文献速递心血管胸部CT

非心电门控胸部CT用于心脏评估的表现:胸部CT心脏病理(CaPaCT)研究

The performance of non-ECG gated chest CT for cardiac assessment - The cardiac pathologies in chest CT (CaPaCT) study.
PubMed 文献 · Eur J Radiol · 2020-06-25

该研究纳入2016年5月至2018年3月连续215例非心电门控胸部CT患者,评估冠状动脉钙化检出率、图像质量及CAD-RADS分类预测心血管事件的临床性能。结果显示72.6%患者存在钙化,其中43.6%图像质量达充分-极好,CAD-RADS≥3者占57.4%,随访中仅CAD-RADS≥3患者发生心血管事件,提示CAD-RADS可能有助于识别未来心血管事件风险患者。

要点

  • 非心电门控胸部CT可检出冠状动脉钙化,本组检出率72.6%。
  • 仅43.6%钙化患者图像质量达充分-极好,可进一步行CAD-RADS分析。
  • CAD-RADS≥3患者中随访期间18%发生心血管事件,CAD-RADS<3者未发生。

核心结论

  • 非心电门控胸部CT检出冠状动脉钙化者占72.6%,其中近半数可行心脏评估。
  • 仅CAD-RADS≥3的患者发生心血管事件,CAD-RADS可能有助于识别和指导未来心血管事件风险患者。

研究设计与样本

  • 研究纳入2016年5月至2018年3月连续215例转诊行胸部CT的患者,采用第三代双源CT非心电门控采集。
  • 扫描参数包括自动管电压选择(110kVqual.ref/40mAsqual.ref)、螺距2.65-3.0及个体化对比剂注射方案。
  • 在标准胸部重建基础上增加专用心脏后处理重建(0.6 mm/0.4 mm/卷积核Bv36)。
  • 由两名独立心脏放射科医师进行三步分析,意见不一致时由第三名医师最终判定。
  • 通过电子病历核查病变是否既往已知(偶然发现)及随访期间是否发生心血管事件。

关键影像表现/征象

  • 215例中156例(72.6%)存在冠状动脉钙化,其中74例为偶然发现。
  • 156例钙化患者中68例(43.6%)图像质量评为充分-极好。
  • 68例可评估患者中39例(57.4%)CAD-RADS≥3,其中12例(30.8%)为偶然发现。

诊断标准与关键数值

  • 图像质量采用5点Likert量表评估(差/充分/中等/好/极好)。
  • 仅在Likert评分为充分-极好时使用CAD-RADS进行狭窄严重程度分析。
  • CAD-RADS≥3在可评估的68例中占39例(57.4%)。

临床应用与阅片要点

  • 非心电门控胸部CT上可视觉判断冠状动脉钙化,本组检出率72.6%。
  • 对图像质量达充分-极好的钙化患者可进一步行CAD-RADS分类评估狭窄。
  • CAD-RADS≥3患者中随访期间18%(7/39)发生心血管事件,CAD-RADS<3者未发生。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Evaluating the prevalence of CAD on non-ECG gated chest CTs, image quality (IQ) and the clinical performance of the CAD-RADS classification for predicting cardiovascular events (CVE).

METHODS: 215 consecutive patients referred for chest CTs between May 2016 and March 2018 were included (3rd-generation DSCT) using non-ECG gated acquisitions with automated tube voltage selection (110kVqual.ref/40mAsqual.ref), pitch 2.65-3.0 and individualized contrast media injection protocols. Dedicated cardiac post-processing reconstructions (0.6 mm/0.4 mm/Kernel Bv36) were added to standard chest reconstructions. Two independent cardiac radiologists performed a 3-step analysis. In case of discrepancy, a third reader gave the final decision. Step 1: visual presence of calcifications; 2: scans with calcifications assessed for IQ using a 5-point Likert scale (poor/sufficient/moderate/good/excellent); 3: stenosis severity was analysed in detail (if Likert sufficient-excellent using CAD-RADS). Electronic patient files were checked to see if pathology was previously mentioned (incidental) and whether patients developed an CVE during follow-up.

RESULTS: 1: Calcifications were present in 156/215 cases (72.6 %), 74 of these were incidental. 2: In 68/156 (43.6 %) patients with calcifications IQ was rated sufficient-excellent. 3: CAD-RADS≥3 was seen in 39/68 patients (57.4 %), 12 times (30.8 %) findings were incidental. During follow-up (median 16 [0-35] months), 7/39 (18 %) patients with CAD-RADS≥3 developed a CVE. 17 patients died during follow-up.

CONCLUSION: Coronary calcification on non ECG-gated chest CTs was detected in 72.6 % of patients, cardiac assessment was feasible in nearly half of these patients. Only patients with a CAD-RADS≥3 developed CVE, therefore the CAD-RADS may help identify and guide patients at risk of future CVE.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Eijsvoogel NG, Hendriks BMF, Martens B, et al. The performance of non-ECG gated chest CT for cardiac assessment - The cardiac pathologies in chest CT (CaPaCT) study. Eur J Radiol. 2020. PMID: 32650129. doi:10.1016/j.ejrad.2020.109151

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。