文献速递乳腺乳腺X线

对比增强能谱乳腺摄影影像组学列线图预测乳腺癌腋窝淋巴结转移:多中心研究

Radiomics nomogram of contrast-enhanced spectral mammography for prediction of axillary lymph node metastasis in breast cancer: a multicenter study.
PubMed 文献 · Eur Radiol · 2020-06-30

本回顾性多中心研究纳入两家医院394例接受对比增强能谱乳腺摄影(CESM)检查的乳腺癌患者,构建包含影像组学标签与CESM报告的淋巴结状态的列线图,用于术前预测腋窝淋巴结转移。列线图在训练集、内部验证集和外部验证集的AUC分别为0.774(95%CI 0.689-0.858)、0.767(95%CI 0.583-0.857)和0.79(95%CI 0.63-0.94);列线图 cutoff 评分为-1.49(对应总分49分)时诊断腋窝淋巴结转移的敏感度>95%。结论认为该基于CESM的影像组学列线图是无创预测工具,在术前预测腋窝淋巴结转移方面显示出良好应用前景。

要点

  • 基于CESM的影像组学列线图在训练集、内部验证集和外部验证集的AUC分别为0.774、0.767和0.79。
  • 列线图cutoff评分为-1.49(对应总分49分)时,诊断腋窝淋巴结转移的敏感度>95%。
  • 列线图包含影像组学标签和CESM报告的淋巴结状态,可用于术前无创预测腋窝淋巴结转移。

核心结论

  • 基于CESM的影像组学列线图是无创预测工具,在乳腺癌腋窝淋巴结转移的术前预测中显示出良好应用前景。

研究设计与样本

  • 回顾性研究,纳入两家医院394例接受CESM检查的乳腺癌患者。
  • 采用LASSO logistic回归进行特征选择并构建影像组学标签,列线图模型包含影像组学标签和独立临床因素。
  • 使用ROC曲线在训练集、内部验证集和外部验证集中确认列线图性能。

诊断标准与关键数值

  • 列线图模型(包含影像组学标签和CESM报告的淋巴结状态)在训练集、内部验证集和外部验证集的AUC分别为0.774(95%CI 0.689-0.858)、0.767(95%CI 0.583-0.857)和0.79(95%CI 0.63-0.94)。
  • 影像组学列线图的cutoff评分为-1.49,对应总分49分,诊断腋窝淋巴结转移的敏感度>95%。

临床应用与阅片要点

  • 列线图包含影像组学标签和CESM报告的淋巴结状态,可用于术前预测乳腺癌腋窝淋巴结转移。
  • 列线图cutoff评分为-1.49(对应总分49分)时诊断腋窝淋巴结转移的敏感度>95%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aims to establish and validate a radiomics nomogram based on contrast-enhanced spectral mammography (CESM) for prediction of axillary lymph node (ALN) metastasis in breast cancer.

METHODS: This retrospective study included 394 patients with breast cancer who underwent CESM examination in two hospitals. The least absolute shrinkage and selection operator (LASSO) logistic regression was established for feature selection and utilized to construct radiomics signature. The nomogram model included the radiomics signature and independent clinical factors. The receiver operating characteristic (ROC) curves were used to confirm the performance of the nomogram in training and validation sets.

RESULTS: The nomogram model, which includes the radiomics signature and the CESM-reported lymph node status, has areas under the ROC curves of 0.774 (95% confidence interval (CI) 0.689-0.858), 0.767 (95% CI 0.583-0.857), and 0.79 (95% CI 0.63-0.94) in the training, internal validation, and external validation sets, respectively. We identified the cutoff score in the radiomics nomogram as - 1.49, which corresponded to a total point of 49 that could diagnose ALN metastasis with a sensitivity of > 95%.

CONCLUSIONS: The CESM-based radiomics nomogram is a noninvasive predictive tool that shows good application prospects in the preoperative prediction of ALN metastasis in breast cancer.

KEY POINTS: • The CESM-based radiomics nomogram shows good performance in predicting ALN metastasis in breast cancer. • The application of radiomics nomogram in this study provides a new approach for establishing a prediction model with multiple characteristics. • The nomogram has good application prospects in assisting clinical decision makers.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Mao N, Yin P, Li Q, et al. Radiomics nomogram of contrast-enhanced spectral mammography for prediction of axillary lymph node metastasis in breast cancer: a multicenter study. Eur Radiol. 2020. PMID: 32607630. doi:10.1007/s00330-020-07016-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。