平扫CT诊断脑静脉窦血栓形成的准确性
回顾性纳入48例脑静脉窦血栓形成(CVT)患者与48例健康对照,评估平扫脑CT(NECT)识别CVT的诊断效能。两位放射科医师独立评估窦高密度,一致性好(k=0.64);窦高密度诊断CVT的敏感度81%、特异度77%、PPV 78%、NPV 80%。CVT受累窦段平均衰减值高于通畅窦段(62.4±10 vs 55.6±6 HU,p<0.0001),ROC分析显示63 HU cutoff的敏感度52%、特异度88%。
要点
- 平扫CT上窦高密度诊断CVT的敏感度81%、特异度77%,可作为提示征象。
- CVT受累窦段平均衰减值62.4±10 HU,高于通畅窦段55.6±6 HU(p<0.0001)。
- 63 HU cutoff可提高特异度至88%,但敏感度降至52%。
关键影像表现/征象
- 平扫CT上窦高密度的观察者间一致性良好(k=0.64)。
- CVT受累窦段平均衰减值为62.4±10 HU,通畅窦段为55.6±6 HU,前者显著高于后者(p<0.0001)。
- 血细胞比容值与通畅窦段衰减值显著相关(r=0.19)。
诊断标准与关键数值
- 平扫CT窦高密度诊断CVT的敏感度81%、特异度77%、PPV 78%、NPV 80%。
- ROC分析显示窦衰减值63 HU cutoff检测CVT的敏感度52%、特异度88%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the diagnostic performance of unenhanced brain CT (NECT) in identifying patients with cerebral venous sinus thrombosis (CVT).
METHODS: Forty-eight consecutive patients with CVT and 48 healthy controls were included in our retrospective study. All patients underwent NECT and CT/MR angiography within 24 h. Two radiologists independently evaluated NECT images for the presence of sinus hyperdensity; discrepancies were solved by consensus. Sinus attenuation was measured in seven sites. The obtained data were compared with the presence of CVT at CT/MR angiography and with patients' hematocrit.
RESULTS: Interobserver agreement in sinus hyperdensity detection was good (k = 0.64). The presence of sinus hyperdensity at NECT enabled to detect patients with CVT with 81% sensitivity, 77% specificity, 78% PPV, and 80% NPV. Mean attenuation was significantly higher in sinus segments involved by CVT than in patent ones (62.4 ± 10 versus 55.6 ± 6 HU, p < 0.0001). ROC analysis showed that a cutoff value of 63 HU enables to detect patients with CVT with 52% sensitivity and 88% specificity. Hematocrit values were significantly correlated with patent sinus segments attenuation (r = 0.19).
CONCLUSIONS: The presence of sinus hyperdensity at NECT enables to detect patients with CVT with 81% sensitivity and 77% specificity. A sinus attenuation cutoff value of 63 HU can be used in order to increase specificity, but lowering sensitivity.
引用
- Bonatti M, Valletta R, Lombardo F, et al. Accuracy of unenhanced CT in the diagnosis of cerebral venous sinus thrombosis. Radiol Med. 2020. PMID: 32833197. doi:10.1007/s11547-020-01263-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。