超声弹性成像评估肩袖肌腱及相关疾病的价值:系统综述与Meta分析
该系统综述与Meta分析纳入11项横断面研究,评估超声弹性成像在肩袖肌腱病变及相关疾病中的诊断价值。剪切波弹性成像显示粘连性肩关节囊炎肩的冈上肌腱与冈下肌腱倾向更硬,SMD分别为2.103与1.548,但均未达统计学显著;肩袖肌腱病或肌腱撕裂的肌腱弹性无显著差异。
要点
- 粘连性肩关节囊炎肩的冈上肌腱与冈下肌腱在剪切波弹性成像下倾向于更硬,但差异未达统计学显著。
- 肩袖肌腱病与肌腱撕裂的肌腱弹性与正常肩无显著差异。
- 剪切波速度与应变比值评估冈上肌腱弹性在肩袖肌腱病中均无显著差异。
核心结论
- Meta分析显示粘连性肩关节囊炎肩的冈上肌腱与冈下肌腱倾向于更硬。
- 肩袖肌腱病或肌腱撕裂的肌腱弹性与正常肩无显著差异。
研究设计与样本
- 系统综述与Meta分析,纳入11项横断面研究,检索PubMed与Embase。
- 主要结局为有与无指定病理状况的肩(或患者)之间肌腱弹性的标准化均数差(SMD)。
关键影像表现/征象
- 剪切波弹性成像评估粘连性肩关节囊炎肩的冈上肌腱SMD为2.103(95%CI -0.151至4.357,p=0.067),倾向更硬但未达统计学显著。
- 剪切波弹性成像评估粘连性肩关节囊炎肩的冈下肌腱SMD为1.548(95%CI -0.032至3.127,p=0.055),倾向更硬但未达统计学显著。
- 剪切波速度评估肩袖肌腱病冈上肌腱弹性SMD为-0.107(95%CI -0.524至0.310,p=0.615),无显著差异。
- 应变比值评估肩袖肌腱病冈上肌腱弹性SMD为0.153(95%CI -2.134至2.440,p=0.896),无显著差异。
- 仅1项研究用剪切波弹性成像研究肩袖肌腱撕裂,发现病变肩与正常肩肌腱弹性相似。
诊断标准与关键数值
- 粘连性肩关节囊炎冈上肌腱剪切波弹性成像SMD 2.103(95%CI -0.151至4.357,p=0.067)。
- 粘连性肩关节囊炎冈下肌腱剪切波弹性成像SMD 1.548(95%CI -0.032至3.127,p=0.055)。
- 肩袖肌腱病冈上肌腱剪切波速度SMD -0.107(95%CI -0.524至0.310,p=0.615)。
- 肩袖肌腱病冈上肌腱应变比值SMD 0.153(95%CI -2.134至2.440,p=0.896)。
临床应用与阅片要点
- 剪切波弹性成像显示粘连性肩关节囊炎肩的冈上肌腱与冈下肌腱倾向于更硬,但差异未达统计学显著。
- 肩袖肌腱病或肌腱撕裂的肌腱弹性与正常肩无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Sonoelastography has been increasingly used to investigate musculoskeletal disorders. The aim of this meta-analysis was to investigate the utility of sonoelastography in diagnosing rotator cuff tendon pathology and pertinent disorders.
METHODS: Searching through PubMed and Embase, we systemically reviewed clinical studies in which sonoelastography has been used for imaging rotator cuff tendon pathology and relevant disorders. The primary outcome was the standardized mean difference (SMD) of tendon elasticity between shoulders (or patients) with and without the designated pathological conditions.
RESULTS: A total of 11 cross-sectional studies were included in the meta-analysis. The supraspinatus and infraspinatus tendons assessed by shear wave sonoelastography were likely to be stiffer in shoulders with adhesive capsulitis, with a SMD of 2.103 (95% confidence interval (CI), - 0.151 to 4.357, p = 0.067) and a SMD of 1.548 (95% CI, - 0.032 to 3.127, p = 0.055), respectively. Regarding rotator cuff tendinopathy, there was no significant difference in the elasticity of supraspinatus tendons evaluated by shear wave velocity (SMD = - 0.107; 95% CI, - 0.524 to 0.310, p = 0.615) or strain ratios (SMD = 0.153, 95% CI, - 2.134 to 2.440, p = 0.896). Only one study used shear wave sonoelastography to investigate patients with rotator cuff tendon tears and found tendon that elasticity was similar between diseased and normal shoulders.
CONCLUSION: This meta-analysis revealed that supraspinatus and infraspinatus tendons tended to be stiffer in shoulders with adhesive capsulitis. Furthermore, no significant difference in tendon elasticity could be identified between shoulders with and without rotator cuff tendinopathy or tendon tears.
KEY POINTS: • Supraspinatus and infraspinatus tendons are likely to have decreased elasticity in shoulders with adhesive capsulitis, as assessed by shear wave sonoelastography. • There was no significant difference in tendon elasticity between shoulders with and without rotator cuff tendinopathy or tendon tears when evaluated by strain and shear wave sonoelastography.
引用
- Chiu YH, Chang KV, Chen IJ, et al. Utility of sonoelastography for the evaluation of rotator cuff tendon and pertinent disorders: a systematic review and meta-analysis. Eur Radiol. 2020. PMID: 32666319. doi:10.1007/s00330-020-07059-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。