文献速递乳腺US

诊断乳腺影像报告和数据系统3至5类乳腺病变的改良模型:回顾性分析与列线图开发

Modified Model for Diagnosing Breast Imaging Reporting and Data System Category 3 to 5 Breast Lesions: Retrospective Analysis and Nomogram Development.
PubMed 文献 · J Ultrasound Med · 2020-07-18

本研究回顾性纳入2016年10月至2019年8月经B型超声和超声造影检查并经组织病理学诊断的206个乳腺病变(136个良性、70个恶性),通过lasso回归筛选超声特征建立改良模型并开发两个列线图,经bootstrap重采样内部验证。改良模型与超声联合超声造影模型的敏感度分别为93.3%和94.3%、特异度分别为81.4%和85.9%、准确率分别为88.7%和89.3%、曲线下面积分别为0.944和0.957,两模型诊断效能无统计学显著差异(P = .097)。结论认为指标更少的改良模型可简便有效地诊断BI-RADS 3至5类乳腺病变的恶性,且不降低诊断效能。

要点

  • 改良模型纳入形态、边缘、微钙化、增强强度、增强范围、增强时间6项超声特征。
  • 改良模型诊断BI-RADS 3至5类乳腺病变的AUC为0.944,敏感度93.3%、特异度81.4%。
  • 与超声联合超声造影模型相比,改良模型诊断效能无统计学显著差异(P = .097)。

核心结论

  • 指标更少的改良模型可简便有效地诊断BI-RADS 3至5类乳腺病变的恶性,且不降低诊断效能。

研究设计与样本

  • 回顾性分析2016年10月至2019年8月经B型超声和超声造影检查并经组织病理学诊断的乳腺病变。
  • 共纳入198例患者的206个乳腺病变,其中良性136个、恶性70个。
  • 采用lasso回归分析从超声联合超声造影模型中筛选诊断价值较高的超声特征建立改良模型,并开发两个列线图。
  • 结果通过bootstrap重采样进行内部验证。

关键影像表现/征象

  • 改良模型纳入的超声特征为形态、边缘、微钙化、增强强度、增强范围和增强时间。

诊断标准与关键数值

  • 超声联合超声造影模型诊断BI-RADS 3至5类乳腺病变的敏感度为94.3%、特异度为85.9%、准确率为89.3%、AUC为0.957。
  • 改良模型诊断BI-RADS 3至5类乳腺病变的敏感度为93.3%、特异度为81.4%、准确率为88.7%、AUC为0.944。
  • 两模型诊断效能无统计学显著差异(P = .097)。
  • bootstrap校正后超声联合超声造影模型与改良模型的AUC分别为0.955和0.940。
  • bootstrap校正后两模型的敏感度、特异度和准确率与上述结果一致。

临床应用与阅片要点

  • 原文结论认为改良模型可简便有效地诊断BI-RADS 3至5类乳腺病变的恶性,且不降低诊断效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to explore a modified model to simplify the diagnostic process for American College of Radiology Breast Imaging Reporting and Data System category 3 to 5 breast lesions and evaluate the model's diagnostic efficacy.

METHODS: A retrospective review was conducted of breast lesions examined by B-mode ultrasound (US) and contrast-enhanced ultrasound (CEUS) and diagnosed by histopathologic examination from October 2016 to August 2019. The US characteristics of a combined model (US + CEUS model) with relatively high diagnostic value were selected by a lasso regression analysis to establish a modified model. Two nomograms were developed. The results were internally validated by bootstrap resampling.

RESULTS: Overall, 206 breast lesions in 198 patients, 136 benign and 70 malignant, were included. Ultrasound characteristics included in the modified model were shape, margin, microcalcification, enhanced intensity, enhanced scope, and enhanced time. For the US + CEUS model and modified model, sensitivities were 94.3% and 93.3%; specificities were 85.9% and 81.4%; accuracies were 89.3% and 88.7% and areas under the curve were 0.957 and 0.944, respectively. No statistically significant differences were seen in the diagnostic efficacies of the models (P = .097). Bootstrap-corrected sensitivities, specificities. and accuracies of the models were consistent with these results. Bootstrap-corrected areas under the curve for the US + CEUS model and the modified model were 0.955 and 0.940, respectively.

CONCLUSIONS: The modified model with fewer indicators conveniently and effectively diagnosed the malignancy of Breast Imaging Reporting and Data System category 3 to 5 breast lesions without reducing diagnostic efficacy.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Zhou P, Jin C, Lu J, et al. Modified Model for Diagnosing Breast Imaging Reporting and Data System Category 3 to 5 Breast Lesions: Retrospective Analysis and Nomogram Development. J Ultrasound Med. 2020. PMID: 32681744. doi:10.1002/jum.15385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。