肺移植受者的定量多容积质子磁共振成像:与计算机断层扫描和肺量计检查的比较
本研究纳入10例肺移植受者,在1.5T MRI和CT下于完全呼气末和完全吸气末屏气采集,计算MR信号强度和CT密度的呼气-吸气差值图以评估区域通气,并按健康、低通气、空气潴留和实变四类量化各像素体积百分比。结果显示MR信号强度呼气-吸气差值与CT密度(r=0.64,p<0.0001)及FEV1(ρ=0.71,p=0.02)相关,MRI与CT功能图四类总线性相关r=0.93(p<0.0001),MRI空气潴留百分比与FEV1 %pred相关性最高(ρ=-0.82)。作者认为定量MRI可能作为肺移植受者纵向监测的无电离辐射成像技术。
要点
- MRI与CT功能图在健康、低通气、空气潴留和实变四类总线性相关r=0.93(p<0.0001)。
- MR信号强度呼气-吸气差值与CT密度相关r=0.64(p<0.0001),与FEV1相关ρ=0.71(p=0.02)。
- MRI空气潴留百分比与FEV1 %pred相关性最高(ρ=-0.82)。
核心结论
- MRI与CT通气成像及对应肺损伤体积百分比之间显示出良好一致性。
- 定量MRI可能代表一种用于肺移植受者纵向监测的准确无电离辐射成像技术。
研究设计与样本
- 研究纳入10例肺移植受者(39±12岁,FEV1=81±27%,FVC=87±27%),在1.5T MRI和CT下于完全呼气末和完全吸气末屏气采集。
- 计算MR信号强度和CT密度的呼气-吸气差值图以估计区域通气。
- 根据呼气、吸气及呼气-吸气差值将每个像素分类为健康(H)、低通气(LV)、空气潴留(AT)和实变(C),并量化各类百分比范围。
关键影像表现/征象
- MR信号强度呼气-吸气差值与CT密度相关(r=0.64,p<0.0001),与FEV1相关(ρ=0.71,p=0.02)。
- 考虑全部四类时,MRI与CT功能图的线性相关r=0.93(p<0.0001)。
- MRI健康、空气潴留和实变百分比与FEV1 %pred相关,其中空气潴留相关性最高(ρ=-0.82)。
诊断标准与关键数值
- 基于呼气、吸气及呼气-吸气差值将像素分类为健康(H)、低通气(LV)、空气潴留(AT)和实变(C),并量化各类百分比范围。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Acute and chronic graft rejection remains the major problem in clinical surveillance of lung-transplanted patients and early detection of complications is of capital importance to allow the optimal therapeutic option. The aim of this study was to investigate the role of quantitative non contrast-enhanced magnetic resonance imaging (MRI) as a non-ionizing imaging modality to assess ventilation impairment in patients who have undergone lung transplantation, in comparison with quantitative computed tomography (CT) and spirometry.
MATERIALS AND METHODS: Ten lung-transplanted patients (39 ±12 years, forced-expiratory volume in 1 second (FEV1) = 81 ± 27%, forced vital capacity (FVC) = 87 ± 27%) were acquired in breath-hold at full-expiration and full-inspiration with 1.5T MRI and CT. Maps of expiratory-inspiratory difference in MR signal-intensity and CT-density were computed to estimate regional ventilation. Based on expiratory, inspiratory, and expiratory-inspiratory difference values, each pixel was classified as healthy (H), low ventilation (LV), air trapping (AT), and consolidation (C) and the percent extent of each class was quantified.
RESULTS: Overall, expiratory-inspiratory difference in MR signal-intensity correlated to CT-density (r = 0.64, p < 0.0001) and to FEV1 (ρ = 0.71, p = 0.02). The linear correlation between MRI and CT functional maps considering all the four classes is r = 0.93 (p < 0.0001). MRI percent volumes of H, AT, and C correlated to FEV1 %pred, with the highest correlation reported for AT (ρ = -0.82).
CONCLUSION: Results demonstrated a good agreement between MRI and CT ventilation imaging and between the corresponding percent volumes of lung damage. Quantitative MRI may represent an accurate non-ionizing imaging technique for longitudinal monitoring of lung transplant recipients.
引用
- Pennati F, Salito C, Borzani I, et al. Quantitative Multivolume Proton-Magnetic Resonance Imaging in Lung Transplant Recipients: Comparison With Computed Tomography and Spirometry. Acad Radiol. 2020. PMID: 32653430. doi:10.1016/j.acra.2020.05.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。