文献速递泌尿生殖妇产影像MR

体素内不相干运动扩散加权成像鉴别腺癌起源于子宫体或子宫颈的可行性

Feasibility of intravoxel incoherent motion diffusion-weighted imaging in distinguishing adenocarcinoma originated from uterine corpus or cervix.
PubMed 文献 · Abdom Radiol (NY) · 2021-01-01

前瞻性纳入80例经组织病理学证实的宫颈或子宫内膜腺癌,治疗前行3.0T MR的IVIM DWI采集,分析5项形态学特征及IVIM衍生参数。肿瘤位置鉴别子宫内膜腺癌与宫颈腺癌的AUC最高为0.891,f值最佳截断值0.261时AUC为0.837;由肿瘤位置、ADC和f组成的联合诊断模型AUC最大为0.967,敏感度88.14%、特异度100.00%、准确率91.25%。

要点

  • 肿瘤位置是鉴别子宫内膜腺癌与宫颈腺癌最有价值的单一形态学特征,AUC为0.891。
  • IVIM DWI衍生参数中f值诊断效能最佳,最佳截断值0.261,AUC为0.837。
  • 肿瘤位置、ADC和f组成的联合诊断模型AUC达0.967,敏感度88.14%、特异度100.00%、准确率91.25%。

关键影像表现/征象

  • 分析5项形态学特征,其中肿瘤位置鉴别子宫内膜腺癌与宫颈腺癌的AUC最高,为0.891。

诊断标准与关键数值

  • f值鉴别子宫内膜腺癌与宫颈腺癌的最佳截断值为0.261,AUC为0.837。
  • 肿瘤位置、ADC和f组成的联合诊断模型AUC为0.967,敏感度88.14%、特异度100.00%、准确率91.25%。

临床应用与阅片要点

  • 作者认为IVIM DWI衍生参数可为传统形态学特征提供额外诊断价值。
  • 作者认为联合诊断模型是预测子宫腺癌起源的有前景的影像工具,进一步有助于治疗决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To prospectively assess the incremental value of intravoxel incoherent motion (IVIM) DWI in determining whether the adenocarcinoma originated from the uterine corpus or cervix.

METHODS: Eighty consecutive uterine adenocarcinomas from the cervix or endometrium confirmed by histopathology underwent IVIM DWI acquisition on a 3.0T MR scanner before treatment. Five morphologic features were analyzed using Fisher exact test; IVIM DWI-derived parameters, including apparent diffusion coefficient (ADC), true coefficient diffusivity (D), perfusion-related diffusivity (D*), and perfusion fraction (f) were compared using two-sample independent t-test or Mann-Whitney U test. Logistic regression analysis was used to develop different diagnosis model. The ROCs of these variables and diagnostic models were compared to evaluate the diagnostic efficiency.

RESULTS: Among single morphologic features, tumor location yielded the highest AUC of 0.891 in distinguishing endometrial adenocarcinoma (EAC) from cervical adenocarcinoma (CAC). Among single IVIM DWI-derived parameters, f values showed the best diagnostic performance (AUC: 0.837) at the optimal cut-off value of 0.261. Additionally, the combined diagnostic model, which consisted of tumor location, ADC and f showed the largest AUC of 0.967 with the highest sensitivity of 88.14%, highest specificity of 100.00%, and highest accuracy of 91.25%.

CONCLUSION: IVIM DWI-derived parameters add additional diagnostic value to conventional morphologic features. A combined diagnosis model is a promising imaging tool for predicting the origin of uterine adenocarcinoma, further contributing to therapeutic decision-making.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zhang Q, Ouyang H, Ye F, et al. Feasibility of intravoxel incoherent motion diffusion-weighted imaging in distinguishing adenocarcinoma originated from uterine corpus or cervix. Abdom Radiol (NY). 2021. PMID: 32671441. doi:10.1007/s00261-020-02586-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。