文献速递骨肌儿科影像MR

基于MRI容积定量测量不同年龄健康儿童正常髋关节积液量

Normal hip joint fluid volumes in healthy children of different ages, based on MRI volumetric quantitative measurement.
PubMed 文献 · Pediatr Radiol · 2020-06-29

本研究对70名8–17岁健康儿童行骨盆MRI(含大视野冠状位T2脂肪饱和序列),用半自动像素阈值法测量140个髋关节积液量,评估可行性与可靠性。平均积液量2.1 mL(范围0.38–5.41 mL),随年龄略增,男孩大于女孩(P=0.004);观察者内和观察者间一致性高(ICC分别为0.93和0.98)。

要点

  • 健康儿童髋关节平均积液量约2.1 mL(范围0.38–5.41 mL),男孩大于女孩(P=0.004)。
  • 该积液量在MRI单层上可表现为肉眼可见的较多液体,尤其在小儿,不应误判为关节积液。
  • 半自动像素阈值法测量髋关节积液可行且可靠,观察者内和观察者间ICC分别为0.93和0.98。

关键影像表现/征象

  • 髋关节积液平均容积为2.1 mL(范围0.38–5.41 mL),随年龄略增。
  • 男孩髋关节积液量大于女孩(P=0.004)。
  • 每髋平均处理时间2分41秒。

诊断标准与关键数值

  • 观察者内和观察者间一致性高,组内相关系数分别为0.93和0.98。
  • 观察者内平均容积差异为0.04 mL,观察者间平均容积差异为0.09 mL。

临床应用与阅片要点

  • 健康儿童髋关节平均积液量2.1 mL在单层MRI上可表现为肉眼可见的较多液体,尤其在小儿,不应误判为关节积液。
  • 半自动像素阈值法可用于儿童髋关节MRI积液定量测量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: While magnetic resonance imaging (MRI) of the pelvis and hips is common in pediatric patients, to date there are no data on the quantification of normal hip joint fluid volume in this patient population.

OBJECTIVE: We sought to assess the feasibility and reliability of quantitative hip joint fluid measurement in the pediatric population to estimate the normal volume of fluid in a pediatric hip joint.

MATERIALS AND METHODS: Seventy healthy children ages 8-17 years underwent a pelvic MRI including a large field of view coronal T2 fat-saturated sequence where hips were entirely imaged. Following 3 training sessions, 2 readers with experience in musculoskeletal imaging performed volumetric quantitative measurements of hip fluid (140 hips) using semiautomated pixel-based thresholding on custom MATLAB software.

RESULTS: The mean processing time per hip was 2 min, 41 s. The mean volume of fluid in a hip joint was 2.1 mL (range: 0.38-5.41 mL), increasing slightly with age. Volumes were also greater in boys than in girls (P=0.004). Intra-observer and interobserver agreement were high (intra-class correlation coefficients 0.93 and 0.98, respectively), with mean volume differences of 0.04 mL for intra-observer and 0.09 mL for interobserver.

CONCLUSION: A semiautomated pixel-based thresholding approach was feasible and reliable for measuring joint fluid in pediatric hip MRI. The average fluid volume of 2.1 mL can represent a visually substantial quantity of fluid per MRI slice, particularly in small children, and should not be misinterpreted as a joint effusion.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Quinn-Laurin V, Thejeel B, Chauvin NA, et al. Normal hip joint fluid volumes in healthy children of different ages, based on MRI volumetric quantitative measurement. Pediatr Radiol. 2020. PMID: 32601743. doi:10.1007/s00247-020-04744-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。