文献速递胸部CT

使用深度学习基核转换的低剂量计算机断层扫描进行肺气肿定量比较

Emphysema quantification using low-dose computed tomography with deep learning-based kernel conversion comparison.
PubMed 文献 · Eur Radiol · 2020-06-29

研究纳入131名参与者,比较低剂量CT与标准剂量CT在不同重建核下定量肺气肿的差异,并评估深度学习核转换技术。结果显示锐利核B50f显著高估肺气肿,深度学习转换后变异减小,在非COPD参与者中与标准剂量CT无显著差异。

要点

  • 低剂量CT平滑核B31f定量肺气肿与标准剂量CT B30f性能相当。
  • 锐利核B50f会导致肺气肿定量显著高估。
  • 深度学习核转换可显著减少锐利核定量肺气肿的变异。

核心结论

  • 基于深度学习的CT核转换将低剂量CT锐利核转换为平滑核后显著减少肺气肿定量变异,可用于肺气肿定量。

研究设计与样本

  • 131名参与者间隔1至2年接受低剂量CT和标准剂量CT;低剂量CT重建B31f和B50f核,标准剂量CT重建B30f核;使用深度学习模型将低剂量CT B50f转换为B31f;计算肺气肿指数、第15百分位肺衰减和平均肺密度。

诊断标准与关键数值

  • 低剂量CT B50f的所有值均与低剂量CT B31f和标准剂量CT B30f有显著差异(p<0.05);核归一化后低剂量CT B50f的变异显著减小;标准剂量CT与低剂量CT B31f的95%一致性界限为-2.9%至4.3%,与转换后B50f为-3.2%至4.4%;在非COPD参与者中,标准剂量CT与低剂量CT转换后B50f的肺气肿指数和第15百分位肺衰减无显著差异(p>0.05)。

临床应用与阅片要点

  • 阅读低剂量CT肺气肿定量时需注意重建核选择,锐利核B50f会显著高估肺气肿;深度学习核转换可减少变异,在非COPD参与者中转换后B50f与标准剂量CT结果无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study determined the effect of dose reduction and kernel selection on quantifying emphysema using low-dose computed tomography (LDCT) and evaluated the efficiency of a deep learning-based kernel conversion technique in normalizing kernels for emphysema quantification.

METHODS: A sample of 131 participants underwent LDCT and standard-dose computed tomography (SDCT) at 1- to 2-year intervals. LDCT images were reconstructed with B31f and B50f kernels, and SDCT images were reconstructed with B30f kernels. A deep learning model was used to convert the LDCT image from a B50f kernel to a B31f kernel. Emphysema indices (EIs), lung attenuation at 15th percentile (perc15), and mean lung density (MLD) were calculated. Comparisons among the different kernel types for both LDCT and SDCT were performed using Friedman's test and Bland-Altman plots.

RESULTS: All values of LDCT B50f were significantly different compared with the values of LDCT B31f and SDCT B30f (p < 0.05). Although there was a statistical difference, the variation of the values of LDCT B50f significantly decreased after kernel normalization. The 95% limits of agreement between the SDCT and LDCT kernels (B31f and converted B50f) ranged from - 2.9 to 4.3% and from - 3.2 to 4.4%, respectively. However, there were no significant differences in EIs and perc15 between SDCT and LDCT converted B50f in the non-chronic obstructive pulmonary disease (COPD) participants (p > 0.05).

CONCLUSION: The deep learning-based CT kernel conversion of sharp kernel in LDCT significantly reduced variation in emphysema quantification, and could be used for emphysema quantification.

KEY POINTS: • Low-dose computed tomography with smooth kernel showed adequate performance in quantifying emphysema compared with standard-dose CT. • Emphysema quantification is affected by kernel selection and the application of a sharp kernel resulted in a significant overestimation of emphysema. • Deep learning-based kernel normalization of sharp kernel significantly reduced variation in emphysema quantification.