文献速递心血管介入DSA

低剂量与传统剂量方案在有创冠状动脉造影中估计辐射暴露的随机比较(ERICA试验):先导研究

A randomized comparison of estimated radiation exposure between Low and conventional dose protocol during invasive coronary angiography (ERICA trial): Pilot study.
PubMed 文献 · Eur J Radiol · 2020-06-06

研究将103例连续接受冠状动脉造影的患者随机分为低剂量方案(LDP)与传统剂量方案(CDP),LDP在透视时采用每秒10帧、电影造影时辐射剂量为CDP的一半。结果显示LDP组总剂量面积乘积和空气比释动能均显著低于CDP组,且图像质量无显著下降。作者认为LDP可能是保护患者和医护人员免受辐射危害的可行策略。

要点

  • 低剂量方案(LDP)较传统剂量方案(CDP)显著降低总剂量面积乘积:LDP 1980.1 ± 1163.7 vs CDP 3434.2 ± 2188.1 μGym²(p=0.001)。
  • LDP组总空气比释动能显著低于CDP组:279.6 ± 159.3 vs 493.8 ± 280.6 mGy(p<0.001)。
  • LDP与CDP在图像质量上无显著差异,未明显损失诊断信息。

诊断标准与关键数值

  • 总DAP:LDP组1980.1 ± 1163.7 μGym² vs CDP组3434.2 ± 2188.1 μGym²,p=0.001。
  • 总AK:LDP组279.6 ± 159.3 mGy vs CDP组493.8 ± 280.6 mGy,p<0.001。
  • 图像质量采用Likert评分量表由独立放射科医生评估,两组间无显著差异。

临床应用与阅片要点

  • 作者认为LDP可能是保护患者和医护人员免受导管室辐射危害的可行策略。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Radiation exposure during coronary angiography is potentially harmful to patients and operators. However, there are limited data on the effects of a low-dose radiation angiography. We evaluated the feasibility and effectiveness of a reduced radiation dose protocol during invasive coronary angiography.

METHODS: One hundred three consecutive patients who underwent coronary angiography were enrolled and randomized to low- or conventional dose protocols (LDP versus CDP). The LDP consists of 10 frames per second during fluoroscopy and half the radiation dose of CDP during cineangiography. Image quality was assessed using a Likert rating scale by an independent radiologist. The radiation dose was estimated with dose-area product (DAP) and air-kerma (AK).

RESULTS: Body weight and waist circumference are well correlated with the level of DAP and AK. Exposure time and total images and frame counts in cineangiography were similar in both groups. There was a marked reduction of the estimated radiation dose (DAP and AK) in the LDP group compared to the CDP group without significant compromise in image quality (total DAP: LDP 1980.1 ± 1163.7 vs. CDP 3434.2 ± 2188.1 μGym2 p = 0.001; total AK: 279.6 ± 159.3 vs. 493.8 ± 280.6 mGy, p < 0.001).

CONCLUSION: The LDP reduced the total estimated radiation dose compared to the CDP without a significant loss of diagnostic information. A LDP may be a viable strategy to protect patients and medical staff from the hazards of radiation in the cardiac catheterization laboratory.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Park SM, Kim HC, Lee MS, et al. A randomized comparison of estimated radiation exposure between Low and conventional dose protocol during invasive coronary angiography (ERICA trial): Pilot study. Eur J Radiol. 2020. PMID: 32599497. doi:10.1016/j.ejrad.2020.109120

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。