文献速递乳腺乳腺X线

基于人群的100万次数字乳腺X线筛查队列中放射科医师阅读性能的范围

Range of Radiologist Performance in a Population-based Screening Cohort of 1 Million Digital Mammography Examinations.
PubMed 文献 · Radiology · 2020-07-28

该回顾性研究纳入瑞典斯德哥尔摩县2008至2015年40-74岁女性全部全视野数字乳腺X线筛查影像,共1 186 045次检查、110名阅片医师,其中24名为高年资阅片医师。总体首读者敏感度为73%(95%CI:69%,77%),特异度为96%(95%CI:95%,97%);高年资阅片医师各四分位组敏感度均值范围为63%至84%,特异度范围为95%至98%。基底型癌的敏感度差异极大,敏感度最低和最高的高年资阅片医师分别检出53%和89%的癌症(P < .001)。

要点

  • 高年资阅片医师间敏感度差异大,四分位组均值范围63%至84%。
  • 基底型癌敏感度差异最大,最低与最高组分别为53%和89%。
  • 总体首读者敏感度73%(95%CI:69%,77%),特异度96%(95%CI:95%,97%)。

核心结论

  • 高年资阅片医师之间存在广泛的性能差异,敏感度因肿瘤特征而异,这些基准可用于评估新兴人工智能计算机辅助检测系统的性能。

研究设计与样本

  • 回顾性研究,纳入2008至2015年瑞典斯德哥尔摩县40-74岁女性全视野数字乳腺X线筛查影像,共418 041名女性(平均年龄54岁±10),1 186 045次数字乳腺X线检查,110名阅片医师,其中24名为高年资阅片医师(年阅片量超过5000次筛查乳腺X线检查),972 899次检查由高年资阅片医师评估;真阳性定义为12个月内病理证实的癌症。

诊断标准与关键数值

  • 总体首读者敏感度73%(95%CI:69%,77%),总体特异度96%(95%CI:95%,97%);高年资阅片医师各四分位组敏感度均值范围为63%至84%,特异度均值范围为95%至98%;基底型癌敏感度最低和最高的高年资阅片医师分别为53%和89%(P < .001)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background There is great interest in developing artificial intelligence (AI)-based computer-aided detection (CAD) systems for use in screening mammography. Comparative performance benchmarks from true screening cohorts are needed. Purpose To determine the range of human first-reader performance measures within a population-based screening cohort of 1 million screening mammograms to gauge the performance of emerging AI CAD systems. Materials and Methods This retrospective study consisted of all screening mammograms in women aged 40-74 years in Stockholm County, Sweden, who underwent screening with full-field digital mammography between 2008 and 2015. There were 110 interpreting radiologists, of whom 24 were defined as high-volume readers (ie, those who interpreted more than 5000 annual screening mammograms). A true-positive finding was defined as the presence of a pathology-confirmed cancer within 12 months. Performance benchmarks included sensitivity and specificity, examined per quartile of radiologists' performance. First-reader sensitivity was determined for each tumor subgroup, overall and by quartile of high-volume reader sensitivity. Screening outcomes were examined based on the first reader's sensitivity quartile with 10 000 screening mammograms per quartile. Linear regression models were fitted to test for a linear trend across quartiles of performance. Results A total of 418 041 women (mean age, 54 years ± 10 [standard deviation]) were included, and 1 186 045 digital mammograms were evaluated, with 972 899 assessed by high-volume readers. Overall sensitivity was 73% (95% confidence interval [CI]: 69%, 77%), and overall specificity was 96% (95% CI: 95%, 97%). The mean values per quartile of high-volume reader performance ranged from 63% to 84% for sensitivity and from 95% to 98% for specificity. The sensitivity difference was very large for basal cancers, with the least sensitive and most sensitive high-volume readers detecting 53% and 89% of cancers, respectively (P < .001). Conclusion Benchmarks showed a wide range of performance differences between high-volume readers. Sensitivity varied by tumor characteristics. © RSNA, 2020 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Salim M, Dembrower K, Eklund M, et al. Range of Radiologist Performance in a Population-based Screening Cohort of 1 Million Digital Mammography Examinations. Radiology. 2020. PMID: 32720866. doi:10.1148/radiol.2020192212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。