文献速递心血管介入CT

全自动二尖瓣结构分析软件平台

A fully automated software platform for structural mitral valve analysis.
PubMed 文献 · Eur Radiol · 2020-07-02

研究纳入52例CCTA检查患者,评估全自动二尖瓣分析软件测量二尖瓣环参数与用户驱动软件的一致性。全自动测量与参考标准一致性良好至优秀,手动调整后一致性优秀,且分析时间显著缩短(134.4秒 vs 304.3秒)。

要点

  • 全自动二尖瓣分析软件联合手动调整与用户驱动软件一致性优秀(ICC 0.78–0.93)。
  • 全自动测量时间较标准评估显著缩短(134.4秒 vs 304.3秒,p<0.01)。
  • 全自动测量无需手动调整时一致性良好至优秀(ICC 0.62–0.81)。

核心结论

  • 全自动二尖瓣分析软件联合手动调整与用户驱动软件相关性很强,同时减少测量总时间。

研究设计与样本

  • 研究纳入52例(25例女性,平均年龄66.9±12.4岁)经CCTA评估拟行经导管二尖瓣置换或外科二尖瓣干预的患者;以用户驱动测量程序(3mensio,Pie Medical Imaging)为参考标准,比较全自动软件(有无手动调整)与参考标准的一致性(ICC),并分析测量时间。

诊断标准与关键数值

  • 全自动测量与用户驱动分析ICC:瓣环周长0.70、投影面积0.81、三角间距离0.64、前后径0.62、前外侧-后内侧径0.78;全自动测量联合手动调整与用户驱动分析ICC:周长0.91、投影面积0.93、三角间距离0.80、前后径0.78、前外侧-后内侧径0.79。

临床应用与阅片要点

  • 全自动二尖瓣分析软件联合手动调整可获得与用户驱动软件高度一致的二尖瓣环参数测量结果,并减少测量时间;未联合手动调整时一致性略低(ICC 0.62–0.81)。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate a novel fully automated mitral valve analysis software platform for cardiac computer tomography angiography (CCTA)-based structural heart therapy procedure planning.

METHODS: The study included 52 patients (25 women; mean age, 66.9 ± 12.4 years) who had undergone CCTA prior to transcatheter mitral valve replacement (TMVR) or surgical mitral valve intervention (replacement or repair). Therapeutically relevant mitral valve annulus parameters (projected area, circumference, trigone-to-trigone (T-T) distance, anterior-posterior (AP) diameter, and anterolateral-posteromedial (AL-PM) diameter) were measured. Results of the fully automated mitral valve analysis software platform with and without manual adjustments were compared with the reference standard of a user-driven measurement program (3mensio, Pie Medical Imaging). Measurements were compared between the fully automated software, both with and without manual adjustment, and the user-driven program using intraclass correlation coefficients (ICC). A secondary analysis included the time to obtain all measurements.

RESULTS: Fully automated measurements showed a good to excellent agreement (circumference, ICC = 0.70; projected area, ICC = 0.81; T-T distance, ICC = 0.64; AP, ICC = 0.62; and AL-PM diameter, ICC = 0.78) compared with the user-driven analysis. There was an excellent agreement between fully automated measurement with manual adjustments and user-driven analysis regarding circumference (ICC = 0.91), projected area (ICC = 0.93), T-T distance (ICC = 0.80), AP (ICC = 0.78), and AL-PM diameter (ICC = 0.79). The time required for mitral valve analysis was significantly lower using the fully automated software with manual adjustments compared with the standard assessment (134.4 ± 36.4 s vs. 304.3 ± 77.7 s) (p < 0.01).

CONCLUSION: The fully automated mitral valve analysis software, when combined with manual adjustments, demonstrated a strong correlation compared with the user-driven software while reducing the total time required for measurement.

KEY POINTS: • The novel software platform allows for a fully automated analysis of mitral valve structures. • An excellent agreement was found between the fully automated measurement with manual adjustments and the user-driven analysis. • The software showed quicker measurement time compared with the standard analysis of the mitral valve.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Steinbach R, Schoepf UJ, Griffith LP, et al. A fully automated software platform for structural mitral valve analysis. Eur Radiol. 2020. PMID: 32617689. doi:10.1007/s00330-020-06983-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。