文献速递妇产影像儿科影像心血管US

脉冲波多普勒测量胎儿心脏充盈时间分数与射血时间分数:参考范围及潜在临床应用

Fetal cardiac filling and ejection time fractions by pulsed-wave Doppler: reference ranges and potential clinical application.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-06-12

该研究纳入602例低危单胎妊娠与54例高危胎儿,用脉冲波多普勒测量左、右心室充盈时间分数(FTF)与射血时间分数(ETF),建立参考范围并评估可行性、可重复性及与心率、孕龄的关系;低危胎儿中FTF仅与心率相关,ETF取决于心率与孕龄,高危胎儿中重度TTTS受血儿多表现为FTF降低而ETF保留,主动脉瓣狭窄左心室FTF降低、ETF升高。

要点

  • 低危胎儿中约95%可获得合格FTF与ETF多普勒波形,观察者内ICC 0.831-0.905、观察者间ICC 0.801-0.837。
  • FTF仅与心率相关,心率降低时FTF升高;ETF取决于心率与孕龄,心率降低时ETF降低。
  • 重度TTTS受血儿多表现为FTF降低而ETF保留,主动脉瓣狭窄左心室FTF降低、ETF升高。

关键影像表现/征象

  • 低危胎儿中FTF随心率降低而升高,ETF则随心率降低而降低。
  • 重度TTTS受血儿多数表现为FTF降低而ETF保留。
  • 主动脉瓣狭窄胎儿左心室FTF降低、ETF升高,单心室与双心室产后结局似乎对应不同模式。
  • 主动脉缩窄胎儿多数双心室FTF与ETF均在正常范围内。

诊断标准与关键数值

  • 低危胎儿中约95%可获得合格FTF与ETF多普勒波形。
  • 观察者内可重复性良好至优秀,ICC 0.831-0.905;观察者间可重复性良好,ICC 0.801-0.837。
  • 多因素分析显示心率是低危胎儿FTF的唯一预测变量,ETF取决于心率与孕龄。

临床应用与阅片要点

  • 以瓣膜点击为标志测量左、右心室流入与流出道脉冲波多普勒信号,按(充盈时间/周期时间)×100与(射血时间/周期时间)×100计算FTF与ETF。
  • 判读FTF与ETF时应结合心率(FTF)及心率与孕龄(ETF),并使用低危人群构建的参考范围计算Z评分。
  • 在重度TTTS受血儿中注意FTF降低而ETF保留的模式;在主动脉瓣狭窄中注意左心室FTF降低、ETF升高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Fetal cardiac function can be evaluated using a variety of parameters. Among these, cardiac cycle time-related parameters, such as filling time fraction (FTF) and ejection time fraction (ETF), are promising but rarely studied. We aimed to report the feasibility and reproducibility of fetal FTF and ETF measurements using pulsed-wave Doppler, to provide reference ranges for fetal FTF and ETF, after evaluating their relationship with heart rate (HR), gestational age (GA) and estimated fetal weight (EFW), and to evaluate their potential clinical utility in selected fetal conditions.

METHODS: This study included a low-risk prospective cohort of singleton pregnancies and a high-risk population of fetuses with severe twin-twin transfusion syndrome (TTTS), aortic stenosis (AoS) or aortic coarctation (CoA), from 18 to 41 weeks' gestation. Left ventricular (LV) and right ventricular inflow and outflow pulsed-wave Doppler signals were analyzed, using valve clicks as landmarks. FTF was calculated as: (filling time/cycle time) × 100. ETF was calculated as: (ejection time/cycle time) × 100. Intraclass correlation coefficients (ICC) were used to evaluate the intra- and interobserver reproducibility of FTF and ETF measurements in low-risk fetuses. The relationships of FTF and ETF with HR, GA and EFW were evaluated using multivariate regression analysis. Reference ranges for FTF and ETF were then constructed using the low-risk population. Z-scores of FTF and ETF in the high-risk fetuses were calculated and analyzed.

RESULTS: In total, 602 low-risk singleton pregnancies and 54 high-risk fetuses (nine pairs of monochorionic twins with severe TTTS, 16 fetuses with AoS and 20 fetuses with CoA) were included. Adequate Doppler traces for FTF and ETF could be obtained in 95% of low-risk cases. Intraobserver reproducibility was good to excellent (ICC, 0.831-0.905) and interobserver reproducibility was good (ICC, 0.801-0.837) for measurements of all timing parameters analyzed. Multivariate analysis of FTF and ETF in relation to HR, GA and EFW in low-risk fetuses identified HR as the only variable predictive of FTF, while ETF was dependent on both HR and GA. FTF increased with decreasing HR in low-risk fetuses, while ETF showed the opposite behavior, decreasing with decreasing HR. Most recipient twins with severe TTTS showed reduced FTF and preserved ETF. AoS was associated with decreased FTF and increased ETF in the LV, with seemingly different patterns associated with univentricular vs biventricular postnatal outcome. The majority of fetuses with CoA had FTF and ETF within the normal range in both ventricles.

CONCLUSIONS: Measurement of FTF and ETF using pulsed-wave Doppler is feasible and reproducible in the fetus. The presented reference ranges account for associations of FTF with HR and of ETF with HR and GA. These time fractions are potentially useful for clinical monitoring of cardiac function in severe TTTS, AoS and other fetal conditions overloading the heart. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Soveral I, Crispi F, Guirado L, et al. Fetal cardiac filling and ejection time fractions by pulsed-wave Doppler: reference ranges and potential clinical application. Ultrasound Obstet Gynecol. 2021. PMID: 32672395. doi:10.1002/uog.22152

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。