文献速递骨肌乳腺技术与安全MR

短时反转恢复脂肪抑制同步多层扩散加权成像在骨转移乳腺癌中的应用

Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer.
PubMed 文献 · Eur J Radiol · 2020-06-20

在23例骨转移乳腺癌患者中于1.5 T比较同步多层扩散加权成像(mb-DWI)与常规DWI(c-DWI)的短时反转恢复脂肪抑制图像质量与ADC值,mb-DWI扫描时间较c-DWI缩短48%(每站1分58秒 vs 3分45秒),主观图像质量、伪影及病灶显示相似,但肝脏、竖脊肌及骨转移灶ADC值较低。

要点

  • mb-DWI较c-DWI每站扫描时间缩短48%(1分58秒 vs 3分45秒),主观图像质量与伪影相似。
  • 骨转移灶ADC值mb-DWI较c-DWI低6.4%(95%CI 5.4%-7.4%,p<0.001)。
  • 肝脏及竖脊肌ADC值mb-DWI亦低于c-DWI,判读ADC时需注意序列差异。

关键影像表现/征象

  • mb-DWI与c-DWI主观图像质量相似(3.8 vs 3.7,p=0.70)。
  • mb-DWI与c-DWI伪影数量(50 vs 56)及严重程度(4.6 vs 4.7,p=0.11)相似。
  • mb-DWI与c-DWI骨转移灶显示相似(4.2 vs 4.4,p=0.31)。

诊断标准与关键数值

  • 骨转移灶ADC值mb-DWI较c-DWI低6.4%(95%CI 5.4%-7.4%,p<0.001)。
  • 肝脏平均ADC值mb-DWI 0.5×10-3 mm2/s vs c-DWI 0.7×10-3 mm2/s(p=0.002)。
  • 竖脊肌平均ADC值mb-DWI 1.3×10-3 mm2/s vs c-DWI 1.5×10-3 mm2/s(p<0.001)。

临床应用与阅片要点

  • mb-DWI可大幅缩短全身DWI扫描时间(每站1分58秒 vs 3分45秒,缩短48%)。
  • 判读mb-DWI的ADC值时需注意其肝脏、竖脊肌及骨转移灶ADC值低于c-DWI。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To compare image quality and ADC values of simultaneous multislice diffusion-weighted imaging (mb-DWI) with that of conventional DWI (c-DWI) using short tau inversion recovery fat saturation (STIR) in women with bone-metastasizing breast cancer.

METHOD: c-DWI and mb-DWI were acquired at 1.5 T in 23 breast cancer patients from skull base to mid thighs. mb-DWI was compared to c-DWI in terms of subjective image quality, artefacts and bone metastasis lesion conspicuity assessed on a 5-point Likert scale. ADC values of different organs as well as bone metastasis ADC values were compared between c-DWI and mb-DWI.

RESULTS: mb-DWI reduced scan time by 48 % compared with c-DWI (1 min 58 s vs. 3 min 45 s per station). mb-DWI provided similar subjective image quality (3.8 vs. 3.7, p = 0.70), number of artefacts (50 vs. 56), severity of these (4.6 vs. 4.7, p = 0.11), and lesion conspicuity (4.2 vs. 4.4, p = 0.31) compared to c-DWI. mb-DWI showed lower mean ADC values in liver (0.5 × 10-3 mm2/s vs. 0.7 × 10-3 mm2/s, p = 0.002) and erector spine muscle (1.3 × 10-3 mm2/s vs. 1.5 × 10-3 mm2/s, p < 0.001). Bone metastasis ADC values from mb-DWI were 6.4 % lower than c-DWI (95 % confidence interval: 5.4%-7.4%, p < 0.001).

CONCLUSIONS: mb-DWI provides similar subjective image quality to c-DWI with the same level of artefacts. Although bone metastasis ADC values were lower, mb-DWI can substantially reduce scan times of whole-body DWI in women with bone-metastasizing breast cancer.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Buus TW, Sivesgaard K, Jensen AB, et al. Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer. Eur J Radiol. 2020. PMID: 32619754. doi:10.1016/j.ejrad.2020.109142

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。