人腰椎与基于CT的模型之间的几何与体积关系
本研究对6具人腰椎标本行CT扫描、骨标本3D扫描并构建CT网格模型与3D打印模型,比较各模型的人工测量值及分割指标。除椎体宽度外各参数人工测量无统计学差异,3D扫描模型与CT模型平均Hausdorff距离0.99 mm、Dice系数0.90,CT模型体积大于骨标本模型。
要点
- CT模型与3D扫描骨模型相比,平均Hausdorff距离0.99 mm(SD 0.55 mm),Dice系数0.90(SD 0.07)。
- 3D扫描模型平均体积41.6 ml,CT模型平均体积45.9 ml,CT模型较骨标本模型大4.3 ml(p < 0.001)。
- 除椎体宽度外(p = 0.044),各模型类型间各参数人工测量无统计学差异;全部测量均值比较无统计学差异(p = 0.247)。
核心结论
- 本研究阐明了人腰椎与基于CT的椎体模型之间的几何与体积关系。
- 分割指标显示以3D扫描骨为参照时,骨与CT测量之间存在约1 mm差异,并由较大的CT模型与较小的骨之间4.3 ml的体积差所印证。
研究设计与样本
- 研究论文,取6具人腰椎标本行CT扫描,骨标本清洗后行3D扫描,再由CT数据构建3D网格模型并3D打印。
- 分析四类模型:解剖骨、3D扫描模型、CT模型和3D打印模型;对所有模型类型行人工测量,并将3D扫描模型与CT模型行分割指标比较。
诊断标准与关键数值
- 3D扫描模型与CT模型比较:平均Hausdorff距离0.99 mm(SD 0.55 mm),平均Dice系数0.90(SD 0.07)。
- 3D扫描模型平均体积41.6 ml,CT模型平均体积45.9 ml(p < 0.001)。
- 各模型类型间除椎体宽度外(p = 0.044),其余各参数人工测量均无统计学差异;全部测量均值比较无统计学差异(p = 0.247)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Crucial to the process of three-dimensional (3D) printing is the knowledge of how the actual structure or organ relates dimensionally to its corresponding medical image. This study will examine the differences between human lumbar vertebrae, 3D scans of these bones, 3D models based on computed tomographic (CT) scans, and 3D-printed models.
MATERIALS AND METHODS: CT scans were obtained for six human lumbar spines. The bones were cleaned, and 3D scanned. 3D mesh models were created from the CT data, and then 3D printed. Four models were analyzed: anatomic bones, 3D-scanned models, CT-models, and 3D-printed models. Manual measurements were performed for all model types, and segmentation metric comparisons were performed comparing the 3D-scanned models to the CT-models.
RESULTS: There was no statistical difference between manual measurements when comparing each parameter of all model types, except for vertebral width (p = 0.044). There was no statistical difference when comparing the average of all measurements between all model types (p = 0.247). The mean Hausdorff distance was 0.99 mm (SD 0.55 mm) when comparing 3D-scanned model to CT-model. The mean Dice coefficient was 0.90 (SD 0.07) when comparing 3D-scanned model to CT-model. The mean volume for 3D-scanned model and CT-model were 41.6 ml and 45.9 ml (p < 0.001), respectively.
CONCLUSION: This study clarifies the geometric and volumetric relationship between human lumbar vertebra and CT-based vertebral models. Segmentation metrics reveal a 1 mm difference between examined bones (using the 3D-scanned bone as a surrogate), and the CT measurements. This is confirmed by a volumetric difference of 4.3 ml, between the larger CT-based model and the smaller bone.
引用
- Kanawati A, Fernandes RJR, Gee A, et al. Geometric and Volumetric Relationship Between Human Lumbar Vertebra and CT-based Models. Acad Radiol. 2020. PMID: 32620526. doi:10.1016/j.acra.2020.05.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。