文献速递腹部儿科影像MR

肝实质扩散张量成像参数用于鉴别胆道闭锁与Alagille综合征的评估

Assessment of Diffusion Tensor Imaging Parameters of Hepatic Parenchyma for Differentiation of Biliary Atresia from Alagille Syndrome.
PubMed 文献 · Korean J Radiol · 2020-07-27

本研究纳入32例胆道闭锁(BA)和12例Alagille综合征(ALGS)婴儿,评估肝实质扩散张量成像(DTI)参数对两者的鉴别价值。结果显示BA组肝平均弥散率(MD)显著低于ALGS组,FA显著高于ALGS组;MD阈值1.77和1.79×10-3 mm²/s鉴别BA与ALGS的准确率分别为82%和79%,AUC分别为0.90和0.91。作者认为肝DTI参数是有前景的无创鉴别工具。

要点

  • BA组肝MD显著低于ALGS组,两位读者测量值均一致(r=0.8,p=0.001)。
  • MD阈值1.77和1.79×10-3 mm²/s鉴别BA与ALGS的AUC达0.90和0.91。
  • BA组肝FA显著高于ALGS组,但FA阈值鉴别AUC仅0.69和0.68。

关键影像表现/征象

  • BA组肝MD为1.56±0.20和1.63±0.2×10-3 mm²/s,ALGS组为1.84±0.04和1.79±0.03×10-3 mm²/s,BA组显著低于ALGS组(r=0.8,p=0.001)。
  • BA组肝FA为0.34±0.04和0.36±0.04,ALGS组为0.30±0.06和0.31±0.05,BA组显著高于ALGS组(p=0.01、0.02;r=0.80,p=0.001)。

诊断标准与关键数值

  • MD阈值1.77×10-3 mm²/s鉴别BA与ALGS的准确率为82%、AUC为0.90(读者一)。
  • MD阈值1.79×10-3 mm²/s鉴别BA与ALGS的准确率为79%、AUC为0.91(读者二)。
  • FA阈值0.30鉴别BA与ALGS的准确率为75%、AUC为0.69(读者一)。
  • FA阈值0.28鉴别BA与ALGS的准确率为82%、AUC为0.68(读者二)。

临床应用与阅片要点

  • 作者认为肝DTI参数可能作为鉴别BA与ALGS的附加无创影像工具。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess diffusion tensor imaging (DTI) parameters of the hepatic parenchyma for the differentiation of biliary atresia (BA) from Alagille syndrome (ALGS).

MATERIALS AND METHODS: This study included 32 infants with BA and 12 infants with ALGS groups who had undergone DTI. Fractional anisotropy (FA) and mean diffusivity (MD) of the liver were calculated twice by two separate readers and hepatic tissue was biopsied. Statistical analyses were performed to determine the mean values of the two groups. The optimum cut-off values for DTI differentiation of BA and ALGS were calculated by receiver operating characteristic (ROC) analysis.

RESULTS: The mean hepatic MD of BA (1.56 ± 0.20 and 1.63 ± 0.2 × 10-3 mm²/s) was significantly lower than that of ALGS (1.84 ± 0.04 and 1.79 ± 0.03 × 10-3 mm²/s) for both readers (r = 0.8, p = 0.001). Hepatic MD values of 1.77 and 1.79 × 10-3 mm²/s as a threshold for differentiating BA from ALGS showed accuracies of 82 and 79% and area under the curves (AUCs) of 0.90 and 0.91 for both readers, respectively. The mean hepatic FA of BA (0.34 ± 0.04 and 0.36 ± 0.04) was significantly higher (p = 0.01, 0.02) than that of ALGS (0.30 ± 0.06 and 0.31 ± 0.05) for both readers (r = 0.80, p = 0.001). FA values of 0.30 and 0.28 as a threshold for differentiating BA from ALGS showed accuracies of 75% and 82% and AUCs of 0.69 and 0.68 for both readers, respectively.

CONCLUSION: Hepatic DTI parameters are promising quantitative imaging parameters for the detection of hepatic parenchymal changes in BA and ALGS and may be an additional noninvasive imaging tool for the differentiation of BA from ALGS.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Abdel Razek AAK, Abdalla A, Elfar R, et al. Assessment of Diffusion Tensor Imaging Parameters of Hepatic Parenchyma for Differentiation of Biliary Atresia from Alagille Syndrome. Korean J Radiol. 2020. PMID: 32729270. doi:10.3348/kjr.2019.0824

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。