PubMed 文献 · J Ultrasound Med · 2020-07-24

研究纳入451例至少一侧颈内动脉直径狭窄>40%的患者,在609条动脉上比较灰度、彩色多普勒和能量多普勒测量的颈内动脉横截面积。彩色多普勒测值显著大于能量多普勒和灰度,后两者无显著差异;该差异在评估狭窄时应予考虑。

要点

  • 彩色多普勒测得的颈内动脉横截面积显著大于能量多普勒和灰度测值。
  • 灰度和能量多普勒的横截面积测值无显著差异。
  • 较小管腔直径(<60 mm²)时彩色多普勒相对高估更明显,平均高9.4%。

关键影像表现/征象

  • 灰度、能量多普勒和彩色多普勒测量的颈内动脉横截面积均值±标准差分别为122±81、122±79和125±79 mm²。
  • 彩色多普勒估算的平均颈内动脉面积显著大于能量多普勒(P<.0001)和灰度(P=.02)。
  • 灰度和能量多普勒图像的面积估算无显著差异(P=.99)。

诊断标准与关键数值

  • 校正单血管内重复测量的相关性后,彩色多普勒管腔面积估算值平均比灰度大3.44 mm²、比能量多普勒大9.5 mm²。
  • 较小管腔直径(<60 mm²)时,彩色多普勒的相对横截面积估算值平均比大管腔直径时大9.4%。

临床应用与阅片要点

  • 在通过管腔测量确认或分级狭窄时,应考虑彩色多普勒测得的颈内动脉横截面积显著大于能量多普勒和灰度测值这一差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine how measurements of the internal carotid artery (ICA) cross-sectional area will differ systematically when obtained by grayscale, color Doppler, and power Doppler imaging.

METHODS: A total of 451 patients had greater than 40% diameter stenosis in at least a single ICA. Anteroposterior and transverse luminal diameters were measured in 609 arteries on grayscale, color, and power Doppler transverse images of the carotid bulb and proximal and distal ICAs. Cross-sectional areas were calculated and compared by a repeated-measures analysis of variance model to assess for significant differences.

RESULTS: Mean ICA cross-sectional areas ± SDs as measured by grayscale, power Doppler, and color Doppler imaging were 122 ± 81, 122 ± 79, and 125 ± 79 mm2 , respectively. The mean ICA area estimated by color Doppler imaging was significantly greater than that estimated by power Doppler imaging (P < .0001) and grayscale imaging (P = .02). Area estimates on grayscale and power Doppler images were not significantly different (P = .99). After accounting for the correlation of repeated measurements within single vessels, color Doppler estimates of the luminal area were on average 3.44 and 9.5 mm2 greater than grayscale and power Doppler estimates. Relative cross-sectional area estimates were on average 9.4% greater with color Doppler imaging at smaller luminal diameters (<60 mm2 ) compared with larger luminal diameters.

CONCLUSIONS: Measurements of the ICA cross-sectional area by color Doppler imaging were significantly greater than those obtained by power Doppler or grayscale imaging. This difference should be considered when stenosis estimates are confirmed or graded by luminal measurements.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Kliewer MA, Lee LJ, Bagley AR, et al. Measurement of the Internal Carotid Artery Cross-Sectional Area: Systematic Differences Depending on Grayscale, Power Doppler, and Color Doppler Techniques. J Ultrasound Med. 2020. PMID: 32706144. doi:10.1002/jum.15400

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。