文献速递胸部技术与安全CT

COVID-19对法国放射中心影响的评估:一项全国性调查

COVID-19 impact assessment on the French radiological centers: a nationwide survey.
PubMed 文献 · Eur Radiol · 2020-07-03

该前瞻性横断面在线调查于2020年3月16日至4月12日每周收集法国709家受邀放射中心的CT活动数据,最终577家注册(78%)。胸部CT活动量随周次变化,COVID-19相关CT占胸部CT比值从0.36至0.59,且与RT-PCR检测数量显著相关(r=0.73,p=3.10-16)。结论为局部高密度COVID-19时CT工作流程被强烈改变并转向该类患者管理。

要点

  • 4周调查期内响应中心共完成117,686例胸部CT,其中61,784例(52%)为COVID-19相关CT。
  • 全国CTcovid/CTtotal比值从0.36至0.59,显著依赖局部疫情密度(p=0.003)。
  • RT-PCR检测数量与COVID-19相关CT数量显著相关(r=0.73,p=3.10-16),但与阳性RT-PCR结果数量无关联。

核心结论

  • 局部高密度COVID-19时,CT工作流程被强烈改变并转向该类特定患者的管理。

研究设计与样本

  • 前瞻性横断面CT扫描调查,于2020年3月16日至4月12日按当地IRB进行,邀请709家放射中心每周在线参与,最终577家注册(78%),平均响应数为336±18.9(323;351)。

关键影像表现/征象

  • 每周记录至少包含胸部的COVID-19相关CT检查数(CTcovid)和全胸CT扫描活动数(CTchest)。
  • 每放射中心平均CTchest活动量从第12周75.8±133(0-1444)至第13周99.3±138.6(0-1147)。
  • CTcovid占CTchest平均比值在第12周至第14周分别为0.36至0.59。

临床应用与阅片要点

  • 在法国疫情增长背景下,胸部CT在临床实践中被用作RT-PCR的替代方法用于患者分诊。
  • 全国CTcovid/CTtotal比值从0.36至0.59,显著依赖局部疫情密度(p=0.003)。
  • RT-PCR检测数量与COVID-19相关CT数量显著相关(r=0.73,p=3.10-16),但与阳性RT-PCR结果数量无关联。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the impact of the COVID-19 on the CT activities in French radiological centers during the epidemic peak.

MATERIALS AND METHODS: A cross-sectional prospective CT scan survey was conducted between March 16 and April 12, 2020, in accordance with the local IRB. Seven hundred nine radiology centers were invited to participate in a weekly online survey. Numbers of CT examinations related to COVID-19 including at least chest (CTcovid) and whole chest CT scan activities (CTchest) were recorded each week. A sub-analysis on French departments was performed during the 4 weeks of the study. The impact of the number of RT-PCRs (reverse transcriptase polymerase chain reactions) on the CT workflow was tested using two-sample t test and Pearson's test.

RESULTS: Five hundred seventy-seven structures finally registered (78%) with mean response numbers of 336 ± 18.9 (323; 351). Mean CTchest activity per radiologic structure ranged from 75.8 ± 133 (0-1444) on week 12 to 99.3 ± 138.6 (0-1147) on week 13. Mean ratio of CTcovid on CTchest varied from 0.36 to 0.59 on week 12 and week 14 respectively. There was a significant relationship between the number of RT-PCR performed and the number of CTcovid (r = 0.73, p = 3.10-16) but no link with the number of positive RT-PCR results.

CONCLUSION: In case of local high density COVID-19, CT workflow is strongly modified and redirected to the management of these specific patients.

KEY POINTS: • Over the 4-week survey period, 117,686 chest CT (CTtotal) were performed among the responding centers, including 61,784 (52%) CT performed for COVID-19 (CTcovid). • Across the country, the ratio CTcovid/CTtotal varied from 0.36 to 0.59 and depended significantly on the local epidemic density (p = 0.003). • In clinical practice, in a context of growing epidemic, in France, chest CT was used as a surrogate to RT-PCR for patient triage.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Herpe G, Naudin M, Léderlin M, et al. COVID-19 impact assessment on the French radiological centers: a nationwide survey. Eur Radiol. 2020. PMID: 32621241. doi:10.1007/s00330-020-07035-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。