双能CT碘定量与常规CT在急性肺栓塞中的预后价值:倾向性匹配分析
本研究纳入480例急性肺栓塞患者,倾向性匹配后常规CT肺动脉造影(CTPA)组与双能CT肺动脉造影(DE CT-PA)组各240例,比较CT参数对30天内全因死亡的预测价值。两组中右/左心室直径比≥1均与30天内全因死亡风险升高相关,但双能CT定量测量肺灌注缺损体积较CT心室直径比无额外预测获益(C统计量0.759 vs 0.819,p=0.117)。
要点
- 右/左心室直径比≥1在CTPA组和DECT组均与30天内全因死亡风险升高相关。
- 双能CT肺灌注缺损体积定量对30天全因死亡的预测较CT心室直径比无额外获益。
- CTPA组与DECT组预测30天死亡的C统计量差异无统计学意义(0.759 vs 0.819,p=0.117)。
核心结论
- 双能CT定量测量肺灌注缺损体积对预测30天内全因死亡较CT心室直径比无额外获益。
研究设计与样本
- 本研究为倾向性匹配分析,纳入480例急性肺栓塞患者,其中CTPA组与DECT组各240例。
- 260例(54.1%)为男性,平均年龄64.9岁(64.9 ± 13.5岁)。
- 主要终点为30天内全因死亡,采用Cox比例风险回归模型分析CT参数与结局的关联,用一致性(C)统计量比较两组预后预测能力。
关键影像表现/征象
- CTPA组中右/左心室直径比≥1与30天内全因死亡风险升高相关(风险比3.707,p < 0.001)。
- DECT组中右/左心室直径比≥1与30天内全因死亡风险升高相关(风险比5.573,p < 0.001)。
诊断标准与关键数值
- 右/左心室直径比≥1在CTPA组预测30天内全因死亡的风险比为3.707(p < 0.001)。
- 右/左心室直径比≥1在DECT组预测30天内全因死亡的风险比为5.573(p < 0.001)。
- CTPA组与DECT组预测30天内死亡的C统计量分别为0.759与0.819,差异无统计学意义(p = 0.117)。
临床应用与阅片要点
- 原文结论未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The present study aimed to investigate whether quantitative dual-energy computed tomography (DECT) parameters offer an incremental risk stratification benefit over the CT ventricular diameter ratio in patients with acute pulmonary embolism (PE) by using propensity score analysis.
MATERIALS AND METHODS: This study was conducted on 480 patients with acute PE who underwent CT pulmonary angiography (CTPA) or DECT pulmonary angiography (DE CT-PA). This propensity-matched study population included 240 patients with acute PE each in the CTPA and DECT groups. Altogether, 260 (54.1%) patients were men, and the mean age was 64.9 years (64.9 ± 13.5 years). The primary endpoint was all-cause death within 30 days. The Cox proportional hazards regression model was used to identify associations between CT parameters and outcomes and to identify potential predictors. Concordance (C) statistics were used to compare the prognoses between the two groups.
RESULTS: In both CTPA and DECT groups, right to left ventricle diameter ratio ≥ 1 was associated with an increased risk of all-cause death within 30 days (hazard ratio: 3.707, p < 0.001 and 5.573, p < 0.001, respectively). However, C-statistics showed no statistically significant difference between the CTPA and DECT groups for predicting death within 30 days (C-statistics: 0.759 vs. 0.819, p = 0.117).
CONCLUSION: Quantitative measurement of lung perfusion defect volume by DECT had no added benefit over CT ventricular diameter ratio for predicting all-cause death within 30 days.
引用
- Im DJ, Hur J, Han K, et al. Prognostic Value of Dual-Energy CT-Based Iodine Quantification versus Conventional CT in Acute Pulmonary Embolism: A Propensity-Match Analysis. Korean J Radiol. 2020. PMID: 32691545. doi:10.3348/kjr.2019.0645
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。