基于高斯混合模型聚类分析的表观扩散系数值:评估子宫内膜样癌分级的新方法
本研究对122例子宫内膜样癌患者的ADC图进行高斯混合模型聚类分析,在训练队列(n=63)中定义三个聚类ADC范围,并在训练和验证队列(n=59)中计算每个患者的聚类比例,发现低ADC的聚类1比例与组织学分级呈显著正相关,验证队列结果一致。
要点
- 聚类1(低ADC值范围490-699×10⁻⁶ mm²/s)比例与子宫内膜样癌组织学分级呈正相关。
- 训练队列中聚类1比例与分级相关系数ρ=0.34(p=0.0059),验证队列ρ=0.44(p=0.0006)。
- 训练队列中高级别(3级)病变的聚类1比例显著高于低级别(1-2级)病变(p=0.0084)。
核心结论
- 包含低ADC体素的聚类1比例与子宫内膜样癌的组织学分级显著正相关。
- 基于高斯混合模型对体素ADC数据的聚类分析对子宫内膜样癌分级有效。
研究设计与样本
- 回顾性研究,纳入122例患者(训练队列n=63,验证队列n=59),成像时间为2015年5月至2020年2月。
- 在训练队列中对ADC图进行手动分割获取每个患者的ADC数据,汇总得到「All-patient」ADC数据。
- 对All-patient ADC数据进行三聚类分析,定义聚类1 ADC范围为490-699×10⁻⁶ mm²/s,聚类2为700-932×10⁻⁶ mm²/s,聚类3为超过933×10⁻⁶ mm²/s。
- 在训练和验证队列中,根据上述ADC范围将每个患者的ADC数据分类到三个聚类,计算聚类比例并与组织学分级比较。
诊断标准与关键数值
- 训练队列中聚类1比例与组织学分级呈显著正相关(ρ=0.34,p=0.0059)。
- 训练队列中高级别(3级)病变的聚类1比例显著高于低级别(1和2级)病变(p=0.0084)。
- 验证队列中聚类1比例与组织学分级呈显著正相关(ρ=0.44,p=0.0006)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The purpose of our study was to perform Gaussian mixture model (GMM)-based cluster analysis of the apparent diffusion coefficient (ADC) data of patients with endometrioid carcinoma, and to evaluate the relationship between histological grade and the ratios of the different clusters in each patient.
METHODS: This retrospective study enrolled 122 patients (training: n = 63; and validation: n = 59) imaged between May 2015 and February 2020. In the training cohort, manual segmentation was performed on the ADC maps to obtain the ADC data of each patient, and these ADC data were summated to obtain the "All-patient" ADC data. Cluster analysis (three clusters) was performed on this All-patient ADC data, and the ADC ranges of each cluster were defined as follows: cluster 1, 490-699 × 10-6 mm2/s; cluster 2, 700-932 × 10-6 mm2/s; and cluster 3, over 933 × 10-6 mm2/s. In the training and validation cohorts, the ADC data of each patient was classified into three clusters according to these ADC ranges. The cluster ratios of each patient were calculated and compared with histological grade.
RESULTS: In the training cohort, a significant positive correlation was found between the cluster 1 ratio and histological grade (ρ = 0.34, p = 0.0059). The cluster 1 ratios of high-grade lesions (grade 3) were significantly higher than those of low-grade lesions (grades 1 and 2) (p = 0.0084). A similar significant positive correlation was found between the cluster 1 ratio and histological grade in the validation cohort (ρ = 0.44, p = 0.0006).
CONCLUSIONS: The cluster 1 ratio containing voxels with low ADC was significantly correlated with the histological grade of endometrioid carcinoma.
KEY POINTS: • We performed Gaussian mixture model (GMM)-based cluster analysis of the apparent diffusion coefficient (ADC) data of patients with endometrioid carcinoma. • The cluster 1 ratio, which included low ADC values, was significantly positive correlated with histological grade in the training and validation cohorts. • The GMM-based cluster analysis of voxel-based ADC data was effective for grading endometrioid carcinoma.
引用
- Kageyama S, Mori N, Mugikura S, et al. Gaussian mixture model-based cluster analysis of apparent diffusion coefficient values: a novel approach to evaluate uterine endometrioid carcinoma grade. Eur Radiol. 2020. PMID: 32725334. doi:10.1007/s00330-020-07047-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。