基于人工智能算法在CT肺动脉造影中自动检测肺栓塞
本研究回顾性纳入本院2017年1499例CT肺动脉造影(CTPA),以最终书面报告为参考标准,评估基于深度卷积神经网络(Resnet架构)的肺栓塞自动检测原型算法。该算法在患者水平敏感度92.7%(95%CI 88.3-95.5%)、特异度95.5%(95%CI 94.2-96.6%);作者结论认为该AI原型算法对CTPA上肺栓塞检测具有高度诊断准确性,敏感度与特异度均衡。
要点
- AI原型算法检测肺栓塞患者水平敏感度92.7%、特异度95.5%。
- 假阳性主要来自对比剂相关血流伪影、肺静脉和淋巴结。
- 作者认为该算法可作为二次阅片工具并帮助自动优先处理高度疑似肺栓塞的检查。
核心结论
- 所测试的AI原型算法对CTPA上肺栓塞检测具有高度诊断准确性,敏感度与特异度均衡,这是其临床有用性的前提。
- 作者认为该算法可帮助临床医生自动优先处理高度疑似肺栓塞的检查,并作为二次阅片工具。
研究设计与样本
- 回顾性识别本院2017年所有CTPA共1499例,排除临床问题非肺栓塞的检查34例。
- 剩余检查依据最终书面报告分为肺栓塞阳性232例和阴性1233例,最终书面报告定义为参考标准。
- 输入为完全匿名化的1 mm软组织重建系列,算法为基于Resnet架构的深度卷积神经网络肺栓塞检测原型。
- 算法在其他机构采集的28000例CTPA上训练和验证,结果系列通过基于网络的反馈平台复核。
- 诊断性能在患者水平和病灶水平分别计算。
关键影像表现/征象
- 算法正确识别232例肺栓塞阳性中的215例,敏感度92.7%(95%CI 88.3-95.5%)。
- 算法正确识别1233例肺栓塞阴性中的1178例,特异度95.5%(95%CI 94.2-96.6%)。
- 病灶水平上,算法标记为栓子的1352个病灶中1174个为真栓子。
- 假阳性病灶大多由对比剂相关血流伪影、肺静脉和淋巴结所致。
诊断标准与关键数值
- 患者水平敏感度92.7%(95%CI 88.3-95.5%),特异度95.5%(95%CI 94.2-96.6%),参考标准为最终书面报告。
- 病灶水平上算法标记的1352个栓子病灶中1174个为真栓子。
临床应用与阅片要点
- 作者认为该算法可自动优先处理高度疑似肺栓塞的检查,并作为二次阅片工具。
- 作者认为通过补充放射科传统的工作列表优先排序方式,可加速肺栓塞患者的诊断和治疗流程并帮助避免假阴性报告。
- 阅片时需注意对比剂相关血流伪影、肺静脉和淋巴结是算法假阳性的主要来源。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the performance of an AI-powered algorithm for the automatic detection of pulmonary embolism (PE) on chest computed tomography pulmonary angiograms (CTPAs) on a large dataset.
METHODS: We retrospectively identified all CTPAs conducted at our institution in 2017 (n = 1499). Exams with clinical questions other than PE were excluded from the analysis (n = 34). The remaining exams were classified into positive (n = 232) and negative (n = 1233) for PE based on the final written reports, which defined the reference standard. The fully anonymized 1-mm series in soft tissue reconstruction served as input for the PE detection prototype algorithm that was based on a deep convolutional neural network comprising a Resnet architecture. It was trained and validated on 28,000 CTPAs acquired at other institutions. The result series were reviewed using a web-based feedback platform. Measures of diagnostic performance were calculated on a per patient and a per finding level.
RESULTS: The algorithm correctly identified 215 of 232 exams positive for pulmonary embolism (sensitivity 92.7%; 95% confidence interval [CI] 88.3-95.5%) and 1178 of 1233 exams negative for pulmonary embolism (specificity 95.5%; 95% CI 94.2-96.6%). On a per finding level, 1174 of 1352 findings marked as embolus by the algorithm were true emboli. Most of the false positive findings were due to contrast agent-related flow artifacts, pulmonary veins, and lymph nodes.
CONCLUSION: The AI prototype algorithm we tested has a high degree of diagnostic accuracy for the detection of PE on CTPAs. Sensitivity and specificity are balanced, which is a prerequisite for its clinical usefulness.
KEY POINTS: • An AI-based prototype algorithm showed a high degree of diagnostic accuracy for the detection of pulmonary embolism on CTPAs. • It can therefore help clinicians to automatically prioritize exams with a high suspection of pulmonary embolism and serve as secondary reading tool. • By complementing traditional ways of worklist prioritization in radiology departments, this can speed up the diagnostic and therapeutic workup of patients with pulmonary embolism and help to avoid false negative calls.
引用
- Weikert T, Winkel DJ, Bremerich J, et al. Automated detection of pulmonary embolism in CT pulmonary angiograms using an AI-powered algorithm. Eur Radiol. 2020. PMID: 32621243. doi:10.1007/s00330-020-06998-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。