文献速递妇产影像US

糖尿病妊娠中使用自动分数肢体体积与二维尺寸参数估计胎儿体重

Fetal Weight Estimation Using Automated Fractional Limb Volume With 2-Dimensional Size Parameters in Diabetic Pregnancies.
PubMed 文献 · J Ultrasound Med · 2020-07-25

该初步研究纳入90例糖尿病妊娠孕妇,在分娩前7天内测量标准胎儿生物计量,并采用自动软件测量分数臂体积和分数大腿体积软组织参数,比较仅含二维尺寸参数的3种传统体重预测模型与含分数肢体体积的模型。含分数臂体积和分数大腿体积模型的随机误差更小,且估计体重在出生体重±10%以内的比例最高(均为91.1%)。

要点

  • 在糖尿病妊娠中,自动分数肢体体积模型估计体重在出生体重±10%以内的比例均为91.1%。
  • 分数臂体积模型随机误差6.2%、分数大腿体积模型6.9%,均优于传统二维模型。
  • Schild模型存在轻度低估,平均百分比差异为-3.8%。

核心结论

  • 在糖尿病妊娠队列中,将自动分数肢体体积测量加入传统二维生物计量与改进的体重预测相关。

研究设计与样本

  • 初步研究纳入90例糖尿病妊娠孕妇,其中孕前糖尿病占26.7%、妊娠期糖尿病占73.3%。
  • 在分娩前7天内测量标准胎儿生物计量,并采用自动软件(5D Limb Vol;Samsung Medison Co, Ltd, Seoul, Korea)测量分数臂体积和分数大腿体积软组织参数。
  • 将仅含二维尺寸参数的3种传统体重预测模型与含分数臂体积或分数大腿体积的模型进行比较。
  • 采用Student t检验评估系统误差,Pitman检验比较相关方差以评估随机误差,McNemar检验比较组间估计胎儿体重在出生体重±10%以内的比例。

诊断标准与关键数值

  • 所有预测模型均准确,但Schild等模型存在轻度低估,平均百分比差异为-3.8%。
  • 分数臂体积模型随机误差6.2%、分数大腿体积模型随机误差6.9%,均显著优于Hadlock等模型(7.8%)、INTERGROWTH-21st(8.0%)和Schild等模型(8.6%),P < .01。
  • 估计体重在出生体重±10%以内的比例:分数臂体积模型91.1%、分数大腿体积模型91.1%、Hadlock模型83.3%、INTERGROWTH-21st模型78.9%、Schild模型76.7%。

临床应用与阅片要点

  • 在糖尿病妊娠中,可考虑在传统二维生物计量基础上加入自动分数肢体体积测量以改进体重预测。
  • 分数臂体积与分数大腿体积模型的随机误差和估计体重在出生体重±10%以内的比例均优于仅含二维尺寸参数的模型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To examine the effect of adding automated fetal fractional limb volume (FLV) with conventional 2-dimensional (2D) fetal weight estimation procedures in a cohort of diabetic pregnancies.

METHODS: A pilot study of diabetic pregnancies measured standard fetal biometry within 7 days of delivery. Fractional arm volume (AVol) and fractional thigh volume (TVol) soft tissue parameters were measured with a commercially available automated software utility (5D Limb Vol; Samsung Medison Co, Ltd, Seoul, Korea). Three conventional weight prediction models that included only 2D size parameters were compared to FLV models that included AVol or TVol. Estimated and actual birth weight (BW) were assessed for the mean percent difference ± standard deviation of the percent differences. Systematic errors were evaluated by the Student t test, and random errors were compared by the Pitman test for correlated variances. The proportion of neonates with estimated fetal weight within 10% of BW was compared between groups by the McNemar test.

RESULTS: Ninety gravid women were enrolled with pregestational (26.7%) or gestational (73.3%) diabetes. All prediction models were accurate, with the exception of small underestimations by the model of Schild et al (-3.8%; Ultrasound Obstet Gynecol 2004; 23:30-35). Random errors for the AVol (6.2%) and TVol (6.9%) models were significantly more precise than the other 3 prediction models: Hadlock et al (7.8%; Am J Obstet Gynecol 1985; 151:333-337), INTERGROWTH-21st (8.0%; Ultrasound Obstet Gynecol 2017; 49:478-486), and Schild et al (8.6%; P < .01). The greatest proportion of cases with BW ±10% was also classified by the AVol (91.1%) and TVol (91.1%) models, followed by Hadlock (83.3%), INTERGROWTH-21st (78.9%), and Schild (76.7%) predictions.

CONCLUSIONS: The addition of automated FLV measurements to conventional 2D biometry was associated with improved weight predictions in this cohort of diabetic pregnancies.