文献速递腹部技术与安全CT

虚拟单能图像在对比剂减量腹部光谱探测器CT中保持诊断可评估性

Virtual monoenergetic images preserve diagnostic assessability in contrast media reduced abdominal spectral detector CT.
PubMed 文献 · Br J Radiol · 2020-07-24

回顾性纳入78例腹部光谱探测器CT检查者,对比剂减量组(44例次,50 ml)与标准剂量组(44例次,100 ml)按有效体径匹配;减量组重建40keV虚拟单能图像后,除器官对比度、整体可评估性和图像噪声仍逊于标准剂量常规图像外,其余标准等效或更优,88.6%/94.2%/95.4%的病例获得合格或优秀评分。

要点

  • 对比剂减量常规图像各项定量与定性指标均逊于标准剂量图像。
  • 减量方案加建40keV虚拟单能图像后,淋巴结与肌肉衰减和标准剂量图像相似。
  • 减量方案40keV虚拟单能图像在器官对比度、整体可评估性和图像噪声上仍逊于标准剂量图像。

核心结论

  • 40keV虚拟单能图像可抵消对比剂减量腹部光谱探测器CT的对比度下降,有助于诊断评估。

研究设计与样本

  • 回顾性纳入78例腹部光谱探测器CT检查者,减量组41例共44例次(50 ml对比剂),标准剂量组37例共44例次(100 ml对比剂),两组按有效体径匹配。
  • 重建减量组常规图像、标准剂量组常规图像及减量组40keV虚拟单能图像,基于ROI评估肝脏、胰腺、肾脏、淋巴结、腰大肌、主动脉和门静脉的衰减与信噪比。
  • 计算淋巴结与主动脉/门静脉的对比噪声比,并由两名读片者用4级Likert量表评估器官/血管对比度、淋巴结轮廓、图像噪声和整体可评估性。

诊断标准与关键数值

  • 减量组常规图像在所有定量与定性标准上均逊于标准剂量图像。
  • 减量组40keV虚拟单能图像与标准剂量图像淋巴结和肌肉衰减相似(p=0.83、0.17),其余ROI衰减更高(p≤0.05)。
  • 减量组40keV虚拟单能图像与标准剂量图像信噪比相当(p范围0.23–0.99),淋巴结对比噪声比最高(p≤0.05)。
  • 定性评分上,减量组40keV虚拟单能图像除器官对比度、整体可评估性和图像噪声外(标准剂量图像更优,p≤0.05),其余标准等效或更高;减量组40keV虚拟单能图像在88.6%/94.2%/95.4%的病例中获得合格或优秀评分。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate if low-keV virtual monoenergetic images (VMI40keV) from abdominal spectral detector CT (SDCT) with reduced intravenous contrast media application (RCM) provide abdominal assessment similar to conventional images with standard contrast media (SCM) dose.

METHODS: 78 patients with abdominal SDCT were retrospectively included: 41 patients at risk for adverse reactions who received 44 RCM examinations with 50 ml and 37 patients who underwent 44 SCM examinations with 100 ml of contrast media (CM) and who were matched for effective body diameters. RCM, SCM images and RCM-VMI40keV were reconstructed. Attenuation and signal-to-noise ratio (SNR) of liver, pancreas, kidneys, lymph nodes, psoas muscle, aorta and portal vein were assessed ROIs-based. Contrast-to-noise ratios (CNR) of lymph nodes vs aorta/portal vein were calculated. Two readers evaluated organ/vessel contrast, lymph node delineation, image noise and overall assessability using 4-point Likert scales.

RESULTS: RCM were inferior to SCM images in all quantitative/qualitative criteria. RCM-VMI40keV and SCM images showed similar lymph node and muscle attenuation (p = 0.83,0.17), while for all other ROIs, RCM-VMI40keV showed higher attenuation (p ≤ 0.05). SNR was comparable between RCM-VMI40keV and SCM images (p range: 0.23-0.99). CNR of lymph nodes was highest in RCM-VMI40keV (p ≤ 0.05). RCM-VMI40keV received equivalent or higher scores than SCM in all criteria except for organ contrast, overall assessability and image noise, where SCM were superior (p ≤ 0.05). However, RCM-VMI40keV received proper or excellent scores in 88.6/94.2/95.4% of the referring cases.

CONCLUSIONS: VMI40keV counteract contrast deterioration in CM reduced abdominal SDCT, facilitating diagnostic assessment.

ADVANCES IN KNOWLEDGE: SDCT-derived VMI40keV provide adequate depiction of vessels, organs and lymph nodes even at notable CM reduction.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Lennartz S, Große Hokamp N, Zäske C, et al. Virtual monoenergetic images preserve diagnostic assessability in contrast media reduced abdominal spectral detector CT. Br J Radiol. 2020. PMID: 32644824. doi:10.1259/bjr.20200340

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。