文献速递乳腺乳腺X线

自动化结局反馈应用于乳腺断层合成筛查的采纳情况及对性能的影响

The Adoption and Impact on Performance of an Automated Outcomes Feedback Application for Tomosynthesis Screening Mammography.
PubMed 文献 · J Am Coll Radiol · 2020-07-21

这项前瞻性干预研究评估了自动化结局反馈应用在乳腺断层合成筛查中的采纳率及其对放射科医生判读性能的影响。18名放射科医生审阅了68.5%的可用反馈病例,其中17.4%被认为可能影响未来决策。在8名学术放射科医生亚组中,干预后异常判读率从7.5%降至6.7%,活检阳性预测值从40.6%升至51.3%,特异度从93.0%升至93.9%,而癌症检出率和敏感度无显著差异。

要点

  • 18名放射科医生审阅了68.5%的反馈病例,其中17.4%被认为可能影响未来决策。
  • 8名学术放射科医生亚组干预后异常判读率从7.5%降至6.7%(aOR 0.86,P<0.01)。
  • 活检阳性预测值从40.6%升至51.3%(aOR 1.48,P=0.011),特异度从93.0%升至93.9%(aOR 1.17,P<0.01)。

诊断标准与关键数值

  • 8名学术放射科医生亚组干预前后比较:异常判读率从7.5%降至6.7%(aOR 0.86,P<0.01)。
  • 活检阳性预测值从40.6%升至51.3%(aOR 1.48,P=0.011)。
  • 特异度从93.0%升至93.9%(aOR 1.17,P<0.01)。
  • 每1000次检查癌症检出率从5.8升至6.1(aOR 1.01,P=0.91),敏感度从81.2%降至78.7%(aOR 0.84,P=0.47),均无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate a tomosynthesis screening mammography automated outcomes feedback application's adoption and impact on performance.

METHODS: This prospective intervention study evaluated a feedback application that provided mammographers subsequent imaging and pathology results for patients that radiologists had personally recalled from screening. Deployed to 13 academic and 5 private practice attending radiologists, adoption was studied from March 29, 2018, to March 20, 2019. Radiologists indicated if reviewed feedback would influence future clinical decisions. For a subset of eight academic radiologists consistently interpreting screening mammograms during the study, performance metrics were compared pre-intervention (January 1, 2016, to September 30, 2017) and post-intervention (October 1, 2017 to June 30, 2018). Abnormal interpretation rate, positive predictive value of biopsies performed, sensitivity, specificity, and cancer detection rate were compared using Pearson's χ2 test. Logistic regression models were fit, adjusting for age, race, breast density, prior comparison, breast cancer history, and radiologist.

RESULTS: The 18 radiologists reviewed 68.5% (1,398 of 2,042) of available feedback cases and indicated that 17.4% of cases (243 of 1,398) could influence future decisions. For the eight academic radiologist subset, after multivariable adjustment with comparison to pre-intervention, average abnormal interpretation rate decreased (from 7.5% to 6.7%, adjusted odds ratio [aOR] 0.86, P < .01), positive predictive value of biopsies performed increased (from 40.6% to 51.3%, aOR 1.48, P = .011), and specificity increased (from 93.0% to 93.9%, aOR 1.17, P < .01) post-intervention. There was no difference in cancer detection rate per 1,000 examinations (from 5.8 to 6.1, aOR 1.01, P = .91) or sensitivity (from 81.2% to 78.7%, aOR 0.84, P = .47).

CONCLUSIONS: Radiologists used a screening mammography automated outcomes feedback application. Its use decreased false-positive examinations, without evidence of reduced cancer detection.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Sippo DA, Sullivan AM, Cohen A, et al. The Adoption and Impact on Performance of an Automated Outcomes Feedback Application for Tomosynthesis Screening Mammography. J Am Coll Radiol. 2020. PMID: 32707191. doi:10.1016/j.jacr.2020.05.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。