文献速递胸部CT

胸部X线剂量等效CT中的肺炎检测:剂量降低对人工智能可检测性的影响

Pneumonia Detection in Chest X-Ray Dose-Equivalent CT: Impact of Dose Reduction on Detectability by Artificial Intelligence.
PubMed 文献 · Acad Radiol · 2020-07-01

这项回顾性研究纳入100例疑似肺部感染或已知肺结节随访患者,每例均接受标准剂量(1.43 ± 0.54 mSv)和剂量降低20倍(0.07 ± 0.03 mSv)的CT扫描,训练深度神经网络进行二分类(有无肺实变)。标准剂量CT的AUC为0.923(95%CI 0.905-0.941),显著高于降低剂量CT的AUC 0.881(95%CI 0.859-0.903)(p = 0.001);敏感度分别为82.9%和71.0%,特异度分别为93.8%和93.3%。结论认为X线剂量等效CT用人工智能检测肺炎可行,剂量降低会降低深度神经网络性能,使用AI算法时需优化和调整CT协议。

要点

  • 标准剂量CT的AUC为0.923,降低剂量CT的AUC为0.881,两者差异有统计学意义(p = 0.001)。
  • 标准剂量CT敏感度82.9%、特异度93.8%;降低剂量CT敏感度71.0%、特异度93.3%。
  • 剂量降低20倍(0.07 ± 0.03 mSv vs 1.43 ± 0.54 mSv)时AI检测肺炎性能下降。

核心结论

  • 使用人工智能在X线剂量等效CT上检测肺炎是可行的,可能有助于获得更稳健和可重复的诊断性能;剂量降低降低了深度神经网络的性能,提示使用AI算法在降低剂量时需优化和调整CT协议。

研究设计与样本

  • 回顾性研究,纳入100例因疑似肺部感染和/或已知肺结节随访转诊至本科室的患者,每例均接受标准剂量(1.43 ± 0.54 mSv)和剂量降低20倍(0.07 ± 0.03 mSv)的CT扫描,训练深度神经网络进行二分类(有无肺实变),并在标准剂量和降低剂量CT图像上评估诊断性能。

诊断标准与关键数值

  • 深度神经网络二分类任务为肺实变存在与否;标准剂量CT的AUC为0.923(95%CI 0.905-0.941),降低剂量CT的AUC为0.881(95%CI 0.859-0.903),差异p = 0.001;标准剂量CT敏感度82.9%、特异度93.8%,降低剂量CT敏感度71.0%、特异度93.3%。

临床应用与阅片要点

  • 作者认为X线剂量等效CT使用人工智能检测肺炎可行,可能有助于更稳健和可重复的诊断性能;剂量降低会降低深度神经网络性能,作者提出使用AI算法在降低剂量时需优化和调整CT协议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: There has been a significant increase of immunocompromised patients in recent years due to new treatment modalities for previously fatal diseases. This comes at the cost of an elevated risk for infectious diseases, most notably pathogens affecting the respiratory tract. Because early diagnosis and treatment of pneumonia can help reducing morbidity and mortality, we assessed the performance of a deep neural network in the detection of pulmonary infection in chest X-ray dose-equivalent computed tomography (CT).

MATERIALS AND METHODS: The 100 patients included in this retrospective study were referred to our department for suspicion of pulmonary infection and/or follow-up of known pulmonary nodules. Every patient was scanned with a standard dose (1.43 ± 0.54 mSv) and a 20 times dose-reduced (0.07 ± 0.03 mSv) CT protocol. We trained a deep neural network to perform binary classification (pulmonary consolidation present or not) and assessed diagnostic performance on both standard dose and reduced dose CT images.

RESULTS: The areas under the curve of the deep learning algorithm for the standard dose CT was 0.923 (confidence interval [CI] 95%: 0.905-0.941) and significantly higher than the areas under the curve (0.881, CI 95%: 0.859-0.903) of the reduced dose CT (p = 0.001). Sensitivity and specificity of the standard dose CT was 82.9% and 93.8%, and of the reduced dose CT 71.0% and 93.3%.

CONCLUSION: Pneumonia detection with X-ray dose-equivalent CT using artificial intelligence is feasible and may contribute to a more robust and reproducible diagnostic performance. Dose reduction lowered the performance of the deep neural network, which calls for optimization and adaption of CT protocols when using AI algorithms at reduced doses.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Schwyzer M, Martini K, Skawran S, et al. Pneumonia Detection in Chest X-Ray Dose-Equivalent CT: Impact of Dose Reduction on Detectability by Artificial Intelligence. Acad Radiol. 2020. PMID: 32622747. doi:10.1016/j.acra.2020.05.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。