新型自适应迭代金属伪影减少法在全身低剂量CT骨骼普查中的临床评估
回顾性获取25例全身低剂量CT骨骼普查患者的投影数据,每例含两种金属植入物,比较原始图像与AiMAR强度2、4、5的重建图像。三位肌骨放射科医师独立评估,AiMAR 4在64.3%的序列中排名最高,局部评分优于原始和AiMAR 2,植入物周围噪声较原始图像降低56.3%。
要点
- AiMAR 4在64.3%的序列中获最高整体质量排名,局部金属伪影与解剖显示评分优于原始和AiMAR 2。
- AiMAR 4较原始图像在植入物周围降低噪声56.3%,AiMAR 5降低68.1%但40%植入物出现解剖模糊。
- AiMAR 4解剖显示与AiMAR 5相当,但金属伪影评分劣于AiMAR 5。
诊断标准与关键数值
- 三位阅读者基于诊断质量对全部序列进行整体排名,并对每个植入物的金属伪影和解剖显示进行局部评分。
- AiMAR 4在八种植入物中64.3%的序列排名最高。
- AiMAR 4局部金属伪影和解剖显示评分优于原始和AiMAR 2。
- AiMAR 4解剖显示与AiMAR 5相当,但金属伪影评分劣于AiMAR 5。
- AiMAR 4较原始图像植入物周围噪声降低56.3%,AiMAR 5降低68.1%但40%植入物出现解剖模糊。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate a new adaptive iterative metal artifact reduction algorithm (AiMAR) in whole-body low-dose CT (WBLDCT) skeletal survey examinations.
METHODS: Projection data were retrospectively obtained from 25 clinical WBLDCT skeletal survey patients, each with two types of metal implants. Images were reconstructed with bone and soft tissue kernels using four settings-original and AiMAR with strengths of 2, 4, and 5. All images were anonymized and randomized for a reader study, where three musculoskeletal radiologists independently determined the overall ranking of all series based on diagnostic quality, and local scoring of metal artifact and anatomy visualization for each implant. Quantitative image noise analysis was performed in areas close to the implants. Intraclass correlation coefficients (ICC) and Krippendorff's alpha were computed for inter-rater reliability.
RESULTS: AiMAR 4 was ranked the highest for 64.3% of the series across eight types of implants. For local scoring task, AiMAR 4 showed better metal artifact and anatomy visualization than the original and AiMAR 2. AiMAR 4 was comparable in anatomy visualization but inferior to AiMAR 5 in metal artifact scores. AiMAR 4 led to 56.3% noise reduction around the implant areas compared with the original images, and AiMAR 5 68.1% but also resulted in anatomy blurring in 40% of the implants. ICC and Krippendorff's alpha revealed at least substantial reliability in the local scores among the readers.
CONCLUSIONS: AiMAR was evaluated in WBLDCT skeletal surveys. AiMAR 4 demonstrated the highest overall quality ranking and improved local scores with noise reduction around implant areas.
引用
- Long Z, Tiegs-Heiden CA, Anderson TL, et al. Clinical evaluation of a new adaptive iterative metal artifact reduction method in whole-body low-dose CT skeletal survey examinations. Skeletal Radiol. 2020. PMID: 32691125. doi:10.1007/s00256-020-03547-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。