指南与共识骨肌介入技术与安全CT

在真实模拟环境中培训CT引导下神经根周围治疗——评估及培训课程建议

Training of CT-guided Periradicular Therapy in a Realistic Simulation Environment - Evaluation and Recommendations for a Training Curriculum.
指南 / 共识 · Acad Radiol · 2020-08-14

研究用含3D打印患者模拟体模的新型模拟环境培训17名医学生对腰椎行CT引导下神经根周围治疗,共三次训练(第0天、第7天及第28天后),每次6例操作。结果显示操作时长和透视采集次数在首次训练后下降(p<0.001)且此后无进一步改善(p>0.6),第二场次表现评分接近满分(均值5.7;95%CI:5.5-6.0;p<0.001),第三场次又下降(均值4.9;95%CI:4.6-5.3;p=0.008)。作者认为模拟培训有效,理想安排为在治疗首例患者前不久进行一次含五例操作的训练。

要点

  • 操作时长和透视采集次数在首次训练后即下降(p<0.001),此后无进一步改善(p>0.6)。
  • 各场次内操作时长和采集次数随操作例数增加而下降,均在完成五例操作后最低。
  • 表现评分第二场次接近满分(均值5.7;95%CI:5.5-6.0),第三场次下降至均值4.9(95%CI:4.6-5.3;p=0.008)。

核心结论

  • 在真实模拟环境中进行CT引导下神经根周围治疗的模拟培训是有效的。
  • 理想安排为在治疗首例患者前不久进行一次含五例操作的训练。

研究设计与样本

  • 研究类型为培训评估研究,使用含3D打印患者模拟体模的新型模拟环境。
  • 样本为17名医学生,接受三次训练(第0天、第7天及第28天后),每次训练含六例CT引导下腰椎神经根周围治疗操作。
  • 由独立研究者采用六点检查表评分(0为最低,6为最高)评估表现,并记录操作时长和透视图像采集次数。
  • 参与者通过问卷自评技能和模拟训练。

诊断标准与关键数值

  • 使用六点检查表评分,0分为最低、6分为最高。
  • 第二场次表现评分均值5.7(95%CI:5.5-6.0;p<0.001)。
  • 第三场次表现评分均值4.9(95%CI:4.6-5.3;p=0.008)。

临床应用与阅片要点

  • 模拟培训中操作时长和透视采集次数在首次训练后即下降(p<0.001),此后无进一步改善(p>0.6)。
  • 各场次内操作时长和采集次数随操作例数增加而下降,均在完成五例操作后最低。
  • 作者认为模拟培训有效,理想安排为在治疗首例患者前不久进行一次含五例操作的训练。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the training of computed tomography (CT)-guided periradicular therapy in a realistic simulation environment and to derive recommendations for a training curriculum.

MATERIALS AND METHODS: A novel simulation environment including the use of a 3D printed, patient-mimicking phantom was used to train medical students to perform CT-guided periradicular therapy of the lumbar spine. Seventeen participants underwent three training sessions (day 0, day 7, and after day 28) with six procedures per session. Procedure duration and the number of fluoroscopy image acquisitions were recorded. Participants' performance was assessed by an independent investigator using a six-point checklist scale (0 = lowest, 6 = highest). In addition, participants self-evaluated their skills and the simulation training in questionnaires.

RESULTS: Procedure durations and image acquisitions decreased after one training session (p < 0.001) without further improvement thereafter (p > 0.6). They also decreased within training sessions and were lowest after five procedures in all sessions. Performance scores improved after the first session to nearly perfect scores in the second session (mean 5.7; 95%CI: 5.5-6.0; p < 0.001) and decreased again in the third session (mean 4.9; 95%CI: 4.6-5.3; p = 0.008). Participants were satisfied with their training progress and felt adequately prepared to perform CT-guided periradicular therapies on patients after the training.

CONCLUSION: Simulation-based training of CT-guided periradicular therapy in a realistic environment is effective and should ideally be performed with one training session consisting of five procedures shortly before treating the first patient.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Braun VPB, Nunninger M, Hamm B, et al. Training of CT-guided Periradicular Therapy in a Realistic Simulation Environment - Evaluation and Recommendations for a Training Curriculum. Acad Radiol. 2020. PMID: 32807605. doi:10.1016/j.acra.2020.07.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。