基于深度学习的计算机辅助检测系统在疑似COVID-19患者胸部X线判读中的实施
单中心回顾性研究评估深度学习CAD辅助放射科医生判读疑似COVID-19患者胸片的表现,以rRT-PCR和胸部CT肺炎为参考标准。332例中16例(4.8%)COVID-19阳性,CAD辅助判读敏感度68.8%、特异度66.7%;119例有CT者中肺炎判读敏感度81.5%、特异度72.3%。胸片报告周转时间中位51分钟,显著短于rRT-PCR的507分钟(p<0.001)。
要点
- CAD辅助判读胸片诊断COVID-19的敏感度68.8%、特异度66.7%。
- CAD辅助判读胸片报告肺炎的敏感度81.5%、特异度72.3%。
- 胸片报告周转时间中位51分钟,显著短于rRT-PCR的507分钟。
核心结论
- CAD辅助放射科医生判读胸片可识别rRT-PCR阳性COVID-19或肺炎患者,表现可接受。
- 疑似COVID-19患者中,胸片周转时间远快于rRT-PCR。
研究设计与样本
- 单中心回顾性研究,纳入疑似或确诊COVID-19患者的初始胸片。
- 采用商业化深度学习CAD系统在日常实践中辅助判读胸片。
- 以rRT-PCR结果和胸部CT提示肺炎的肺部异常为两种参考标准评估诊断性能。
诊断标准与关键数值
- 332例有rRT-PCR结果患者中16例(4.8%)诊断为COVID-19,CAD辅助判读胸片敏感度68.8%、特异度66.7%。
- 119例有胸部CT患者中,CAD辅助判读胸片报告肺炎敏感度81.5%、特异度72.3%。
临床应用与阅片要点
- CAD辅助判读胸片可用于疑似COVID-19患者的日常判读,周转时间中位51分钟。
- 胸片报告周转时间显著短于rRT-PCR结果(中位51 vs. 507分钟,p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To describe the experience of implementing a deep learning-based computer-aided detection (CAD) system for the interpretation of chest X-ray radiographs (CXR) of suspected coronavirus disease (COVID-19) patients and investigate the diagnostic performance of CXR interpretation with CAD assistance.
MATERIALS AND METHODS: In this single-center retrospective study, initial CXR of patients with suspected or confirmed COVID-19 were investigated. A commercialized deep learning-based CAD system that can identify various abnormalities on CXR was implemented for the interpretation of CXR in daily practice. The diagnostic performance of radiologists with CAD assistance were evaluated based on two different reference standards: 1) real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) results for COVID-19 and 2) pulmonary abnormality suggesting pneumonia on chest CT. The turnaround times (TATs) of radiology reports for CXR and rRT-PCR results were also evaluated.
RESULTS: Among 332 patients (male:female, 173:159; mean age, 57 years) with available rRT-PCR results, 16 patients (4.8%) were diagnosed with COVID-19. Using CXR, radiologists with CAD assistance identified rRT-PCR positive COVID-19 patients with sensitivity and specificity of 68.8% and 66.7%, respectively. Among 119 patients (male:female, 75:44; mean age, 69 years) with available chest CTs, radiologists assisted by CAD reported pneumonia on CXR with a sensitivity of 81.5% and a specificity of 72.3%. The TATs of CXR reports were significantly shorter than those of rRT-PCR results (median 51 vs. 507 minutes; p < 0.001).
CONCLUSION: Radiologists with CAD assistance could identify patients with rRT-PCR-positive COVID-19 or pneumonia on CXR with a reasonably acceptable performance. In patients suspected with COVID-19, CXR had much faster TATs than rRT-PCRs.
引用
- Hwang EJ, Kim H, Yoon SH, et al. Implementation of a Deep Learning-Based Computer-Aided Detection System for the Interpretation of Chest Radiographs in Patients Suspected for COVID-19. Korean J Radiol. 2020. PMID: 32729263. doi:10.3348/kjr.2020.0536