孕11周至13周6天常规超声筛查中的胎儿开放性及闭合性脊柱裂
本回顾性研究基于2008至2015年一家三级中心的前瞻性数据库,分析53,349例妊娠中诊断的24例脊柱裂,其中7例开放性脊柱裂和7例闭合性脊柱裂纳入分析。孕早期常规超声对开放性脊柱裂的检出率为100%(7/7),对闭合性脊柱裂为28.5%(2/7);后脑异常表现使8例在孕早期被高度怀疑脊柱裂,其中3例为假阳性。小脑延髓池消失对开放性脊柱裂敏感性最高但特异性低,作者结论为孕早期常规超声筛查开放性脊柱裂敏感性高,小脑延髓池可能是最敏感的颅内征象。
要点
- 孕早期常规超声对开放性脊柱裂检出率100%(7/7),对闭合性脊柱裂仅28.5%(2/7)。
- 后脑异常表现使8例在孕早期被高度怀疑脊柱裂,其中3例为假阳性。
- 小脑延髓池消失对开放性脊柱裂敏感性最高但特异性低。
核心结论
- 孕早期常规超声筛查开放性脊柱裂敏感性高,小脑延髓池可能是最敏感的颅内征象。
研究设计与样本
- 回顾性研究,为对前瞻性收集数据库的回顾,纳入2008至2015年一家三级中心诊断的所有脊柱裂病例。
- 共诊断24例脊柱裂,来自53,349例妊娠;排除10例体蒂异常、颅脊柱裂或无脑脊膜膨出后,分析7例开放性脊柱裂和7例闭合性脊柱裂。
- 所有产前诊断的脊柱裂病例均经出生或尸检确认。
关键影像表现/征象
- 8例因后脑异常表现在孕早期被高度怀疑脊柱裂,其中3例为假阳性。
- 2例孤立性开放性脊柱裂有孕早期颅内征象。
- 2例开放性脊柱裂无法辨认颅内透明层和小脑延髓池的标志,4例显示颅内透明层正常伴小脑延髓池消失。
- 除2例外,所有闭合性脊柱裂病例后脑正常。
诊断标准与关键数值
- 孕早期检出率:开放性脊柱裂100%(7/7),闭合性脊柱裂28.5%(2/7)。
- 小脑延髓池消失对开放性脊柱裂敏感性最高但特异性低。
临床应用与阅片要点
- 孕早期常规超声筛查中应评估后脑结构,后脑异常表现可提示脊柱裂可能。
- 小脑延髓池消失对开放性脊柱裂敏感性最高但特异性低,需注意假阳性。
- 闭合性脊柱裂在孕早期检出率低(28.5%),多数后脑正常。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to determine the sensitivity of a first-trimester routine scan in detecting spina bifida (SB) and evaluating the first-trimester intracranial signs.
METHODS: This retrospective study was a review of a prospectively collected database. All cases of SB diagnosed in a tertiary center from 2008 to 2015 were identified. The ultrasound images and medical records were reviewed. All cases of SB diagnosed prenatally were confirmed at birth or autopsy.
RESULTS: A total of 24 cases of SB were diagnosed from 53,349 pregnancy cases. Except for 10 cases with a body stalk anomaly, craniorachischisis, or iniencephaly, 7 cases with open spina bifida (OSB) and 7 cases with closed spina bifida (CSB) were analyzed. The first-trimester detection rates were 100% (7 of 7) for OSB and 28.5% (2 of 7) for CSB. Eight cases were highly suspected of SB in the first trimester because of an abnormal appearance of the posterior brain; 3 were false-positive cases. Two isolated cases of OSB had first-trimester intracranial signs. An obliterated cisterna magna (CM) showed the highest sensitivity for OSB but low specificity. Two cases of OSB had no discernible landmark of intracranial translucency and the CM, and 4 showed normal intracranial translucency with an obliterated CM. All CSB cases were coupled with a normal hind brain except for 2 cases.
CONCLUSIONS: A first-trimester routine scan has high sensitivity in screening for OSB. The CM may be the most sensitive intracranial sign.
引用
- Liao Y, Wen H, Luo G, et al. Fetal Open and Closed Spina Bifida on a Routine Scan at 11 Weeks to 13 Weeks 6 Days. J Ultrasound Med. 2020. PMID: 32691861. doi:10.1002/jum.15392
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。