文献速递泌尿生殖腹部CT

对比增强计算机断层扫描新型数学分析与肾闪烁显像评估肾功能的前瞻性研究

A prospective study of novel mathematical analysis of the contrast-enhanced computed tomography vs renal scintigraphy in renal function evaluation.
PubMed 文献 · Eur J Radiol · 2020-07-08

前瞻性单臂研究纳入97例需行99mTc-DTPA动态肾闪烁显像的患者,均行增强CT数学分析(MACT),由单人对闪烁显像结果设盲操作。CT结果与肾闪烁显像结果相似,Pearson相关系数0.945(P<0.001),双肾肾血浆流量也观察到高度相似性(0.815,P<0.001)。作者认为MACT可行、有效且安全,结果与肾闪烁显像密切关联,可容易地整合到外科实践中。

要点

  • MACT与肾闪烁显像评估分肾功能高度相关,Pearson相关系数0.945(P<0.001)。
  • 双肾肾血浆流量在两种方法间也呈高度相似性,相关系数0.815(P<0.001)。
  • 作者认为MACT可行、有效且安全,可容易地整合到外科实践中。

核心结论

  • MACT在评估肾功能方面被证明可行、有效且安全。
  • MACT结果与肾闪烁显像结果密切关联,可容易地整合到外科实践中。

研究设计与样本

  • 前瞻性单臂研究,共纳入97例患者,平均年龄50.9岁(范围23-78岁),其中女性65例、男性32例。
  • 纳入患者均为被推荐行99mTc-DTPA动态肾闪烁显像者,闪烁显像后所有患者均行增强CT数学分析(MACT)。
  • MACT由单人(SK)操作,对肾闪烁显像结果设盲;所有患者于2016-2018年间完成肾闪烁显像和增强CT以进一步行MACT。

诊断标准与关键数值

  • CT结果与肾闪烁显像结果相似,Pearson相关系数为0.945(P<0.001)。
  • 双肾肾血浆流量在两种方法间观察到高度相似性,相关系数为0.815(P<0.001)。

临床应用与阅片要点

  • 作者认为MACT可行、有效且安全,其结果与肾闪烁显像密切关联,可容易地整合到外科实践中。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: whilst renal scintigraphy (RS) can be associated with interobserver variability, it remains the standard method of evaluating split renal function.

AIM: to compare the efficacy of the novel technique of kidney function assessment and renal scintigraphy.

METHOD: for this prospective single-arm study we recruited patients who were recommended dynamic renal scintigraphy with 99mTc-DTPA (diethylenetriaminepentacetate). After scintigraphy, mathematical analysis of computed tomography (MACT) was done in all patients, by a single person (SK) blinded to RS results.

RESULTS: the study included a total of 97 patients with mean age of 50.9 (range, 23-78) years. From this sample, 65 were females and 32 males. All patients underwent both RS and contrast-enhanced computed tomography for further MACT in 2016-2018. CT results were found to be similar to renal scintigraphy results with Pearson correlation coefficient of 0.945 (р < 0.001). Substantial similarities in renal plasma flow for both kidneys were also observed (0.815, р < 0.001).

CONCLUSION: MACT proved feasible, effective and safe in estimating renal function. Its results are closely correlated with RS findings and could be easily integrated into surgical practice.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Fiev D, Proskura A, Khokhlachev S, et al. A prospective study of novel mathematical analysis of the contrast-enhanced computed tomography vs renal scintigraphy in renal function evaluation. Eur J Radiol. 2020. PMID: 32663764. doi:10.1016/j.ejrad.2020.109169

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。