文献速递心血管MR

定量T1 mapping检测再灌注急性心肌梗死微血管阻塞:与延迟钆增强成像的比较

Quantitative T1 Mapping for Detecting Microvascular Obstruction in Reperfused Acute Myocardial Infarction: Comparison with Late Gadolinium Enhancement Imaging.
PubMed 文献 · Korean J Radiol · 2020-01-01

该研究纳入20例再灌注治疗后行1.5T心脏磁共振的急性心肌梗死患者,比较初始T1 mapping、增强后T1 mapping与延迟钆增强(LGE)成像检测和测量微血管阻塞(MVO)面积。结果显示初始T1 mapping检测MVO的检出率为90%(18/20),与LGE测得的MVO面积一致性高(一致性相关系数0.770);增强后T1 mapping检出率仅50%(10/20)且低估MVO面积。作者认为初始T1 mapping是检测梗死心肌内MVO的有用工具。

要点

  • 初始T1 mapping对MVO的检出率为90%(18/20),增强后T1 mapping仅50%(10/20)。
  • 初始T1 mapping与LGE测量的MVO面积一致性高,一致性相关系数为0.770。
  • 增强后T1 mapping低估MVO面积,与LGE的一致性相关系数仅0.375。

关键影像表现/征象

  • 初始T1图上MVO、梗死心肌和远程心肌的平均T1值分别为1013.5±58.5、1240.9±55.8(p<0.001)和1062.2±55.8 ms(p=0.169)。
  • 增强后T1图上MVO、梗死心肌和远程心肌的平均T1值分别为466.7±26.8、399.1±21.3和585.2±21.3 ms(p<0.001)。
  • 20个MVO中,初始T1图检出18个(90%),增强后T1图检出10个(50%)。
  • LGE、初始T1图和增强后T1图上MVO面积均值分别为134.1±81.2、133.7±80.4和117.1±53.3 mm²。
  • LGE、初始T1图和增强后T1图上MVO面积中位数(四分位距)分别为128.0(58.1-215.4)、110.5(67.7-227.9)和143.0(76.7-155.3)mm²(p=0.002)。

诊断标准与关键数值

  • MVO定义为LGE低信号区或T1图上视觉可区分的T1值区域。
  • 初始T1 mapping检测MVO的检出率为90%(18/20)。
  • 增强后T1 mapping检测MVO的检出率为50%(10/20)。
  • 初始T1 mapping与LGE测量MVO面积的一致性相关系数为0.770。
  • 增强后T1 mapping与LGE测量MVO面积的一致性相关系数为0.375;初始与增强后T1 mapping之间的一致性相关系数为0.565。

临床应用与阅片要点

  • 初始T1 mapping可用于检测梗死心肌内的MVO,其测值与LGE测值一致性高。
  • 增强后T1 mapping对MVO检出率低且低估MVO面积。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare native and post-contrast T1 mapping with late gadolinium enhancement (LGE) imaging for detecting and measuring the microvascular obstruction (MVO) area in reperfused acute myocardial infarction (MI).

MATERIALS AND METHODS: This study included 20 patients with acute MI who had undergone 1.5T cardiovascular magnetic resonance imaging (CMR) after reperfusion therapy. CMR included cine imaging, LGE, and T1 mapping (modified look-locker inversion recovery). MI size was calculated from LGE by full-width at half-maximum technique. MVO was defined as an area with low signal intensity (LGE) or as a region of visually distinguishable T1 values (T1 maps) within infarcted myocardium. Regional T1 values were measured in MVO, infarcted, and remote myocardium on T1 maps. MVO area was measured on and compared among LGE, native, and post-contrast T1 maps.

RESULTS: The mean MI size was 27.1 ± 9.7% of the left ventricular mass. Of the 20 identified MVOs, 18 (90%) were detected on native T1 maps, while 10 (50%) were recognized on post-contrast T1 maps. The mean native T1 values of MVO, infarcted, and remote myocardium were 1013.5 ± 58.5, 1240.9 ± 55.8 (p < 0.001), and 1062.2 ± 55.8 ms (p = 0.169), respectively, while the mean post-contrast T1 values were 466.7 ± 26.8, 399.1 ± 21.3, and 585.2 ± 21.3 ms, respectively (p < 0.001). The mean MVO areas on LGE, native, and post-contrast T1 maps were 134.1 ± 81.2, 133.7 ± 80.4, and 117.1 ± 53.3 mm², respectively. The median (interquartile range) MVO areas on LGE, native, and post-contrast T1 maps were 128.0 (58.1-215.4), 110.5 (67.7-227.9), and 143.0 (76.7-155.3) mm², respectively (p = 0.002). Concordance correlation coefficients for the MVO area between LGE and native T1 maps, LGE and post-contrast T1 maps, and native and post-contrast T1 maps were 0.770, 0.375, and 0.565, respectively.

CONCLUSION: MVO areas were accurately delineated on native T1 maps and showed high concordance with the areas measured on LGE. However, post-contrast T1 maps had low detection rates and underestimated MVO areas. Collectively, native T1 mapping is a useful tool for detecting MVO within the infarcted myocardium.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Shin JM, Choi EY, Park CH, et al. Quantitative T1 Mapping for Detecting Microvascular Obstruction in Reperfused Acute Myocardial Infarction: Comparison with Late Gadolinium Enhancement Imaging. Korean J Radiol. 2020. PMID: 32677382. doi:10.3348/kjr.2019.0736

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。