文献速递儿科影像骨肌神经CT

CT上颅颈测量对识别儿童部分或完全性颅颈韧带损伤的准确性

Accuracy of craniocervical measurements on CT for identifying partial or complete craniocervical ligament injuries in pediatric patients.
PubMed 文献 · Skeletal Radiol · 2020-07-21

该病例对照回顾性研究评估了CT颅颈测量对≤16岁儿童颅颈交界区损伤的识别准确性。完全性断裂损伤中C1-C2距离、寰枕距离和基底-齿突距离的AUC达0.90-0.98,准确性优;而部分断裂损伤中仅基底-齿突距离AUC=0.75准确性尚可。主观征象在损伤患者中常见,可提高识别敏感性。

要点

  • 完全性断裂损伤中,C1-C2距离、寰枕距离和基底-齿突距离的AUC为0.90-0.98,诊断准确性优。
  • 部分断裂损伤中,仅基底-齿突距离AUC=0.75准确性尚可,其余测量准确性差。
  • 81%完全性断裂和38%部分断裂患者存在寰枕关节非同心圆表现,主观软组织征象常见。

关键影像表现/征象

  • 81%(n=22)完全性断裂患者和38%(n=8)部分断裂患者存在寰枕关节非同心圆表现。
  • 100%完全性断裂患者有≥1项软组织征象,81%(n=22)有≥2项征象。
  • 73%(n=16)部分断裂患者有≥1项软组织征象。
  • 86%(n=18)部分断裂患者存在寰枕关节非同心圆表现和/或软组织征象。

诊断标准与关键数值

  • 完全性断裂损伤:C1-C2距离AUC=0.90(95%CI=0.83-0.97),寰枕距离AUC=0.95-0.98(95%CI=0.90-1.00),基底-齿突距离AUC=0.90(95%CI=0.82-0.98),准确性优。
  • 完全性断裂损伤:Powers比率AUC=0.85(95%CI=0.76-0.94)准确性良,基底-后轴连线AUC=0.74(95%CI=0.61-0.86)准确性尚可,寰齿间距AUC=0.69(95%CI=0.57-0.82)准确性差。
  • 部分断裂损伤:基底-齿突距离AUC=0.75(95%CI=0.62-0.88)准确性尚可。
  • 部分断裂损伤:Powers比率AUC=0.63(95%CI=0.47-0.79)、C1-C2距离AUC=0.60(95%CI=0.45-0.75)、寰齿间距AUC=0.55(95%CI=0.39-0.71)、寰枕距离AUC=0.63-0.65(95%CI=0.47-0.81)、基底-后轴连线AUC=0.60(95%CI=0.44-0.76)准确性均差。

临床应用与阅片要点

  • 在儿童颅颈交界区损伤评估中,完全性断裂损伤可参考C1-C2距离、寰枕距离和基底-齿突距离等测量指标。
  • 对疑似部分断裂损伤,测量指标准确性有限,需结合寰枕关节非同心圆表现及软组织征象等主观发现综合判断。
  • CT上主观颅颈损伤征象在儿童中常见,识别这些征象有助于提高损伤检出的敏感性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the accuracy of craniocervical measurements for identifying craniocervical injuries and the frequency of subjective findings of craniocervical injuries on CT in pediatric patients.

METHODS: Case-controlled retrospective review of patients ≤ 16 years old with craniocervical junction injuries. Receiver operator curves were created for common craniocervical measurements on CT comparing patients with complete and partial craniocervical injuries to uninjured cohort. Frequency of subjective CT findings of craniocervical injury was assessed in the injured cohort.

RESULTS: For complete disruption injuries (CD) (n = 27), C1-C2 distance (AUC = 0.90, 95%CI = 0.83-0.97), atlanto-occipital distance (AUC = 0.95-0.98, 95%CI = 0.90-1.00), and basion-dens distance (AUC = 0.90, 95%CI = 0.82-0.98) had excellent accuracy diagnosing injury. Powers ratio (AUC = 0.85, 95%CI = 0.76-0.94) had good, basion-posterior axial line (AUC = 0.74, 95%CI = 0.61-0.86) fair, and atlanto-dental distance (AUC = 0.69, 95%CI = 0.57-0.82) poor accuracy. For partial disruption injuries (PD) (n = 21), basion-dens distance (AUC = 0.75, 95%CI = 0.62-0.88) had fair accuracy diagnosing injury. Powers ratio (AUC = 0.63, 95%CI = 0.47-0.79), C1-C2 distance (AUC = 0.60, 95%CI = 0.45-0.75), atlanto-dental distance (AUC = 0.55, 95%CI = 0.39 = 0.71), atlanto-occipital distance (AUC = 0.63-0.65, 95%CI = 0.47-0.81), and basion-posterior axial line (AUC = 0.60, 95%CI = 0.44-0.76) all had poor accuracy. Eighty-one percent (n = 22) of CD and 38% (n = 8) of PD patients had non-concentric atlanto-occipital joints. One hundred percent of CD patients had ≥ 1 soft tissue finding and eighty-one percent (n = 22) had ≥ 2 findings. Seventy-three percent (n = 16) of PD patients had ≥ 1 soft tissue finding. Eighty-six percent (n = 18) of PD patients had non-concentric atlanto-occipital joints and/or soft tissue findings.

CONCLUSION: Craniocervical measurements have poor accuracy for identifying craniocervical injuries in pediatric patients with incomplete craniocervical ligament disruption. Subjective findings of craniocervical injury are frequently present on CT in pediatric patients and can help increase sensitivity for identifying injury.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Beckmann NM, Cheekatla SK, Chinapuvvula NR, et al. Accuracy of craniocervical measurements on CT for identifying partial or complete craniocervical ligament injuries in pediatric patients. Skeletal Radiol. 2020. PMID: 32691127. doi:10.1007/s00256-020-03555-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。