文献速递乳腺US

冠状面单独评估在自动乳腺超声检查女性中的价值

The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound.
PubMed 文献 · Radiol Med · 2020-07-16

研究纳入188例致密型乳腺女性共67个乳腺病灶(25个恶性,42个良性),由3名乳腺影像放射科医生分别仅评估冠状面重建图像与完整多平面视图。冠状面视图阅读时间显著更低,但敏感度较低(各读者均未达统计学显著),特异度较高;结论认为完整多平面评估仍属必要。

要点

  • 冠状面单独阅片阅读时间显著低于完整多平面视图(三位读者均p<0.035)。
  • 冠状面单独阅片敏感度低于多平面视图,三位读者差异均未达统计学显著。
  • 冠状面单独阅片特异度高于多平面视图,仅15年经验读者差异达统计学显著(p=0.002)。

核心结论

  • 冠状面视图可显著缩短阅读时间,在筛查场景中是有价值的特征,但其诊断性能使完整多平面评估成为必需。

研究设计与样本

  • 研究于2017年8月至10月连续纳入因乳腺X线摄影后超声评估、术前评估或已知良性病灶随访而转诊至本机构的致密型乳腺女性,均接受额外自动乳腺超声检查。
  • 共纳入188例女性,67个乳腺病灶,其中25个(37%)恶性、42个(63%)良性。
  • 3名乳腺影像放射科医生(乳腺影像经验分别为5年、15年、25年)对每例检查阅片两次:先仅评估重建冠状面图像,再评估完整多平面视图。

诊断标准与关键数值

  • 与完整多平面视图相比,冠状面视图三位读者阅读时间分别为83±37、84±43、76±30秒 vs 163±109、131±57、151±42秒(p<0.035)。
  • 与完整多平面视图相比,冠状面视图三位读者敏感度分别为44.8%、62.1%、55.2% vs 69.0%(p=0.059)、65.5%(p=0.063)、72.4%(p=0.076)。
  • 与完整多平面视图相比,冠状面视图三位读者特异度分别为94.1%、93.7%、94.2% vs 89.5%(p=0.093)、87.4%(p=0.002)、91.6%(p=0.383)。
  • 经验最丰富与最不丰富读者之间的一致性:分类变量为一般至中等,连续变量为显著。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Aim of the study was to evaluate the value of automated breast ultrasound (AUS) in women with dense breast, in terms of reading times, diagnostic performance and interobserver agreement. The assessment of coronal images alone versus the complete multiplanar (MPR) views was evaluated.

METHODS: Between August and October 2017, consecutive patients with dense breast that were referred to our Institute, for post-mammography ultrasound assessment, pre-operative assessment or follow-up of known benign lesions, were invited to undergo an additional study with AUS. Three radiologists, (5, 15 and 25 years of experience in breast imaging), reviewed the exams twice: first assessing reconstructed coronal images alone, second the complete MPR views. Reading times, diagnostic performance and interobserver agreement were assessed.

RESULTS: One hundred eighty-eight women were included, for a total of 67 breast lesions, 25 (37%) malignant and 42 (63%) benign. Compared to MPR, coronal view was associated with: lower reading times, respectively, for the three readers: 83 ± 37, 84 ± 43 and 76 ± 30 versus 163 ± 109, 131 ± 57, 151 ± 42 s (p < 0.035); lower sensitivity: 44.8%, 62.1%, 55.2% versus 69.0% (p = 0.059), 65.5% (p = 0.063), 72.4% (p = 0.076), respectively; better specificity: 94.1%, 93.7%, 94.2% versus 89.5% (p = 0.093), 87.4% (p = 0.002), 91.6% (p = 0.383), respectively. Agreement between the most and the least experienced reader was fair to moderate for categorical variables and significant for continuous ones.

CONCLUSION: The coronal view allows significantly lower reading times, a valuable feature in the screening setting, but its diagnostic performance makes the complete multiplanar assessment mandatory.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Schiaffino S, Gristina L, Tosto S, et al. The value of coronal view as a stand-alone assessment in women undergoing automated breast ultrasound. Radiol Med. 2020. PMID: 32676876. doi:10.1007/s11547-020-01250-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。