双能CT定量肩袖肌肉脂肪的初步研究
本研究评估双能CT(DECT)定量肩袖脂肪退变的能力。对10例患者12侧肩关节行双源CT检查,经物质分解计算DECT脂肪分数,并与视觉Goutallier评分对照。DECT脂肪分数与Goutallier评分呈高度秩相关(ρ=0.92,p<0.0001)。
要点
- DECT脂肪分数与Goutallier评分高度相关(ρ=0.92,p<0.0001)。
- 大圆肌和皮下脂肪可作0%和100%脂肪内参照。
- 基于CT值的脂肪分数与Goutallier评分也呈高度线性相关。
核心结论
- 物质分解后DECT直接脂肪分数是定量评估脂肪退变的新方法,与临床公认标准高度相关。
研究设计与样本
- 初步研究,纳入10例患者12侧肩关节,使用双源CT系统采集临床指征肩关节CT。
关键影像表现/征象
- 大圆肌平均脂肪分数为2.9%±4.0%,皮下脂肪为99.5%±2.6%,可作0%和100%脂肪内参照。
- DECT脂肪分数与Goutallier评分高度秩相关:ρ=0.92,p<0.0001。
- DECT 70 keV虚拟单能图像CT值脂肪分数与Goutallier评分高度线性相关:ρ=0.83,p<0.0001。
- 单能CT 100 kV图像CT值脂肪分数与Goutallier评分高度线性相关:ρ=0.82,p<0.0001。
诊断标准与关键数值
- 以视觉Goutallier评分为参考标准。
- DECT脂肪分数与Goutallier评分秩相关系数ρ=0.92(p<0.0001)。
- DECT 70 keV CT值脂肪分数与Goutallier评分线性相关系数ρ=0.83(p<0.0001)。
- SECT 100 kV CT值脂肪分数与Goutallier评分线性相关系数ρ=0.82(p<0.0001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the ability of dual-energy CT (DECT) as a novel technique to quantify the degree of rotator cuff fat degeneration.
METHOD: Clinically indicated shoulder CT exams for evaluation of osteoarthritis, rotator cuff arthropathy, pain or instability, or preoperative planning were acquired using dual-source CT systems. Rotator cuff DECT fat fraction after material decomposition was calculated off the sagittal image. Fat fractions were also assessed using CT numbers from dual energy virtual monochromatic images (70 keV) and single-energy CT (SECT) images (100 kV). Visual subjective Goutallier scores of the rotator cuff muscles were used as the reference standard.
RESULTS: 12 shoulders from 10 patients were analyzed, with bilateral shoulders evaluated in two patients (mean age 69 years (range 19-97)). Three patients were male and seven were female, with mean BMI of 32 (range 26-41). Mean fat fraction of the teres major and subcutaneous fat were, 2.9 % ± 4.0 % and 99.5 % ± 2.6 %, respectively, rendering these as reliable internal standards for 0% and 100 % fat. Mean DECT fat fractions of the rotator cuff were compared to Goutallier scores, revealing a high strength of rank correlation: ρ = 0.92, p < 0.0001. Mean fat fraction assessed with CT numbers also revealed high strengths of linear associations: ρ = 0.83, p < 0.0001 and ρ = 0.82, p < 0.0001, for DECT 70 keV and SECT 100 kV, respectively.
CONCLUSIONS: DECT direct fat fraction after material decomposition presents a novel approach to quantitative assessment of fatty degeneration, which has excellent correlation with clinically accepted standards.
引用
- Baillargeon AM, Baffour FI, Yu L, et al. Fat quantification of the rotator cuff musculature using dual-energy CT-A pilot study. Eur J Radiol. 2020. PMID: 32634758. doi:10.1016/j.ejrad.2020.109145
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。