文献速递泌尿生殖介入CTMR

在肌层浸润性膀胱癌模体中量化和校正1.5 T与3 T扩散加权MRI的几何失真以用于放疗计划

Quantification and correction of distortion in diffusion-weighted MRI at 1.5 and 3 T in a muscle-invasive bladder cancer phantom for radiotherapy planning.
PubMed 文献 · Br J Radiol · 2020-08-05

研究设计模拟肌层浸润性膀胱癌的模体,比较CT、扩散加权MRI与T2加权MRI上基准标记位置,量化扩散加权MRI失真并评估公开软件校正磁敏感相关失真的效果。结果显示3 T下CT与表观扩散系数图最大偏差6.3 mm,校正后降至1.8 mm;1.5 T下分别为3.9 mm和1.7 mm。结论为已建立的校正方法可将失真降至2 mm以内,作者认为需进一步研究以实现基于扩散加权MRI的个体化自适应图像引导放疗。

要点

  • 扩散加权MRI在3 T下几何失真可超过6 mm,在1.5 T下可超过3 mm。
  • 经公开软件校正磁敏感相关失真后,两种场强下偏差均降至2 mm以内。
  • CT与T2加权MRI基准标记位置在3 T下一致至1.2 mm以内,在1.5 T下一致至1.8 mm以内。

核心结论

  • 模拟膀胱的扩散加权MRI几何失真在3 T下初始超过6 mm、在1.5 T下超过3 mm,已建立的校正方法使两者均降至2 mm以内。
  • 作者认为需进一步研究以实现基于扩散加权MRI的肌层浸润性膀胱癌个体化自适应图像引导放疗。

研究设计与样本

  • 设计模拟肌层浸润性膀胱癌的模体,并使用CT、扩散加权MRI和T2加权MRI进行成像。
  • 比较不同成像方式间基准标记的位置,并评估公开软件对磁敏感相关失真的校正效果。

关键影像表现/征象

  • CT与T2加权MRI上基准标记位置在3 T下一致至1.2 mm以内,在1.5 T下一致至1.8 mm以内。

诊断标准与关键数值

  • CT与表观扩散系数图之间最大偏差在3 T下为6.3 mm,校正失真后降至1.8 mm。
  • CT与表观扩散系数图之间最大偏差在1.5 T下为3.9 mm,校正失真后降至1.7 mm。

临床应用与阅片要点

  • 作者认为扩散加权MRI的失真可被充分减轻以纳入放疗流程。
  • 作者认为需进一步研究以实现基于扩散加权MRI的肌层浸润性膀胱癌个体化自适应图像引导放疗。

局限性

  • 作者指出需进一步研究以实现基于扩散加权MRI的肌层浸润性膀胱癌个体化自适应图像引导放疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Limited visibility of post-resection muscle-invasive bladder cancer (MIBC) on CT hinders radiotherapy dose escalation of the residual tumour. Diffusion-weighted MRI (DW-MRI) visualises areas of high tumour burden and is increasingly used within diagnosis and as a biomarker for cancer. DW-MRI could, therefore, facilitate dose escalation, potentially via dose-painting and/or accommodating response. However, the distortion inherent in DW-MRI could limit geometric accuracy. Therefore, this study aims to quantify DW-MRI distortion via imaging of a bladder phantom.

METHODS: A phantom was designed to mimic MIBC and imaged using CT, DW-MRI and T2W-MRI. Fiducial marker locations were compared across modalities and publicly available software was assessed for correction of magnetic susceptibility-related distortion.

RESULTS: Fiducial marker locations on CT and T2W-MRI agreed within 1.2 mm at 3 T and 1.8 mm at 1.5 T. The greatest discrepancy between CT and apparent diffusion coefficient (ADC) maps was 6.3 mm at 3 T, reducing to 1.8 mm when corrected for distortion. At 1.5 T, these values were 3.9 mm and 1.7 mm, respectively.

CONCLUSIONS: Geometric distortion in DW-MRI of a model bladder was initially >6 mm at 3 T and >3 mm at 1.5 T; however, established correction methods reduced this to <2 mm in both cases.

ADVANCES IN KNOWLEDGE: A phantom designed to mimic MIBC has been produced and used to show distortion in DW-MRI can be sufficiently mitigated for incorporation into the radiotherapy pathway. Further investigation is therefore warranted to enable individually adaptive image-guided radiotherapy of MIBC based upon DW-MRI.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Rogers J, Sherwood V, Wayte SC, et al. Quantification and correction of distortion in diffusion-weighted MRI at 1.5 and 3 T in a muscle-invasive bladder cancer phantom for radiotherapy planning. Br J Radiol. 2020. PMID: 32706981. doi:10.1259/bjr.20190710

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。