子宫位置与盆腔内运动对子宫三维T2加权MRI图像质量的影响:短预扫描能否预测非诊断性图像质量?
这项回顾性研究纳入287例接受盆腔MRI(含3D-T2WI及由2D-T2WI和 cine 成像组成的短预扫描)的女性,评估子宫位置与盆腔内运动对3D-T2WI诊断质量的影响。非诊断性3D-T2WI见于42例(14.6%),其风险因素因子宫位置而异:子宫接触膀胱时明显尿流(调整OR=35.1),子宫被肠管包绕时严重呼吸及小肠运动(调整OR=68.4);两名技师用预扫描预测的敏感度为82.9%和68.3%,特异度为88.2%和93.9%。
要点
- 短预扫描(2D-T2WI联合cine成像)可预测子宫3D-T2WI的非诊断性图像质量,两名技师敏感度82.9%和68.3%、特异度88.2%和93.9%。
- 子宫接触膀胱时,明显尿流是非诊断性3D-T2WI的风险因素(调整OR=35.1)。
- 子宫被肠管包绕时,严重呼吸及小肠运动是非诊断性3D-T2WI的风险因素(调整OR=68.4)。
核心结论
- 盆腔内运动对3D-T2WI图像质量的影响随子宫位置不同而异,短预扫描可能有助于预测耗时且非诊断性的子宫3D-T2WI。
研究设计与样本
- 回顾性研究纳入287例接受盆腔MRI(含3D-T2WI及由2D-T2WI和cine成像组成的短预扫描)的女性。
- 由一名放射科医生将子宫3D-T2WI分为诊断性或非诊断性图像质量,并评估预扫描中的子宫位置与盆腔内运动。
- 采用多变量逻辑回归分析识别非诊断性3D-T2WI的预测因素,并由两名独立MRI技师验证预扫描的预测能力。
关键影像表现/征象
- 非诊断性3D-T2WI见于42例(14.6%),与膀胱内严重尿流(p < 0.001)、小肠运动(p = 0.039)及呼吸运动(p < 0.001)显著相关。
- 子宫接触膀胱时,明显尿流是非诊断性图像质量的风险因素(p < 0.001,调整OR=35.1)。
- 子宫被肠管包绕时,严重呼吸及小肠运动是非诊断性图像质量的风险因素(p < 0.001,调整OR=68.4)。
- 子宫接触椎体时未发现非诊断性图像质量的风险因素。
诊断标准与关键数值
- 两名技师使用预扫描预测非诊断性3D-T2WI的敏感度分别为82.9%和68.3%,特异度分别为88.2%和93.9%。
临床应用与阅片要点
- 阅片或安排子宫3D-T2WI时,可参考短预扫描中子宫位置及相应盆腔内运动情况预判非诊断性图像质量的风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate prescan findings of uterine position and intrapelvic motions that predict the non-diagnostic image quality of three-dimensional T2-weighted MRI (3D-T2WI) of the uterus.
METHODS: This retrospective study included 287 women who underwent pelvic MRI including 3D-T2WI and short prescans consisting of 2D-T2WI and cine imaging. One radiologist classified 3D-T2WI of the uterus as being of diagnostic or non-diagnostic image quality and evaluated the prescans regarding uterine position and intrapelvic motions. Multivariate logistic regression analysis was performed to identify predictors of non-diagnostic 3D-T2WI. The predictive ability of the prescans was verified by two independent MRI technologists.
RESULTS: Non-diagnostic 3D T2WI was found in 42 patients (14.6 %) and was significantly associated with severe motions of urinary flow in the bladder (p < 0.001), small bowel (p = 0.039), and respiration (p < 0.001). In the multivariate analysis of uterine position and intrapelvic motions, risk factors for the non-diagnostic image quality were prominent urinary flow when the uterus contacted the bladder (p < 0.001, adjusted odds ratio = 35.1) and severe respiratory and small bowel motions when the uterus was surrounded by the bowel (p < 0.001, adjusted odds ratio = 68.4). No risk factors were found for the uterus contacting the vertebrae. With these predictors, the prescans demonstrated a sensitivity of 82.9 and 68.3 %, and specificity of 88.2 and 93.9 % for the non-diagnostic 3D-T2WI by the two technologists, respectively.
CONCLUSION: Intrapelvic motions have a different effect on the image quality of 3D-T2WI depending on the uterine position, and short prescans may be useful in predicting time-consuming non-diagnostic 3D-T2WI of the uterus.
引用
- Tsuboyama T, Takei O, Okada A, et al. Effect of uterine position and intrapelvic motions on the image quality of 3D T2-weighted MRI of the uterus: Can short prescans predict the non-diagnostic image quality? Eur J Radiol. 2020. PMID: 32712496. doi:10.1016/j.ejrad.2020.109186
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。