文献速递腹部技术与安全MR

体素内不相干运动成像、扩散峰度成像与常规扩散加权成像预测结直肠癌肝转移化疗反应比较

Comparison of intravoxel incoherent motion imaging, diffusion kurtosis imaging, and conventional DWI in predicting the chemotherapeutic response of colorectal liver metastases.
PubMed 文献 · Eur J Radiol · 2020-06-26

前瞻性研究纳入40例接受标准一线化疗的结直肠癌肝转移患者,化疗前1周内及化疗后2–3周、6–8周行MRI,比较ADC、IVIM及DKI参数预测化疗反应的价值。应答组15例、无应答组25例,低基线ADC、Dslow、D值及高基线K值与化疗良好应答独立相关,联合全部显著参数AUC为0.867。

要点

  • 化疗前低基线ADC、Dslow、D值及高基线K值与结直肠癌肝转移化疗良好应答独立相关。
  • 联合ADC、Dslow、D、K全部显著参数预测化疗应答的AUC为0.867。
  • 化疗后ADC、Dslow、D值呈上升趋势、K值呈下降趋势,但差异均无统计学意义(P>0.05)。

诊断标准与关键数值

  • 应答组(完全缓解和部分缓解)15例 vs 无应答组(疾病稳定和疾病进展)25例。
  • 低基线ADC值(P=0.001)、低基线Dslow值(P<0.001)、低基线D值(P=0.003)及高基线K值(P=0.002)与化疗良好应答独立相关。
  • 联合全部显著参数的AUC为0.867。
  • 化疗后ADC、Dslow、D值均呈上升趋势、K值呈下降趋势,但差异无统计学意义(P>0.05)。

临床应用与阅片要点

  • 化疗前可测量ADC、Dslow、D及K值,用于预测结直肠癌肝转移患者对标准一线化疗的应答。
  • ADC、Dslow、D值越低、K值越高,提示化疗良好应答的可能性越大。
  • 联合ADC、Dslow、D、K四项参数可提高预测化疗应答的诊断性能(AUC 0.867)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the usefulness and performance of intravoxel incoherent motion imaging (IVIM) with diffusion kurtosis imaging (DKI) and conventional DWI for predicting the chemotherapeutic response of colorectal liver metastases (CRLMs).

METHOD: A prospective study was conducted. Up to February 2018, forty consecutive patients treated with the standard first-line chemotherapy regimens were enrolled. MRI was performed within 1 week before chemotherapy, as well as 2-3 weeks and 6-8 weeks after chemotherapy. The apparent diffusion coefficient map, IVIM and DKI parameter maps were calculated using a prototype postprocessing software. The response was assessed by the Response Evaluation Criteria in Solid Tumors. The parameters were compared between the responding group (complete and partial response) and the nonresponding group (stable and progressive disease).

RESULTS: A total of 15 responding and 25 nonresponding patients were evaluated. Low baseline ADC, Dslow, and D values (P = 0.001, <0.001, and =0.003, respectively) and a high baseline K value (P = 0.002) were independently associated with a good response to chemotherapy. The combination of all the significant parameters yielded an AUC of 0.867. After treatment, the ADC, Dslow, and D values all showed an upward trend, while the K value showed a decreasing trend, but there were no significant differences (P > 0.05).

CONCLUSION: The study showed that the pretreatment IVIM (Dslow), DKI (D and K), and conventional DWI (ADC) parameters all demonstrated a good diagnostic performance in predicting the chemotherapeutic response of CRLMs.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang H, Li W, Fu C, et al. Comparison of intravoxel incoherent motion imaging, diffusion kurtosis imaging, and conventional DWI in predicting the chemotherapeutic response of colorectal liver metastases. Eur J Radiol. 2020. PMID: 32659615. doi:10.1016/j.ejrad.2020.109149

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。