联合幕上动脉与幕下静脉的修订版CT血管造影评分在脑死亡确认中的诊断准确性
本研究回顾性纳入69例符合临床脑死亡标准并接受CTA的成人患者,由两名盲法神经放射科医生比较4分法与三种纳入上岩静脉的修订评分。Toulouse评分(上岩静脉+大脑中动脉)阳性预测值100%,观察者一致性0.77,误分类率最低3.03%,敏感度86.4%接近4分法的89.4%,在去骨瓣减压亚组结果相似。
要点
- Toulouse评分(上岩静脉+大脑中动脉)与4分法相比阳性预测值100%,误分类率最低3.03%。
- Toulouse评分敏感度86.4%接近4分法89.4%(p<0.001),观察者一致性0.77为中等程度。
- 去骨瓣减压患者亚组中Toulouse评分结果与总体相似。
关键影像表现/征象
- Toulouse评分评估上岩静脉和大脑中动脉的非充盈。
- 静脉评分评估上岩静脉和大脑内静脉的非充盈。
- 7分评分评估上岩静脉、大脑中动脉、大脑内静脉和基底动脉的非充盈。
诊断标准与关键数值
- 以4分法为参考时,Toulouse评分阳性预测值100%,观察者一致性0.77(0.53; 1),误分类率3.03%。
- Toulouse评分敏感度86.4%(75.7; 93.6),4分法敏感度89.4%(79.4; 95.6),p<0.001。
- 4分法确认脑死亡59例(89.4%)。
临床应用与阅片要点
- 阅片时可关注上岩静脉的非充盈,Toulouse评分结合上岩静脉和大脑中动脉。
- 在去骨瓣减压患者中Toulouse评分结果与总体相似,可作为参考。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The 4-point score is the corner stone of brain death (BD) confirmation using computed tomography angiography (CTA). We hypothesized that considering the superior petrosal veins (SPVs) may improve CTA diagnosis performance in BD setting. We aimed at comparing the diagnosis performance of three revised CTA scores including SPVs and the 4-point score in the confirmation of BD.
METHODS: In this retrospective study, 69 consecutive adult-patients admitted in a French University Hospital meeting clinical brain death criteria and receiving at least one CTA were included. CTA images were reviewed by two blinded neuroradiologists. A first analysis compared the 4-point score, considered as the reference and three non-opacification scores: a "Toulouse score" including SPVs and middle cerebral arteries, a "venous score" including SPVs and internal cerebral veins and a "7-score" including all these vessels and the basilar artery. Psychometric tools, observer agreement and misclassification rates were assessed. A second analysis considered clinical examination as the reference.
RESULTS: Brain death was confirmed by the 4-score in 59 cases (89.4 %). When compared to the 4-score, the Toulouse score displayed a 100 % positive predictive value, a substantial observer agreement (0.77 [0.53; 1]) and the least misclassification rate (3.03 %). Results were similar in the craniectomy subgroup. The Toulouse score was the only revised test that combined a sensitivity close to that of the 4-score (86.4 % [75.7; 93.6] and 89.4 % [79.4; 95.6], p-value < 0.001, respectively) and a substantial observer agreement.
CONCLUSIONS: A score including SPVs and middle cerebral arteries is a valid method for BD confirmation using CTA even in patients receiving craniectomy.
引用
- Srairi M, Meluchova Z, Paoletti M, et al. Diagnostic accuracy of a revised computed tomography angiography score for brain death confirmation, combining supra-tentorial arteries and infra-tentorial veins. Eur J Radiol. 2020. PMID: 32619753. doi:10.1016/j.ejrad.2020.109132
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。