

局限性

  • 孕晚期UA-PI与IQ的关联在多重检验校正后未持续。
  • 孕中期UA-PI与脑体积的关联在多重检验校正后未持续。
  • 作者在结论中表示鼓励未来研究早期循环在脑发育中的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Antenatal Doppler measurements of the fetal umbilical and cerebral circulations can predict perinatal complications; however, it is unclear if subtle variations in antenatal Doppler measurements are associated with long-term neurodevelopmental outcome. In this study, we examined whether antenatal Doppler measurements of the fetal-placental circulation are associated with cognitive and motor abilities and brain morphology in childhood.

METHODS: To evaluate differences in long-term sequelae across the continuum of the umbilical and cerebral artery circulations in the general population, we utilized a population-based longitudinal cohort study approach. In women from the Generation R study, we measured second- and third-trimester umbilical artery pulsatility index (UA-PI). Children underwent non-verbal intelligence testing at 4-8 years of age, and at 8-12 years they underwent finger-tapping tests to measure fine motor skills, balance beam tests to measure gross motor skills and brain magnetic resonance imaging. We assessed the relationships between prenatal UA-PI and neurodevelopmental outcome using linear regression. We adjusted for child age and sex, maternal age, education, parity and smoking status.

RESULTS: The study sample included 2803 pregnancies. Higher third-trimester UA-PI was associated with poorer fine motor performance (0.41 (95% CI, 0.11-0.70) fewer taps on the finger-tapping test per 1 SD higher UA-PI) and gross motor performance (0.64 (95% CI, 0.20-1.08) fewer steps on the balance beam test per 1 SD higher UA-PI). One SD higher third-trimester UA-PI was also associated with 0.65 (95% CI, 0.04-1.25) points lower intelligence quotient; however, unlike the associations with motor abilities, this finding did not persist after correction for multiple testing. Higher second-trimester UA-PI was associated with smaller brain volume (6.1 (95% CI, 1.0-11.3) cm3 reduction per 1 SD higher UA-PI), but the association did not persist after correction for multiple testing.

CONCLUSION: Higher placental vascular resistance may have mild adverse effects on neurodevelopmental outcome at school age. While these effects are subtle at population level, we encourage future research into the role of early circulation in brain development. This information could be used to develop targeted interventions. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Sammallahti S, Tiemeier H, Louwen S, et al. Fetal-placental blood flow and neurodevelopment in childhood: population-based neuroimaging study. Ultrasound Obstet Gynecol. 2021. PMID: 32851732. doi:10.1002/uog.22185

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。