本研究纳入84例接受含DWI序列(b值0-50-500-700)MRI检查的患者,分为胆道梗阻组58例(实验室检查异常)与无梗阻组26例(实验室检查正常)。ADC图 cutoff 值353×10⁻⁶ mm²/s 鉴别两组敏感度92.3%、特异度81%、准确率91.9%,且ADC值与胆管扩张程度、胆红素水平及b700信号持续存在相关。
要点
- ADC图 cutoff 值353×10⁻⁶ mm²/s 鉴别梗阻与无梗阻胆道,敏感度92.3%、特异度81%、准确率91.9%。
- 梗阻组58例中38例b700图像上胆道信号持续存在,无梗阻组26例中仅4例持续存在。
- ADC值与胆管扩张程度、胆红素水平及b700信号持续存在相关,可用于辅助判断。
核心结论
- DWI能够区分胆道梗阻与无梗阻患者,且不受胆管扩张程度影响,并与临床及实验室检查结果相关。
研究设计与样本
- 研究纳入84例接受MRI with DWI(b值0-50-500-700)检查的患者,男40例、女44例,平均年龄56.4±15.1岁。
- 按实验室检查分为梗阻组58例(实验室检查异常)与无梗阻组26例(实验室检查正常)。
- 实验室检查包括总胆红素、碱性磷酸酶和γ-谷氨酰转移酶;计算中位ADC值并与实验室检查及胆管扩张程度(无、中度、重度)进行相关性分析。
- 评估胆道在DWI(b500和b700)上信号持续存在情况,并检验胆红素值与胆道ADC值及b700信号持续存在的相关性。
关键影像表现/征象
- 梗阻组58例中,胆管重度扩张15例、中度扩张24例、无明显扩张19例;38例在b700图像上信号持续存在。
- 无梗阻组26例中,无扩张23例、中度扩张3例;4例在b700图像上信号持续存在。
- 胆管扩张程度、胆红素水平、b700信号持续存在与ADC图值之间存在相关性。
诊断标准与关键数值
- ADC图 cutoff 值353×10⁻⁶ mm²/s 鉴别梗阻组与无梗阻组,敏感度92.3%、特异度81%、准确率91.9%。
临床应用与阅片要点
- 对怀疑胆道梗阻的患者,可结合DWI b700信号持续存在及ADC图测量辅助鉴别梗阻与非梗阻性胆管。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study sought to evaluate the role of diffusion-weighted imaging (DWI) in differentiation between obstructed and unobstructed bile ducts in patients undergoing magnetic resonance imaging (MRI).
METHODS: Eighty-four patients, 40 males and 44 females (mean age: 56.4 ± 15.1 years), undergoing MRI with DWI (0-50-500-700) were evaluated and divided into two groups: 58 with abnormal laboratory tests (obstructed group) and 26 with normal laboratory values (unobstructed group). Laboratory tests were total bilirubin, alkaline phosphatase, and gamma-glutamyltransferase. Median ADC values were calculated and correlated with laboratory tests and degree of bile-duct dilatation (absent, moderate, or severe). The persistence of signal on DWI (b500 and b700) in the biliary tract was evaluated. Bilirubin values were tested for correlation with bile-duct ADC values and persistence of b700 signal. For statistical analysis, Student t test, chi-square test and Wilcoxon-Mann-Whitney test were used. ADC maps were plotted for three levels of the biliary tree, and a receiver operating characteristic (ROC) curve was calculated.
RESULTS: In the obstructed group, 15 patients had severe dilatation, 24 had moderate dilatation, and 19 had no appreciable dilatation; 38 patients had persistent signal on b700 images. In the unobstructed group, 23 patients had no dilatation and 3 had moderate dilatation; 4 patients had persistent signal on b700 images. Correlation was found between degree of bile-duct dilatation, bilirubin levels, persistence of b700 signal, and ADC map values. The calculated ADC map cutoff value (353 10-6 mm2/s) was able to differentiate the obstructed and unobstructed groups with 92.3% sensitivity, 81% specificity, and 91.9% accuracy.
CONCLUSIONS: DWI is able to distinguish patients with obstructed versus unobstructed bile ducts, regardless of the degree of dilatation, correlating with clinical and laboratory findings.
引用
- Paro EDL, Puchnick A, Szejnfeld J, et al. Use of diffusion-weighted imaging in the noninvasive diagnostic of obstructed biliary ducts. Abdom Radiol (NY). 2020. PMID: 32666232. doi:10.1007/s00261-020-02636-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。