文献速递头颈神经MR

体素内不相干运动扩散加权成像鉴别良恶性咽后淋巴结

Intravoxel incoherent motion diffusion-weighted imaging for discrimination of benign and malignant retropharyngeal nodes.
PubMed 文献 · Neuroradiology · 2020-07-16

本研究对30例新诊断转移性鼻咽癌患者和30例血浆EBV-DNA升高但无鼻咽癌者的咽后淋巴结行14个b值的IVIM DWI,比较直方图参数。良性咽后淋巴结ADCmean和Dmean低于恶性转移性淋巴结,D*mean高于恶性转移性淋巴结,f无差异;Dmean的AUC最高为0.800,但IVIM较常规DWI无显著优势。

要点

  • 良性咽后淋巴结ADCmean和Dmean低于恶性转移性淋巴结,D*mean高于恶性转移性淋巴结。
  • Dmean鉴别良恶性咽后淋巴结的AUC最高为0.800,但与其他参数AUC无统计学差异。
  • IVIM灌注分数f在良恶性咽后淋巴结间无差异(p=0.204至0.301)。

核心结论

  • EBV-DNA升高者的良性咽后淋巴结较鼻咽癌恶性转移性淋巴结弥散受限更明显。
  • IVIM在鉴别良恶性咽后淋巴结方面较常规DWI无显著优势。

研究设计与样本

  • 研究纳入30例新诊断转移性鼻咽癌患者和30例血浆EBV-DNA升高但无鼻咽癌者(来自基于EBV的鼻咽癌筛查项目)。
  • 对咽后淋巴结行14个b值的IVIM DWI,比较纯扩散系数D、伪扩散系数D*、灌注体积分数f和表观扩散系数ADC的直方图测量值。
  • 采用Mann-Whitney U检验比较两组,对显著参数行ROC分析计算AUC并用DeLong检验比较。

诊断标准与关键数值

  • 良性咽后淋巴结ADCmean为0.73×10-3 mm2/s,恶性转移性淋巴结为0.82×10-3 mm2/s(p<0.05)。
  • 良性咽后淋巴结Dmean为0.60×10-3 mm2/s,恶性转移性淋巴结为0.71×10-3 mm2/s(p<0.05)。
  • 良性咽后淋巴结D*mean为35.21×10-3 mm2/s,恶性转移性淋巴结为28.66×10-3 mm2/s(p<0.05)。
  • f测量值在两组间无差异(p=0.204至0.301)。
  • Dmean的AUC最高为0.800,但与其他参数AUC比较无统计学差异(p=0.148至0.991)。

临床应用与阅片要点

  • 良性咽后淋巴结在EBV-DNA升高者中可表现为ADCmean和Dmean低于鼻咽癌转移性淋巴结。
  • IVIM参数Dmean的AUC为0.800,但未显著优于其他参数。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Anatomical imaging criteria for the diagnosis of malignant head and neck nodes may not always be reliable. This study aimed to evaluate the diagnostic value of conventional diffusion-weighted imaging (DWI) and intravoxel incoherent motion (IVIM) DWI in discriminating benign and malignant metastatic retropharyngeal nodes (RPNs).

METHODS: IVIM DWI using 14 b-values was performed on RPNs of 30 patients with newly diagnosed metastatic nasopharyngeal carcinoma (NPC) and 30 patients with elevated plasma Epstein-Barr virus (EBV)-DNA without NPC who were part of an EBV-based NPC screening program. Histogram measurements of the two groups were compared for pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion volume fraction (f) and apparent diffusion coefficient (ADC) using the Mann-Whitney U test. Area under the curves (AUCs) of significant measurements were calculated from receiver-operating characteristics analysis and compared using the DeLong test.

RESULTS: Compared with metastatic RPNs, benign RPNs had lower ADCmean (0.73 vs 0.82 × 10-3 mm2/s) and Dmean (0.60 vs 0.71 × 10-3 mm2/s) and a higher D*mean (35.21 vs 28.66 × 10-3 mm2/s) (all p < 0.05). There was no difference in the f measurements between the two groups (p = 0.204 to 0.301). Dmean achieved the highest AUC of 0.800, but this was not statistically better than the AUCs of the other parameters (p = 0.148 to 0.991).

CONCLUSION: Benign RPNs in patients with EBV-DNA showed greater restriction of diffusion compared with malignant metastatic RPNs from NPC. IVIM did not show a significant advantage over conventional DWI in discriminating benign and malignant nodes.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. So TY, Ai QH, Lam WKJ, et al. Intravoxel incoherent motion diffusion-weighted imaging for discrimination of benign and malignant retropharyngeal nodes. Neuroradiology. 2020. PMID: 32676831. doi:10.1007/s00234-020-02494-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。