文献速递心血管外周血管MR

使用卷积神经网络快速重建胸主动脉四维MR血管造影

Rapid Reconstruction of Four-dimensional MR Angiography of the Thoracic Aorta Using a Convolutional Neural Network.
PubMed 文献 · Radiol Cardiothorac Imaging · 2020-06-25

本研究纳入24例疑似胸主动脉疾病患者的原始k空间数据,评估基于GPU的卷积神经网络重建流程,并与CPU压缩感知重建比较。CNN重建时间较压缩感知缩短约65–69倍(P < .001),结构相似指数0.94±0.02、归一化均方根误差2.8%±0.4, summed视觉评分及主动脉直径无显著差异(P = .25),仅7个位置中1处直径差异为3%。

要点

  • CNN重建时间较压缩感知缩短约65–69倍(P < .001),数据保真度高(SSIM=0.94±0.02)。
  • CNN与压缩感知的summed视觉评分及主动脉直径无显著差异(P = .25)。
  • 仅7个测量位置中1处主动脉直径差异为3%,原文认为无临床相关性。

诊断标准与关键数值

  • 以压缩感知重建作为实际参考标准,CNN重建的结构相似指数为0.94±0.02,归一化均方根误差为2.8%±0.4。
  • CNN与压缩感知的summed视觉评分无显著差异(P = .25),评分标准为3=不可诊断、9=临床可接受、15=优秀。
  • CNN与压缩感知的主动脉直径无显著差异(P = .25),仅7个位置中1处直径百分比差异为3%。

临床应用与阅片要点

  • CNN重建时间较压缩感知缩短约65–69倍(CPU-CNN 216.6秒±40.5 vs 压缩感知14 152.3秒±1708.6;GPU-CNN 204.9秒±40.5 vs 压缩感知14 152.3秒±1708.6),可能支持快速重建非增强四维MR血管造影。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To implement an integrated reconstruction pipeline including a graphics processing unit (GPU)-based convolutional neural network (CNN) architecture and test whether it reconstructs four-dimensional non-Cartesian, non-contrast material-enhanced MR angiographic k-space data faster than a central processing unit (CPU)-based compressed sensing (CS) reconstruction pipeline, without significant losses in data fidelity, summed visual score (SVS), or arterial vessel-diameter measurements.

MATERIALS AND METHODS: Raw k-space data of 24 patients (18 men and six women; mean age, 56.8 years ± 11.8 [standard deviation]) suspected of having thoracic aortic disease were used to evaluate the proposed reconstruction pipeline derived from an open-source three-dimensional CNN. For training, 4800 zero-filled images and the corresponding CS-reconstructed images from 10 patients were used as input-output pairs. For testing, 6720 zero-filled images from 14 different patients were used as inputs to a trained CNN. Metrics for evaluating the agreement between the CNN and CS images included reconstruction times, structural similarity index (SSIM) and normalized root-mean-square error (NRMSE), SVS (3 = nondiagnostic, 9 = clinically acceptable, 15 = excellent), and vessel diameters.

RESULTS: The mean reconstruction time was 65 times and 69 times shorter for the CPU-based and GPU-based CNN pipelines (216.6 seconds ± 40.5 and 204.9 seconds ± 40.5), respectively, than for CS (14 152.3 seconds ± 1708.6) (P < .001). Compared with CS as practical ground truth, CNNs produced high data fidelity (SSIM = 0.94 ± 0.02, NRMSE = 2.8% ± 0.4) and not significantly different (P = .25) SVS and aortic diameters, except at one out of seven locations, where the percentage difference was only 3% (ie, clinically irrelevant).

CONCLUSION: The proposed integrated reconstruction pipeline including a CNN architecture is capable of rapidly reconstructing time-resolved volumetric cardiovascular MRI k-space data, without a significant loss in data quality, thereby supporting clinical translation of said non-contrast-enhanced MR angiograms. Supplemental material is available for this article. © RSNA, 2020.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Haji-Valizadeh H, Shen D, Avery RJ, et al. Rapid Reconstruction of Four-dimensional MR Angiography of the Thoracic Aorta Using a Convolutional Neural Network. Radiol Cardiothorac Imaging. 2020. PMID: 32656535. doi:10.1148/ryct.2020190205

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。