扩散加权MRI与18F氟脱氧葡萄糖PET/CT在头颈部鳞状细胞癌(化疗)放疗后检测残留或复发肿瘤及勾画局部扩散范围的比较
纳入25例头颈部鳞状细胞癌(化疗)放疗后行手术挽救的患者,以术后病理为金标准,比较DW-MRI与18F-FDG PET/CT检测残留或复发肿瘤及局部浸润的效能。两者检测残留或复发肿瘤的敏感度均为92%(23/25);MRI检测神经周围扩散的敏感度62%(5/8),PET/CT未检出任何神经周围扩散病例;MRI检测肌肉浸润的敏感度75%(9/12)优于PET/CT的58%(7/12)。
要点
- DW-MRI与18F-FDG PET/CT检测残留或复发肿瘤的敏感度均为92%(23/25)。
- MRI检测神经周围扩散敏感度62%(5/8),PET/CT未检出任何神经周围扩散病例。
- MRI检测肌肉浸润敏感度75%(9/12)优于PET/CT的58%(7/12)。
诊断标准与关键数值
- DW-MRI检测残留或复发肿瘤的敏感度为92%(23/25)。
- 18F-FDG PET/CT检测残留或复发肿瘤的敏感度为92%(23/25)。
- MRI检测神经周围扩散的敏感度62%(5/8)、特异度88%(15/17)、阳性预测值71%(5/7)、阴性预测值83%(15/18)。
- PET/CT未检出任何神经周围扩散病例。
- MRI检测肌肉浸润的敏感度75%(9/12)、特异度77%(10/13)、阳性预测值75%(9/12)、阴性预测值77%(10/13)。
临床应用与阅片要点
- 作者结论指出DW-MRI与18F-FDG PET/CT对残留或复发肿瘤检出率相同,MRI检测局部神经周围扩散敏感度更高、检测肌肉浸润准确度更好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the diagnostic accuracy of diffusion-weighted magnetic resonance imaging (DW-MRI) and fluorine 18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) in detection of residual or recurrent tumors and their local extension in patients with head and neck squamous cell carcinoma after treatment with (chemo) radiotherapy (CRT).
METHOD: Twenty-five patients (17 men, 8 women, median age 64 years, range 49-79) who underwent surgical salvage for residual or recurrent tumors after CRT were included. The histopathologic analysis after the surgical salvage served as the gold standard.
RESULTS: Both DW-MRI and 18F-FDG PET/CT had a sensitivity of 92 % (23/25) in the detection of residual or recurrent tumors. MRI had a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting perineural spread of 62 % (5/8), 88 % (15/17), 71 % (5/7) and 83 % (15/18), respectively; in comparison, PET/CT did not detect any cases of perineural spread. The sensitivity, specificity, PPV and NPV of MRI in detecting muscle infiltration was 75 % (9/12), 77 % (10/13), 75 % (9/12) and 77 % (10/13) respectively, while the values for 18F-FDG PET/CT were 58 % (7/12), 69 % (9/13), 64 % (7/11) and 64 % (9/14).
CONCLUSIONS: DW-MRI- and 18F-FDG PET/CT-imaging have an identical detection rate of residual or recurrent tumors after (chemo) radiotherapy. MRI has a higher sensitivity in detecting local perineural spread, has a better accuracy in the detection of muscle infiltration and more accurately correlates the lesion size to the histopathologic specimen.
引用
- Schroeder C, Lee JH, Tetzner U, et al. Comparison of diffusion-weighted MR imaging and 18F Fluorodeoxyglucose PET/CT in detection of residual or recurrent tumors and delineation of their local spread after (chemo) radiotherapy for head and neck squamous cell carcinoma. Eur J Radiol. 2020. PMID: 32652403. doi:10.1016/j.ejrad.2020.109157
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。