低碘低辐射剂量主动脉CT血管成像中四种对比剂注射方案的比较
在70 kVp和200 mg碘/kg条件下对205例患者行双低CT血管成像,比较四种对比剂注射方案并与常规组对照,结果显示辐射剂量降低62%、碘剂量降低50%,低浓度方案主动脉强化最稳定一致而被推荐,慢速方案可作为静脉条件受限时的备选。
要点
- 双低方案(70 kVp、200 mg碘/kg)较常规方案辐射剂量降低62%、碘剂量降低50%。
- 短时程组峰值强化最高但均匀性最差、主观评分最低。
- 低浓度方案强化良好且均匀性佳(78%和96.0%),主动脉强化最稳定一致。
关键影像表现/征象
- 四个双低组间胸主动脉信噪比和对比噪声比相似,但腹主动脉存在显著差异。
- 短时程组峰值强化最高、均匀性最差、主观评分最低。
- 慢速组强化良好和均匀性良好的比例分别为86.6%和90.4%,低浓度组分别为78%和96.0%。
- 主观评分呈现低浓度组偏高、慢速组偏低的趋势(p=0.071)。
诊断标准与关键数值
- 双低方案参数为70 kVp、200 mg碘/kg,常规方案为120 kVp、400 mg碘/kg。
- 双低四组整体辐射剂量降低62%,碘剂量降低50%。
- 短时程组峰值强化最高,但均匀性最差、主观评分最低。
- 慢速组强化良好与均匀性良好比例分别为86.6%和90.4%,低浓度组分别为78%和96.0%。
- 主观评分组间比较p=0.071,未达统计学显著。
临床应用与阅片要点
- 作者推荐低浓度方案,因其主动脉强化表现最稳定一致。
- 作者认为慢速方案可考虑用于静脉通路受限的患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate contrast medium delivery protocols for the optimal enhancement profile of the aorta with both a reduced dose of radiation and contrast medium, called double-low computed tomography (CT) angiography (DLCTA).
MATERIALS AND METHODS: DLCTA was performed with 70 kVp and 200 mg iodine/kg in 205 patients following four protocols, namely slow rate (n=52), short duration (n=52), low concentration (n=50), and combined method (n=51), in comparison with a conventional group (120 kVp, 400 mg iodine/kg, n=51). The quantitative measurement of aortic attenuation, homogeneity, and subjective scores were evaluated.
RESULTS: Overall, in the four DLCTA groups, the radiation dose was reduced by 62%, and the iodine dose was reduced by 50%. Among the four DLCTA groups, the signal to noise ratio (SNR) and contrast to noise ratio (CNR) of the thoracic aorta were similar, but a significant difference was noted in the abdominal aorta. The short-duration group had the highest peak enhancement, least homogeneity, and worst subjective scores. Good contrast enhancement and good homogeneity were significantly more frequent in the slow-rate (86.6% and 90.4%, respectively) and low-concentration groups (78% and 96.0%, respectively). Subjective scores exhibited a trend of higher scores in the low-concentration group and lower scores in the slow-rate group (p=0.071).
CONCLUSION: DLCTA with 70 kVp and 200 mg iodine/kg is feasible for whole-aortic CT angiography. The low-concentration protocol is recommended owing to its most consistent optimal aortic enhancement profile. Alternatively, the slow-rate protocol can be considered for patients with limited venous access.
引用
- Chen PA, Huang EP, Chen KT, et al. Comparison of four contrast medium delivery protocols in low-iodine and low-radiation dose CT angiography of the aorta. Clin Radiol. 2020. PMID: 32703542. doi:10.1016/j.crad.2020.06.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。