文献速递神经头颈外周血管CTDSA

颈动脉与脑血管双能量CT血管成像:虚拟单能成像重建窗设置的优化

Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction.
PubMed 文献 · Eur J Radiol · 2020-07-09

回顾性分析57例临床指征行颈动脉与脑血管第三代双源双能量CT血管成像的患者,比较线性融合(M_0.6)、70 keV传统虚拟单能(M70)和40 keV噪声优化虚拟单能(M40+)重建,由两名观察者独立确定主观最佳窗宽/窗位并与主动脉弓衰减关联计算优化值,另两名读者评估图像质量。M70和M40+的优化窗设置分别为560/200和1560/550,均高于标准双能量CT血管成像窗设置450/100;M40+在整体图像质量上主观评分最高(均p<0.001)。结论认为应用优化窗设置对于优化双能量CT血管成像虚拟单能重建的主观图像质量是必要的。

要点

  • 颈脑血管双能量CT血管成像虚拟单能重建的优化窗设置:M70为560/200,M40+为1560/550,均高于标准窗450/100。
  • 40 keV噪声优化虚拟单能(M40+)在整体图像质量上主观评分最高(均p<0.001)。
  • 应用优化窗设置对于优化双能量CT血管成像虚拟单能重建的主观图像质量是必要的。

核心结论

  • 应用优化窗设置对于优化双能量CT血管成像虚拟单能重建的主观图像质量是必要的。

研究设计与样本

  • 回顾性评估57例接受临床指征颈动脉与脑血管第三代双源双能量CT血管成像的患者。
  • 比较标准线性融合(M_0.6)、70 keV传统虚拟单能(M70)和40 keV噪声优化虚拟单能(M40+)重建。
  • 由两名观察者独立确定M70和M40+的主观最佳窗宽/窗位(B-W/L),并与主动脉弓衰减关联通过线性回归计算优化值(O-W/L)。
  • 由另外两名读者评估不同窗设置之间的图像质量主观评分。
  • 采用重复测量方差分析比较M_0.6、M70和M40+的窗设置和图像质量指标。

诊断标准与关键数值

  • M70的主观最佳窗宽/窗位为580/210,优化窗宽/窗位为560/200。
  • M40+的主观最佳窗宽/窗位为1630/570,优化窗宽/窗位为1560/550。
  • M70和M40+的窗设置均高于标准双能量CT血管成像窗设置450/100。
  • M40+在整体图像质量上主观评分最高(均p<0.001)。

临床应用与阅片要点

  • 颈脑血管双能量CT血管成像虚拟单能重建时,M70和M40+的窗设置应分别采用优化值560/200和1560/550,而非标准窗450/100。
  • M40+重建在整体图像质量上主观评分最高(均p<0.001),阅片时可优先关注该重建。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Dedicated post-processing of dual-energy computed tomography angiography (DE-CTA) datasets has been shown to allow for increased vascular contrast. The goal of our study was to define optimal window settings for displaying virtual monoenergetic images (VMI) reconstructed from dual-energy carotid and cerebrovascular DE-CTA.

METHODS: Fifty-seven patients who underwent clinically-indicated carotid and cerebrovascular third-generation dual-source DE-CTA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimized VMI (M40+) reconstructions were analyzed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with aortic arch attenuation to calculate optimized values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures analysis of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40 + .

RESULTS: B-W/L and O-W/L for M70 were 580/210 and 560/200, and for M40+ were 1630/570 and 1560/550, respectively, higher than standard DE-CTA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding overall IQ (all p < 0.001).

CONCLUSION: Application of O-W/L settings is mandatory to optimize subjective IQ of VMI reconstructions of DE-CTA.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. D'Angelo T, Lenga L, Arendt CT, et al. Carotid and cerebrovascular dual-energy computed tomography angiography: Optimization of window settings for virtual monoenergetic imaging reconstruction. Eur J Radiol. 2020. PMID: 32693314. doi:10.1016/j.ejrad.2020.109166

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。