文献速递神经儿科影像MR

儿童结节性硬化症随访中室管膜下巨细胞星形细胞瘤的磁共振成像诊断:是否应始终使用对比增强?

Magnetic resonance imaging diagnosis of subependymal giant cell astrocytomas in follow-up of children with tuberous sclerosis complex: should we always use contrast enhancement?
PubMed 文献 · Pediatr Radiol · 2020-07-15

该回顾性单中心研究纳入35例结节性硬化症患儿,比较非增强与增强MRI鉴别室管膜下巨细胞星形细胞瘤(SEGA)与室管膜下结节的诊断效能。非增强MRI诊断SEGA的敏感度为75%–100%、特异度为94%–100%,与增强MRI准确性相似,假阳性与假阴性病例数差异从未超过1例,对TSC患者系统使用钆对比剂的做法提出质疑。

要点

  • 非增强MRI诊断SEGA的敏感度75%–100%、特异度94%–100%,与增强MRI准确性相似。
  • 结节>10 mm、位于室间孔附近、脑积水及两次连续MRI间变化与SEGA诊断显著相关(所有P值<0.05)。
  • 非增强与增强序列的观察者间及观察者内一致性均极好(kappa分别为0.85–1和0.81–0.93)。

关键影像表现/征象

  • 结节大小>10 mm、位于室间孔附近、脑积水及两次连续MRI扫描间的变化与SEGA诊断显著相关,对3名阅片者均如此(所有P值<0.05)。
  • 非增强与增强MRI之间假阳性及假阴性患者数的差异从未超过1例。

诊断标准与关键数值

  • 非增强MRI诊断SEGA的敏感度为75%–100%,特异度为94%–100%。
  • 非增强与增强MRI序列的观察者间一致性kappa=0.85–1,观察者内一致性kappa=0.81–0.93。

临床应用与阅片要点

  • 在TSC患者随访中,非增强MRI序列对SEGA的诊断效能与增强MRI相当,可减少钆对比剂重复使用。
  • 阅片时关注结节大小>10 mm、位于室间孔附近、脑积水及两次连续MRI间的变化,这些征象与SEGA诊断显著相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Subependymal giant cell astrocytomas (SEGAs) arise in 10-26% of tuberous sclerosis complex (TSC) patients. SEGAs cause obstructive hydrocephalus and increase morbi-mortality. It is recommended that TSC patients be followed with contrast enhanced magnetic resonance imaging (CE-MRI), but repetitive use of gadolinium-based contrast-agents (GBCAs) may cause organ deposits.

OBJECTIVE: To compare the diagnostic performances of non-CE- and CE-MRI to differentiate SEGAs from subependymal nodules in TSC patients during follow-up.

MATERIALS AND METHODS: Thirty-five TSC patients (median age: 2.4 years) were enrolled in this retrospective single-center study from September 2007 to January 2019. Inclusion criteria were a certain diagnosis of TSC and at least three follow-up brain MRIs with GBCA injection. Two consecutive MRI scans per patient were selected and anonymized. Three radiologists performed a blinded review of non-enhanced and enhanced MRI sequences during different sessions. The diagnostic performances were compared (sensitivity, specificity, positive/negative predictive values, accuracy, inter/intra-observer agreements).

RESULTS: The accuracies for detecting SEGAs were good and similar between the non-enhanced and enhanced MRI sequences. The sensitivity and specificity of non-CE-MRI to diagnose SEGA ranged from 75% to 100% and from 94% to 100%, respectively. The differences in numbers of false-positive and false-negative patients between non-CE- and CE-MRI never exceeded one case. Nodules size >10 mm, location near the Monro foramen, hydrocephalus and modifications between two consecutive MRI scans were significantly associated with the diagnosis of SEGA for the three readers (all P-values <0.05). Inter- and intra-observer agreements were also excellent for non-enhanced and enhanced MRI sequences (kappa=0.85-1 and 0.81-0.93, respectively).

CONCLUSION: The performances of non-enhanced and enhanced MRI sequences are comparable for detecting SEGAs, questioning the need for systematic GBCA injections for TSC patients.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Gaillard AL, Crombé A, Jecko V, et al. Magnetic resonance imaging diagnosis of subependymal giant cell astrocytomas in follow-up of children with tuberous sclerosis complex: should we always use contrast enhancement? Pediatr Radiol. 2020. PMID: 32671416. doi:10.1007/s00247-020-04707-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。